Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs

被引:3
|
作者
Kim, Kisoo [1 ,3 ]
Diederich, Chris [2 ]
Narsinh, Kazim [1 ]
Ozhinsky, Eugene [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St,S341, San Francisco, CA 94115 USA
关键词
MR thermometry; abdominal organ; motion; real-time MR imaging; MR-guided thermal therapy; MAGNETIC-RESONANCE THERMOMETRY; INTENSITY FOCUSED ULTRASOUND; IN-VIVO; ABLATION; HYPERTHERMIA; REFERENCELESS; GUIDANCE;
D O I
10.1080/02656736.2022.2151649
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop an effective and practical reconstruction pipeline to achieve motion-robust, multi-slice, real-time MR thermometry for monitoring thermal therapy in abdominal organs. Methods: The application includes a fast spiral magnetic resonance imaging (MRI) pulse sequence and a real-time reconstruction pipeline based on multi-baseline proton resonance frequency shift (PRFS) method with visualization of temperature imaging. The pipeline supports multi-slice acquisition with minimal reconstruction lag. Simulations with a virtual motion phantom were performed to investigate the influence of the number of baselines and respiratory rate on the accuracy of temperature measurement. Phantom experiments with ultrasound heating were performed using a custom-made motion phantom to evaluate the performance of the pipeline. Lastly, experiments in healthy volunteers (N= 2) without heating were performed to evaluate the accuracy and stability of MR thermometry in abdominal organs (liver and kidney). Results: The multi-baseline approach with greater than 25 baselines resulted in minimal temperature errors in the simulation. Phantom experiments demonstrated a 713ms update time for 3-slice acquisitions. Temperature maps with 30 baselines showed clear temperature distributions caused by ultrasound heating in the respiratory phantom. Finally, the pipeline was evaluated with physiologic motions in healthy volunteers without heating, which demonstrated the accuracy (root mean square error [RMSE]) of 1.23 +/- 0.18 degrees C (liver) and 1.21 7 +/- 0.17 degrees C (kidney) and precision of 1.13 +/- 0.11 degrees C (liver) and 1.16 +/- 0.15 degrees C (kidney) using 32 baselines. Conclusions: The proposed real-time acquisition and reconstruction pipeline allows motion-robust, multi-slice, real-time temperature monitoring within the abdomen during free breathing.
引用
收藏
页数:13
相关论文
共 18 条
  • [1] Real-Time Method for Motion-Compensated MR Thermometry and MRgHIFU Treatment in Abdominal Organs
    Celicanin, Zarko
    Auboiroux, Vincent
    Bieri, Oliver
    Petrusca, Lorena
    Santini, Francesco
    Viallon, Magalie
    Scheffler, Klaus
    Salomir, Rares
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1087 - 1095
  • [2] Real-Time MR-Thermometry and Dosimetry for Interventional Guidance on Abdominal Organs
    Roujol, Sebastien
    Ries, Mario
    Quesson, Bruno
    Moonen, Chrit
    de Senneville, Baudouin Denis
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1080 - 1087
  • [3] MR-Guided Thermotherapy of Abdominal Organs Using a Robust PCA-Based Motion Descriptor
    de Senneville, Baudouin Denis
    Ries, Mario
    Maclair, Gregory
    Moonen, Chrit
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (11) : 1987 - 1995
  • [4] A system for advanced real-time visualization and monitoring of MR-guided thermal ablations
    Rothgang, Eva
    Gilson, Wesley D.
    Hornegger, Joachim
    Lorenz, Christine H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [5] Motion-Compensated Real-Time MR Thermometry Augmented by Tracking Coils
    Wang, Peng
    Unal, Orhan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 851 - 857
  • [6] MR-guided joint puncture and real-time MR-assisted contrast media application
    Trattnig, S
    Breitenseher, M
    Pretterklieber, M
    Kontaxis, G
    Rand, T
    Helbich, T
    Imhof, H
    ACTA RADIOLOGICA, 1997, 38 (06) : 1047 - 1049
  • [7] Real-time 3D ultrasound based motion tracking for the treatment of mobile organs with MR-guided high-intensity focused ultrasound
    Bour, Pierre
    Ozenne, Valery
    Marquet, Fabrice
    de Senneville, Baudouin Denis
    Dumont, Erik
    Quesson, Bruno
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (08) : 1225 - 1235
  • [8] Automatic Nonrigid Calibration of Image Registration for Real Time MR-Guided HIFU Ablations of Mobile Organs
    Roujol, Sebastien
    Ries, Mario
    Moonen, Chrit
    de Senneville, Baudouin Denis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (10) : 1737 - 1745
  • [9] Low-cost MR-compatible pneumatic respiratory organ motion simulator for the development of MR-guided thermal therapy
    Kim, Kisoo
    Jones, Peter
    Diederich, Chris
    Ozhinsky, Eugene
    MEDICAL PHYSICS, 2022, 49 (07) : 4365 - 4371
  • [10] Spectrally Selective Pencil-Beam Navigator for Motion Compensation of MR-Guided High-Intensity Focused Ultrasound Therapy of Abdominal Organs
    Kohler, Max O.
    de Senneville, Baudouin Denis
    Quesson, Bruno
    Moonen, Chrit T. W.
    Ries, Mario
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 102 - 111