Direct active and reactive powers control of double-powered asynchronous generators in multi-rotor wind power systems using modified synergetic control

被引:24
作者
Benbouhenni, Habib [1 ]
Bizon, Nicu [2 ,3 ]
Colak, Ilhami [1 ]
Mosaad, Mohamed I. [4 ,5 ]
Yessef, Mourad [6 ]
机构
[1] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, TR-34481742 Istanbul, Turkiye
[2] Natl Univ Sci & Technol POLITEHN Bucharest, Pitesti Univ Ctr, Pitesti 110040, Romania
[3] Natl Res & Dev Inst Cryogen & Isotop Technol, ICSI Energy, Ramnicu Valcea 240050, Romania
[4] Damietta Univ, Fac Engn, Elect Engn Dept, Dumyat 34511, Egypt
[5] Royal Commiss Yanbu Coll & Inst, Yanbu Ind Coll YIC, Elect & Elect Engn Technol Dept, Yanbu 46452, Saudi Arabia
[6] Sidi Mohammed Ben Abdellah Univ, Fes 30000, Morocco
关键词
Direct reactive and active power control; Double -powered asynchronous generators; Pulse width modulation; Modified synergetic control theory; Steady-state error; FED INDUCTION GENERATOR; VECTOR; TURBINE;
D O I
10.1016/j.egyr.2023.10.085
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the future, renewable energy sources will be of great importance in overcoming the problems of power generation using traditional sources, as their use contributes to protecting the environment from pollution and helps to raise human development. Therefore, it is necessary to search for a generation system that has high characteristics to raise the quality of energy and reduce the total cost of producing, transmitting, and consuming energy. This work proposes a new nonlinear direct reactive and active power control (DRAPC) for grid-connected double-powered asynchronous generators (DPAGs) in multi-rotor wind power (MRWP) systems. The designed DRAPC employs a modified synergetic control theory (MSCT) to regulate the DFPG-MRWP stator power. With out involving any synchronous coordinate transformations, the DRAPC-MSCT reduces the steady-state error (SSE), ripples and response time of stator powers while directly determining the required rotor control voltage. This technique fundamentally improves the transient performance compared to the DRAPC-SCT. Constant switching frequency is achieved as well by using pulse width modulation, which eases the designs of the power converters and AC harmonic filters. Through the use of three test cases (tracking test, robustness test, and variable-speed test using the Maximum Power Point Tracking), the potential of the DRAPC-MSCT to reduce system instability and uncertainty is evaluated. This comprises the ability of the controller to track DPAG powers references and improve performance during variations in system parameters and wind speed. Simulated results on a 1.5 MW grid-connected DPAG-MRWP are presented and compared with those of the DRAPC-SCT. The DRAPC-MSCT improves the reactive and active power ripples by 73.33% and 84.50%, respectively. Besides, improves the SSE of the reactive and active power by 51.61% and 69%, respectively compared to the DRAPC-SCT. The simulation results demonstrate the high performance and robustness of the DRAPC-MSCT for parametric variations of DPG-MRWP compared to the DRAPC-SCT.
引用
收藏
页码:4286 / 4301
页数:16
相关论文
共 59 条
[1]   A Characterization of Vertical Axis Wind Turbines [J].
Albuquerque, I. M. ;
Matos, F. F. S. .
IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (10) :4255-4260
[2]   Direct Power Control Optimization for Doubly Fed Induction Generator Based Wind Turbine Systems [J].
Alhato, Mohammed Mazen ;
Bouallegue, Soufiene .
MATHEMATICAL AND COMPUTATIONAL APPLICATIONS, 2019, 24 (03)
[3]  
Alzain OB, 2022, TURK J ELECTR ENG CO, V30, P659, DOI [10.3906/elk-2104-73, 10.3906/elk-2104-73, 10.55730/1300-0632.3804]
[4]  
Amrane F, 2016, REV ROUM SCI TECH-EL, V61, P319
[5]  
Amrane F, 2016, REV ROUM SCI TECH-EL, V61, P263
[6]   Direct torque control improvement of a variable speed DFIG based on a fuzzy inference system [J].
Ayrir, W. ;
Ourahou, M. ;
El Hassouni, B. ;
Haddi, A. .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2020, 167 :308-324
[7]   Multi-region dynamic economic dispatch of solar wind hydro thermal power system incorporating pumped hydro energy storage [J].
Basu, M. .
ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2019, 86 :182-196
[8]   Active and Passive Control of a Dual Rotor Wind Turbine Generator for DC Grids [J].
Beik, Omid ;
Al-Adsani, Ahmad S. .
IEEE ACCESS, 2021, 9 :1987-1995
[9]   COMBINING SYNERGETIC CONTROL AND SUPER TWISTING ALGORITHM TO REDUCE THE ACTIVE POWER UNDULATIONS OF DOUBLY FED INDUCTION GENERATOR FOR DUAL-ROTOR WIND TURBINE SYSTEM [J].
Benbouhenni, H. ;
Lemdani, S. .
ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2021, (03) :8-17
[10]  
Benbouhenni H., Int. J. Smart Grid, V3, P128