One-year follow-up comparison of two hybrid closed-loop systems in Italian children and adults with type 1 diabetes

被引:18
作者
Bassi, Marta [1 ,2 ]
Patti, Luca [3 ]
Silvestrini, Irene [3 ]
Strati, Marina Francesca [1 ,2 ]
Ponzano, Marta [4 ]
Minuto, Nicola [2 ]
Maggi, Davide [3 ,5 ]
机构
[1] Univ Genoa, Dept Neurosci Rehabil Ophthalmol Genet Maternal &, Genoa, Italy
[2] Univ Genoa, IRCCS Ist Giannina Gaslini, Dept Pediat, Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties DiMI, Genoa, Italy
[4] Univ Genoa, Dept Hlth Sci DiSSAL, Genoa, Italy
[5] IRCCS Osped Policlin San Martino Genoa, Diabet Clin, Genoa, Italy
来源
FRONTIERS IN ENDOCRINOLOGY | 2023年 / 14卷
关键词
AHCL (Advanced Hybrid Closed Loop); type; 1; diabetes; CGM; continous glucose monitoring; TIR (time in range); CSII; continuous subcutaneous insulin infusion;
D O I
10.3389/fendo.2023.1099024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aimsTandem Control-IQ and MiniMed 780G are the main Advanced Hybrid Closed Loop (AHCL) systems currently available in pediatric and adult patients with Type 1 Diabetes (T1D). The aim of our study was to evaluate glycemic control after 1-year of follow-up extending our previous study of 1-month comparison between the two systems. MethodsWe retrospectively compared clinical and continuous glucose monitoring (CGM) data from the patients included in the previous study which have completed 1-year observation period. The study population consisted of 74 patients, 42 Minimed 780G users and 32 Tandem Control-IQ users. Linear mixed models with random intercept were performed to study the variations over time and the interaction between time and system; Mann-Whitney or T-test were used to compare systems at 1-year. ResultsBoth systems have been shown to be effective in maintaining the glycemic improvement achieved one month after starting AHCL. Significant changes over time were observed for TIR, TAR, TAR>250mg/dl, average glucose levels and SD (p<0.001). At 1-year follow-up Minimed 780G obtained better improvement in TIR (p<0.001), TAR (p=0.002), TAR>250mg/dl (p=0.001), average glucose levels (p<0.001). The comparison of the glycemic parameters at 1-year showed a significant superiority of Minimed 780G in terms of TIR (71% vs 68%; p=0.001), TAR (p=0.001), TAR>250 (p=0.009), average glucose levels(p=0.001) and SD (p=0.031). ConclusionsThe use of AHCL systems led to a significant improvement of glycemic control at 1-month, which is maintained at 1-year follow-up. MiniMed is more effective than Tandem in reaching the International recommended glycemic targets. Continuous training and education in the use of technology is essential to get the best out of the most advanced technological tools.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The Use of a Hybrid Closed-Loop System for Glycemic Control in Two Pediatric Patients with Type 1 Diabetes Undergoing Minor Surgery
    Seget, Sebastian
    Wlodarczyk, Julia
    Lutogniewska, Wanda
    Rusak, Ewa
    Drozdz, Maria
    Jarosz-Chobot, Przemyslawa
    HEALTHCARE, 2023, 11 (04)
  • [42] Closed-Loop Insulin Therapy in Older Adults with Type 1 Diabetes: Real-World Data
    Toschi, Elena
    Atakov-Castillo, Astrid
    Slyne, Christine
    Munshi, Medha
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (02) : 140 - 142
  • [43] Glucose Control in Adults with Type 1 Diabetes Using a Medtronic Prototype Enhanced-Hybrid Closed-Loop System: A Feasibility Study
    Lee, Melissa H.
    Vogrin, Sara
    Paldus, Barbora
    Jones, Hannah M.
    Obeyesekere, Varuni
    Sims, Catriona
    Wyatt, Sue-Anne
    Ward, Glenn M.
    McAuley, Sybil A.
