Sharp Branched Gold Nanostar-Based Lateral-Flow Immunoassay for Detection of Yersinia pestis

被引:17
作者
Atta, Supriya [1 ,2 ]
Canning, Aidan J. [1 ]
Odion, Ren [1 ]
Wang, Hsin-neng [1 ]
Hau, Derrick [2 ]
Devadhasan, Jasmine Pramila [3 ]
Summers, Alexander Jarrett [3 ]
Gates-Hollingsworth, Marcellene A. [2 ]
Pflughoeft, Kathryn J. [2 ]
Gu, Jian [3 ,4 ]
Montgomery, Douglas C. [3 ,5 ]
AuCoin, David P. [2 ]
Zenhausern, Frederic [3 ,4 ]
Vo-Dinh, Tuan [1 ]
机构
[1] Duke Univ, Fitzpatrick Inst Photon, Durham, NC 27708 USA
[2] Duke Univ, Dept Biomed Engn, Dept Chem, Durham, NC 27708 USA
[3] Univ Nevada, Reno Sch Med, Dept Microbiol & Immunol, Reno, NV 89557 USA
[4] Univ Arizona, Coll Med, Ctr Appl NanoBiosci & Med, Phoenix, AZ 85004 USA
[5] Univ Arizona, Coll Med, Dept Basic Med Sci, Phoenix, AZ 85004 USA
关键词
gold nanostars; gold nanospheres; LFIA; Yersinia pestis; lateral flow; sharp branches; PERFORMANCE; NANOPARTICLES; ASSAY;
D O I
10.1021/acsanm.2c05557
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Over the past few decades, colorimetric paper-based lateral flow immunoassay (LFIA) has emerged as a versatile analytical tool for rapid point-of-care detection of infectious diseases with high simplicity and flexibility. The LFIA sensitivity is based on color visualization of the antibody-labeled nanoparticles bound with the target analytes at the test line. Therefore, the nanoparticle design is crucial for LFIA sensitivity. The traditional LFIA is based on spherical gold nanoparticles, which usually suffer from poor sensitivity because of very low optical contrast at the test line. To improve the LFIA sensitivity, we have developed an LFIA based on gold nanostars (GNSs) with different branch lengths and sharpness (GNS-1, GNS-2, and GNS-3), which possess higher optical contrast than conventional gold nanospheres (GNSPs). We have selected the bacterium Yersinia pestis as a model analyte system. The effective affinity of GNSPs and GNSs with the Y. pestis fraction 1 (F1) protein was quantitively investigated by colorimetric and optical density measurements of the test line. The results show that GNS-3, which has maximum spike length and branch sharpness, exhibits the highest analytical sensitivity based on the limit of detection of the LFIA readout compared to other GNSs and GNSPs. The detection limit of the Y. pestis F1 antigen was achieved up to 0.1 ng/mL for GNS-3, which is 100 times lower than that for the GNSP at a 1 pmol/L concentration and 10 times lower than that for the reported procedure based on traditional gold nanoparticles. Overall, our prototype LFIA platform based on a highly spiked GNS (GNS-3) exhibits high analytical sensitivity, indicating it to be a promising candidate for routine LFIA application to detect infectious diseases.
引用
收藏
页码:3884 / 3892
页数:9
相关论文
共 51 条
[1]   Gold Nanoparticle-Mediated Lateral Flow Assays for Detection of Host Antibodies and COVID-19 Proteins [J].
Ardekani, Leila Safaee ;
Thulstrup, Peter Waaben .
NANOMATERIALS, 2022, 12 (09)
[2]   Bimetallic Gold Nanostars Having High Aspect Ratio Spikes for Sensitive Surface-Enhanced Raman Scattering Sensing [J].
Atta, Supriya ;
Vo-Dinh, Tuan .
ACS APPLIED NANO MATERIALS, 2022, 5 (09) :12562-12570
[3]   Ultra-high SERS detection of consumable coloring agents using plasmonic gold nanostars with high aspect-ratio spikes [J].
Atta, Supriya ;
Watcharawittayakul, Tongchatra ;
Vo-Dinh, Tuan .
ANALYST, 2022, 147 (14) :3340-3349
[4]   Understanding the role of AgNO3 concentration and seed morphology in the achievement of tunable shape control in gold nanostars [J].
Atta, Supriya ;
Beetz, Michael ;
Fabris, Laura .
NANOSCALE, 2019, 11 (06) :2946-2958
[5]   Shaping Gold Nanostar Electric Fields for Surface-Enhanced Raman Spectroscopy Enhancement via Silica Coating and Selective Etching [J].
Atta, Supriya ;
Tsoulos, Ted V. ;
Fabris, Laura .
JOURNAL OF PHYSICAL CHEMISTRY C, 2016, 120 (37) :20749-20758
[6]   Gold-sulfur bonding in 2D and 3D self-assembled monolayers: XPS characterization [J].
Bourg, MC ;
Badia, A ;
Lennox, RB .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (28) :6562-6567
[7]   Less is More: A Comparison of Antibody-Gold Nanoparticle Conjugates of Different Ratios [J].
Byzova, Nadezhda A. ;
Safenkova, Irina V. ;
Slutskaya, Elvira S. ;
Zherdev, Anatoly V. ;
Dzantiev, Boris B. .
BIOCONJUGATE CHEMISTRY, 2017, 28 (11) :2737-2746
[8]   Development and testing of a rapid diagnostic test for bubonic and pneumonic plague [J].
Chanteau, S ;
Rahalison, L ;
Ralafiarisoa, L ;
Foulon, J ;
Ratsitorahina, M ;
Ratsifasoamanana, L ;
Carniel, E ;
Nato, A .
LANCET, 2003, 361 (9353) :211-216
[9]   Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives [J].
Di Nardo, Fabio ;
Chiarello, Matteo ;
Cavalera, Simone ;
Baggiani, Claudio ;
Anfossi, Laura .
SENSORS, 2021, 21 (15)
[10]   Some interesting properties of metals confined in time and nanometer space of different shapes [J].
El-Sayed, MA .