Reliability of shear-wave elastography in assessing the stiffness of the nuchal fascia and the thickness of upper cervical muscles

被引:2
作者
Liao, Lin-Rong [1 ]
Pan, Hong-Hua [2 ]
Diao, Ying-Xiu [1 ,3 ]
Xie, Yi [4 ]
Liao, Man-Xia [5 ]
Xie, Yu-Hua [6 ]
机构
[1] Guangdong Med Univ, Dongguan Affiliated Hosp 1, Rehabil Med Ctr, Dongguan 523000, Peoples R China
[2] Jiangsu Univ, Affiliated Yixing Hosp, Dept Gastroenterol, Wuxi 214000, Peoples R China
[3] Gannan Med Univ, Sch Rehabil Med, Ganzhou 341000, Peoples R China
[4] Anqing Normal Univ, Anqing 246000, Peoples R China
[5] Jixing JORU Rehabil Hosp, Dept Rehabil, Yixing 214000, Peoples R China
[6] Gannan Healthcare Vocat Coll, Ganzhou 341000, Jiangxi, Peoples R China
关键词
Reliability; Diagnostic imaging; Shear-wave elastography; Nuchal fascia; Cervical muscle; NECK PAIN; ULTRASOUND; SIZE; CONTRACTION; FLEXOR; ANGLES; HEAD;
D O I
10.1016/j.medengphy.2023.104039
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To determine the reliability of shear-wave elastography (SWE)in assessing the stiffness of the nuchal fascia and the thickness of upper cervical muscles in neutral head posture (NHP) or forward head posture (FHP).Methods: Sixteen healthy adults (mean age: 21.69 +/- 1.01years, 9 females) were included. SWE mode was chosen to measure the nuchal fascia shear modulus and muscle thickness was measured in B-mode. Measurements were collected by two independent investigators on two different days. The intraclass correlation coefficient (ICC) was used to measure the relative reliability, and the standard error of measurement (SEM) were used to measure the absolute reliability.Results: Intra-rater (ICC = 0.63-0.89) and inter-rater (ICC = 00.54-0.82) reliability for the nuchal fascia shear modulus were moderate to excellent. Intra-rater (ICC = 00.64-0.96) and inter-rater (ICC = 00.48-0.86) reliability for upper cervical muscles thickness were moderate to excellent. The SEM percentage oscillated from 3.27% to 13.55%. There were significant differences(P < 0.05) between NHP and FHP on nuchal fascia shear modulus, right side splenius capitis muscle thickness and left side semispinalis capitis muscle thickness, but no significant differences(P > 0.05) were observed between the right and left sides. The upper cervical muscles thickness of males was significantly thicker(P < 0.01) than females while no significant differences were observed (P > 0.05) on the nuchal fascia shear modulus.Conclusions: Ultrasound-based SWE may be a reliable tool for assessing the stiffness of the nuchal fascia and the thickness of upper cervical muscles in clinical practice.
引用
收藏
页数:17
相关论文
共 44 条
[1]  
Bhatia K, 2012, ULTRASCHALL MED, V33, P463, DOI [10.1055/s-0032-1325330, 10.1055/s-0032-1325428]
[2]   Influence of thoracolumbar fascia stretching on lumbar back muscle stiffness: A supersonic shear wave elastography approach [J].
Blain, Maxime ;
Bedretdinova, Dina ;
Bellin, Marie-France ;
Rocher, Laurence ;
Gagey, Olivier ;
Soubeyrand, Marc ;
Creze, Maud .
CLINICAL ANATOMY, 2019, 32 (01) :73-80
[3]   Comparison of cervical muscle thickness between asymptomatic women with and without forward head posture [J].
Bokaee, Fateme ;
Rezasoltani, Asghar ;
Manshadi, Farideh D. ;
Naimi, Sedigheh S. ;
Baghban, Alireza A. ;
Azimi, Hadi .
BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2017, 21 (03) :206-211
[4]   Clinical and symptomatological reflections: the fascial system [J].
Bordoni, Bruno ;
Zanier, Emiliano .
JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2014, 7 :401-411
[5]   Postural stability of the head in response to slowly imposed, small elastic loads [J].
Chan, R ;
Rogers, DK ;
McCloskey, DI .
NEUROSCIENCE LETTERS, 1996, 214 (2-3) :205-207
[6]   Reliability of shear-wave elastography in assessing thoracolumbar fascia elasticity in healthy male [J].
Chen, Baizhen ;
Zhao, Hongzhou ;
Liao, Linrong ;
Zhang, Zhijie ;
Liu, Chunlong .
SCIENTIFIC REPORTS, 2020, 10 (01)
[7]   Analysis of influencing factors of shear wave elastography of the superficial tissue: A phantom study [J].
Chen, Qiyang ;
Shi, Baixue ;
Zheng, Yang ;
Hu, Xiangdong .
FRONTIERS IN MEDICINE, 2022, 9
[8]   Investigation of the Differential Contributions of Superficial and Deep Muscles on Cervical Spinal Loads with Changing Head Postures [J].
Cheng, Chih-Hsiu ;
Chien, Andy ;
Hsu, Wei-Li ;
Chen, Carl Pai-Chu ;
Cheng, Hsin-Yi Kathy .
PLOS ONE, 2016, 11 (03)
[9]   Posture-related stiffness mapping of paraspinal muscles [J].
Creze, Maud ;
Bedretdinova, Dina ;
Soubeyrand, Marc ;
Rocher, Laurence ;
Gennisson, Jean-Luc ;
Gagey, Olivier ;
Maitre, Xavier ;
Bellin, Marie-France .
JOURNAL OF ANATOMY, 2019, 234 (06) :787-799
[10]   Shear wave sonoelastography of skeletal muscle: basic principles, biomechanical concepts, clinical applications, and future perspectives [J].
Creze, Maud ;
Nordez, Antoine ;
Soubeyrand, Marc ;
Rocher, Laurence ;
Maitre, Xavier ;
Bellin, Marie-France .
SKELETAL RADIOLOGY, 2018, 47 (04) :457-471