Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT

被引:21
作者
Mergen, Victor [1 ]
Ghouse, Sadaf [1 ]
Sartoretti, Thomas [1 ]
Manka, Robert [1 ,2 ]
Euler, Andre [1 ]
Kasel, Albert M. [2 ]
Alkadhi, Hatem [1 ]
Eberhard, Matthias [1 ,3 ]
机构
[1] Univ Zurich, Intervent Radiol Univ Hosp Zurich, Inst Diagnost, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Univ Heart Ctr Univ Hosp Zurich, Dept Cardiol, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Spitaler fmi AG, Inst Radiol, Unterseen, Switzerland
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2023年 / 5卷 / 03期
关键词
Coronary Arteries; Aortic Valve; Mitral Valve; Aortic Stenosis; Calci-fications; Photon-counting Detector CT; CORONARY-ARTERY CALCIUM; ALL-CAUSE MORTALITY; RECONSTRUCTION; FEASIBILITY; ANGIOGRAPHY; ALGORITHM;
D O I
10.1148/ryct.220307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images.Materials and Methods: This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted & kappa; analysis.Results: Ninety patients were included (mean age, 80 years & PLUSMN; 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (& kappa; = 0.974) and on VNC images at 70 keV for CAC (& kappa; = 0.967).Conclusion: VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.
引用
收藏
页数:9
相关论文
共 31 条
  • [1] SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee Endorsed by the North American Society for Cardiovascular Imaging (NASCI)
    Abbara, Suhny
    Blanke, Philipp
    Maroules, Christopher D.
    Cheezum, Michael
    Choi, Andrew D.
    Han, B. Kelly
    Marwan, Mohamed
    Naoum, Chris
    Norgaard, Bjarne L.
    Rubinshtein, Ronen
    Schoenhagen, Paul
    Villines, Todd
    Leipsic, Jonathon
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) : 435 - 449
  • [2] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [3] Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom
    Allmendinger, Thomas
    Nowak, Tristan
    Flohr, Thomas
    Klotz, Ernst
    Hagenauer, Junia
    Alkadhi, Hatem
    Schmidt, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 399 - 405
  • [4] Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
  • [5] Mitral Annulus Calcium Score An Independent Predictor of New Conduction System Abnormalities in Patients After Transcatheter Aortic Valve Implantation
    Brodov, Yafim
    Konen, Eli
    Di Segni, Mattia
    Samoocha, David
    Chernomordik, Fernando
    Barbash, Israel
    Regev, Ehud
    Raanani, Ehud
    Guetta, Victor
    Segev, Amit
    Fefer, Paul
    Glikson, Michael
    Goitein, Orly
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (01)
  • [6] Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection
    Caruso, Damiano
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Felmly, Lloyd M.
    Varga-Szemes, Akos
    Mangold, Stefanie
    Canstein, Christian
    Allmendinger, Thomas
    Fuller, Stephen R.
    Laghi, Andrea
    Wichmann, Julian L.
    [J]. ACADEMIC RADIOLOGY, 2016, 23 (12) : 1480 - 1489
  • [7] Aortic valve calcification predicts all-cause mortality independent of coronary calcification and severe stenosis
    Christensen, Jared L.
    Tan, Sydney
    Chung, Hojune E.
    Ghosalkar, Dhairyasheel S.
    Qureshi, Reema
    Chu, Alice
    Yu, Wenzheng
    Berus, Joshua
    Shah, Nishant R.
    Wu, Wen-Chih
    Chun, Hyung
    Aikawa, Elena
    Choudhary, Gaurav
    Morrison, Alan R.
    [J]. ATHEROSCLEROSIS, 2020, 307 : 16 - 20
  • [8] Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans
    Eberhard, Matthias
    Mergen, Victor
    Higashigaito, Kai
    Allmendinger, Thomas
    Manka, Robert
    Flohr, Thomas
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    [J]. DIAGNOSTICS, 2021, 11 (09)
  • [9] Incremental Prognostic Value of Coronary Artery Calcium Score for Predicting All-Cause Mortality after Transcatheter Aortic Valve Replacement
    Eberhard, Matthias
    Hinzpeter, Ricarda
    Schoenenberger, Amadea L. N.
    Euler, Andre
    Kuzo, Nazar
    Reeve, Kelly
    Stahli, Barbara E.
    Kasel, Albert M.
    Manka, Robert
    Tanner, Felix C.
    Alkadhi, Hatem
    [J]. RADIOLOGY, 2021, 301 (01) : 105 - 112
  • [10] Coronary Computed Tomography Angiography-Based Calcium Scoring In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System
    Emrich, Tilman
    Aquino, Gilberto
    Schoepf, U. Joseph
    Braun, Franziska M.
    Risch, Franka
    Bette, Stefanie J.
    Woznicki, Piotr
    Decker, Josua A.
    O'Doherty, Jim
    Brandt, Verena
    Allmendinger, Thomas
    Nowak, Tristan
    Schmidt, Bernhard
    Flohr, Thomas
    Kroencke, Thomas J.
    Scheurig-Muenkler, Christian
    Varga-Szemes, Akos
    Schwarz, Florian
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (08) : 536 - 543