    MacIsaac, Richard J.
    Krishnamurthy, Balasubramanian
    Sundararajan, Vijaya
    Jenkins, Alicia J.
    O'Neal, David N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (09) : 499 - 506
  • [44] Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes
    Carlson, Anders L.
    Sherr, Jennifer L.
    Shulman, Dorothy, I
    Garg, Satish K.
    Pop-Busui, Rodica
    Bode, Bruce W.
    Lilenquist, David R.
    Brazg, Ron L.
    Kaiserman, Kevin B.
    Kipnes, Mark S.
    Thrasher, James R.
    Reed, John H. Chip
    Slover, Robert H.
    Philis-Tsimikas, Athena
    Christiansen, Mark
    Grosman, Benyamin
    Roy, Anirban
    Vella, Melissa
    Jonkers, Richard A. M.
    Chen, Xiaoxiao
    Shin, John
    Cordero, Toni L.
    Lee, Scott W.
    Rhinehart, Andrew S.
    Vigersky, Robert A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (03) : 178 - 189
  • [45] Impact of the Hybrid Closed-Loop System on Sleep and Quality of Life in Youth with Type 1 Diabetes and Their Parents
    Cobry, Erin C.
    Hamburger, Emily
    Jaser, Sarah S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 794 - 800
  • [46] Hypoglycemia and Hyperglycemia According to Type of Diabetes: Observations During Fully Closed-Loop Insulin Delivery in Adults With Type 1 and Type 2 Diabetes
    Kadiyala, Nithya
    Wilinska, Malgorzata E.
    Daly, Aideen B.
    Nwokolo, Munachiso
    Lakshman, Rama
    Hartnell, Sara
    Ware, Julia
    Allen, Janet M.
    Cezar, Alina
    Evans, Mark L.
    Hovorka, Roman
    Boughton, Charlotte K.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [47] Clinical Outcomes with MiniMed™ 780G Advanced Hybrid Closed-Loop Therapy in 2-to 6-Year-Old Children with Type 1 Diabetes
    Abraham, Mary B.
    Smith, Grant J.
    Dart, Julie
    Davis, Elizabeth A.
    Jones, Timothy W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (05) : 341 - 345
  • [48] Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Children and Adolescents with Type 1 Diabetes
    Pihoker, Catherine
    Shulman, Dorothy I.
    Forlenza, Gregory P.
    Kaiserman, Kevin B.
    Sherr, Jennifer L.
    Thrasher, James R.
    Buckingham, Bruce A.
    Kipnes, Mark S.
    Bode, Bruce W.
    Carlson, Anders L.
    Lee, Scott W.
    Latif, Kashif
    Liljenquist, David R.
    Slover, Robert H.
    Dai, Zheng
    Niu, Fang
    Shin, John
    Jonkers, Richard A. M.
    Roy, Anirban
    Grosman, Benyamin
    Vella, Melissa
    Cordero, Toni L.
    Mcvean, Jennifer
    Rhinehart, Andrew S.
    Vigersky, Robert A.
    MiniMedTM AHCL Study Grp
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (11) : 755 - 764
  • [49] A Comparison of Glucose and Additional Signals for Three Different Exercise Types in Adolescents with Type 1 Diabetes Using a Hybrid Closed-Loop System
    Seckold, Rowen
    Smart, Carmel E.
    O'Neal, David N.
    Riddell, Michael C.
    Rafferty, Jordan
    Morrison, Dale
    Obeyesekere, Varuni
    Gooley, Judy L.
    Paldus, Barbora
    Valkenborghs, Sarah R.
    Vogrin, Sara
    Zaharieva, Dessi P.
    King, Bruce R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2025,
  • [50] The challenges of achieving postprandial glucose control using closed-loop systems in patients with type 1 diabetes
    Gingras, Veronique
    Taleb, Nadine
    Roy-Fleming, Amelie
    Legault, Laurent
    Rabasa-Lhoret, Remi
    DIABETES OBESITY & METABOLISM, 2018, 20 (02) : 245 - 256