Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs
被引:3
|
作者:
Kim, Kisoo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St,S341, San Francisco, CA 94115 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
Kim, Kisoo
[1
,3
]
Diederich, Chris
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
Diederich, Chris
[2
]
Narsinh, Kazim
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
Narsinh, Kazim
[1
]
Ozhinsky, Eugene
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
Ozhinsky, Eugene
[1
]
机构:
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St,S341, San Francisco, CA 94115 USA
Purpose: To develop an effective and practical reconstruction pipeline to achieve motion-robust, multi-slice, real-time MR thermometry for monitoring thermal therapy in abdominal organs. Methods: The application includes a fast spiral magnetic resonance imaging (MRI) pulse sequence and a real-time reconstruction pipeline based on multi-baseline proton resonance frequency shift (PRFS) method with visualization of temperature imaging. The pipeline supports multi-slice acquisition with minimal reconstruction lag. Simulations with a virtual motion phantom were performed to investigate the influence of the number of baselines and respiratory rate on the accuracy of temperature measurement. Phantom experiments with ultrasound heating were performed using a custom-made motion phantom to evaluate the performance of the pipeline. Lastly, experiments in healthy volunteers (N= 2) without heating were performed to evaluate the accuracy and stability of MR thermometry in abdominal organs (liver and kidney). Results: The multi-baseline approach with greater than 25 baselines resulted in minimal temperature errors in the simulation. Phantom experiments demonstrated a 713ms update time for 3-slice acquisitions. Temperature maps with 30 baselines showed clear temperature distributions caused by ultrasound heating in the respiratory phantom. Finally, the pipeline was evaluated with physiologic motions in healthy volunteers without heating, which demonstrated the accuracy (root mean square error [RMSE]) of 1.23 +/- 0.18 degrees C (liver) and 1.21 7 +/- 0.17 degrees C (kidney) and precision of 1.13 +/- 0.11 degrees C (liver) and 1.16 +/- 0.15 degrees C (kidney) using 32 baselines. Conclusions: The proposed real-time acquisition and reconstruction pipeline allows motion-robust, multi-slice, real-time temperature monitoring within the abdomen during free breathing.
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USA
Kim, Kisoo
Jones, Peter
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USA
Jones, Peter
Diederich, Chris
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USA
Diederich, Chris
Ozhinsky, Eugene
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St S341, San Francisco, CA 94143 USA