Robust Novel Indicator To Distinguish between an Inter-Turn Short Circuit Fault and Load Unbalance in PMSG

被引:8
作者
Bahloul, Issam [1 ]
Bouzid, Monia Ben Khader [1 ]
El Khil, Sejir Khojet [1 ]
Champenois, Gerard [2 ]
机构
[1] Univ Tunis El Manar, ENIT LSE, LR11ES15, BP 37, Tunis 1002, Tunisia
[2] Univ Poitiers, ISAE ENSMA Poitiers LIAS, F-86073 Poitiers, France
关键词
Fault detection; fault indicator; inter-turn short circuit fault; load unbalance; negative sequence current; negative sequence voltage; permanentmagnet synchronous generator; phase shift; positive sequence current; positive sequence voltage; MAGNET SYNCHRONOUS MACHINES; DIAGNOSIS;
D O I
10.1109/TIA.2023.3236898
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the aim to increase the reliability of the permanent magnet synchronous generator (PMSG), this paper proposes an efficient symmetrical component-based method to detect and accurately diagnose an incipient inter-turn short circuit (ITSC) fault in the PMSG without any confusion with a load unbalance. In fact, the existence of a negative sequence voltage component in the PMSG may be due to ITSC faults or to load unbalance, which creates confusion and affects the accuracy of the fault detection. To address this issue, this paper proposes a novel robust indicator capable of distinguishing without any ambiguity, an ITSC fault from a load unbalance in the machine. Hence, the objective of this paper is to demonstrate the behavior and the effectiveness of the novel indicator able to discriminate between the two operating modes, through original thorough analytical and simulation studies, validated experimentally on a real PMSG.
引用
收藏
页码:3200 / 3209
页数:10
相关论文
共 45 条
[1]  
Aubert B, 2013, 2013 9TH IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), P329, DOI 10.1109/DEMPED.2013.6645736
[2]  
Aubert B., 2014, Acta IMEKO, V3, P4, DOI [10.21014/actaimeko.v3i4.146, DOI 10.21014/ACTAIMEKO.V3I4.146]
[3]   Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators [J].
Aubert, Brice ;
Regnier, Jeremi ;
Caux, Stephane ;
Alejo, Dominique .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) :1921-1930
[4]  
Barrera M., 2021, El Periplo Sustentable, P56
[5]   The Initial Temperature Rise in a Permanent Magnet Synchronous Generator as a Tool in the Detection of Stator Inter-Turn Short-Circuits [J].
Barrett, Michael .
2020 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2020,
[6]   Reliable and Robust Inter-turn Short-Circuit Fault Detection in PMSG without confusion with Healthy Operating Under Load Unbalance [J].
Bouzid, M. ;
Bahloul, I. ;
El Khil, S. Khojet .
2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, :372-378
[7]   Efficient Simplified Physical Faulty Model of a Permanent Magnet Synchronous Generator Dedicated to the Stator Fault Diagnosis Part I: Faulty Model Conception [J].
Bouzid, Monia Ben Khader ;
Champenois, Gerard ;
Maalaoui, Ahmed ;
Tnani, Slim .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :2752-2761
[8]   An Efficient Simplified Physical Faulty Model of a Permanent Magnet Synchronous Generator Dedicated to Stator Fault Diagnosis Part II: Automatic Stator Fault Diagnosis [J].
Bouzid, Monia Ben Khader ;
Champenois, Gerard .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :2762-2771
[9]   Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review [J].
Chen, Yong ;
Liang, Siyuan ;
Li, Wanfu ;
Liang, Hong ;
Wang, Chengdong .
APPLIED SCIENCES-BASEL, 2019, 9 (10)
[10]   Fault Diagnosis Techniques for Permanent Magnet AC Machine and Drives-A Review of Current State of the Art [J].
Choi, Seungdeog ;
Haque, Moinul Shahidul ;
Bin Tarek, Md Tawhid ;
Mulpuri, Vamsi ;
Duan, Yao ;
Das, Sanjoy ;
Garg, Vijay ;
Ionel, Dan M. ;
Masrur, M. Abul ;
Mirafzal, Behrooz ;
Toliyat, Hamid A. .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2018, 4 (02) :444-463