Numerical study on performance of hybrid mechanical draft wet cooling tower

被引:11
作者
Deng, Weipeng [1 ]
Sun, Fengzhong [1 ]
Chen, Kun [1 ]
Zhang, Xiaoyu [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Peoples R China
关键词
Hybrid MCT; Thermal performance; Plume abatement; Water saving rate; Numerical simulation; CROSSWIND; AIR; TEMPERATURE; ABATEMENT; RETROFIT; SYSTEM; PLUME; WATER;
D O I
10.1016/j.ijheatmasstransfer.2022.123574
中图分类号
O414.1 [热力学];
学科分类号
摘要
To explore the operation mechanism of the hybrid mechanical draft wet cooling tower (hybrid MCT), a 3D model of the hybrid MCT is established. The plume, water saving, and cooling capacity of the hybrid MCT are discussed. The ambient dry bulb temperature, relative humidity, circulating water temperature, and circulating water flow rate are taken as the main variables. Results that the ambient dry bulb temperature and circulating water temperature have the larger impact on the plume abatement and water saving rate, and the relative humidity and circulating water flow rate have relatively small impact. As the ratio of circulating water flow rate in the dry part increases, the water saving rate and cooling capacity of hybrid MCT are enhanced. However, when the ratio of circulating water flow rate in the dry part exceeds 0.4, the variation of water saving rate is not obvious. Based on satisfied plume abatement, by adjusting the airflow resistance in the dry part, the water temperature drop of hybrid MCT can be increased by 0.4 degrees C.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] An exploratory research on performance improvement of super-large natural draft wet cooling tower based on the reconstructed dry-wet hybrid rain zone
    Zhang, Zhengqing
    Gao, Ming
    Dang, Zhigang
    He, Suoying
    Sun, Fengzhong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 142
  • [32] Numerical study on the cooling performance of dry cooling tower with vertical two-pass column radiators under crosswind
    Zhao, Y. B.
    Long, Guoqing
    Sun, Fengzhong
    Li, Yan
    Zhang, Cuijiao
    APPLIED THERMAL ENGINEERING, 2015, 75 : 1106 - 1117
  • [33] Numerical Investigation on the Influence of Mechanical Draft Wet-Cooling Towers on the Cooling Performance of Air-Cooled Condenser with Complex Building Environment
    Fan, Jun
    Dong, Haotian
    Xu, Xiangyang
    Teng, De
    Yan, Bo
    Zhao, Yuanbin
    ENERGIES, 2019, 12 (23)
  • [34] A novel approach for performance assessment of mechanical draft wet cooling towers
    Naik, B. Kiran
    Muthukumar, P.
    APPLIED THERMAL ENGINEERING, 2017, 121 : 14 - 26
  • [35] Impact of Crosswind on Steady-State and Dynamic Performance of Natural Draft Dry Cooling Tower Group: A Numerical Analysis
    Jiang, Xuhui
    Zhang, Xi
    Wang, Song
    Wang, Ruiqiong
    Zou, Peng
    Lu, Jingzhou
    Li, Xiaoxiao
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 (01): : 193 - 216
  • [36] The cooling performance of a natural draft dry cooling tower under crosswind and an enclosure approach to cooling efficiency enhancement
    Wang, Weiliang
    Zhang, Hai
    Liu, Pei
    Li, Zheng
    Lv, Junfu
    Ni, Weidou
    APPLIED ENERGY, 2017, 186 : 336 - 346
  • [38] Numerical simulation of thermal performance for super large-scale wet cooling tower equipped with an axial fan
    Dang, Zhigang
    Zhang, Zhengqing
    Gao, Ming
    He, Suoying
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 220 - 234
  • [39] Comparative study on the thermal characteristics of natural draft wet cooling tower with internal and external auxiliary fans
    Chen, Xuehong
    Sun, Fengzhong
    Xia, Lijiang
    Song, Xu
    Zhang, Xiaoyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [40] New method to decrease the air recirculation of mechanical draft wet cooling tower group by increasing height of fan duct
    Deng, Weipeng
    Sun, Fengzhong
    Chen, Kun
    Zhang, Xiaoyu
    APPLIED THERMAL ENGINEERING, 2023, 219