One-year follow-up comparison of two hybrid closed-loop systems in Italian children and adults with type 1 diabetes

被引:21
作者
Bassi, Marta [1 ,2 ]
Patti, Luca [3 ]
Silvestrini, Irene [3 ]
Strati, Marina Francesca [1 ,2 ]
Ponzano, Marta [4 ]
Minuto, Nicola [2 ]
Maggi, Davide [3 ,5 ]
机构
[1] Univ Genoa, Dept Neurosci Rehabil Ophthalmol Genet Maternal &, Genoa, Italy
[2] Univ Genoa, IRCCS Ist Giannina Gaslini, Dept Pediat, Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties DiMI, Genoa, Italy
[4] Univ Genoa, Dept Hlth Sci DiSSAL, Genoa, Italy
[5] IRCCS Osped Policlin San Martino Genoa, Diabet Clin, Genoa, Italy
来源
FRONTIERS IN ENDOCRINOLOGY | 2023年 / 14卷
关键词
AHCL (Advanced Hybrid Closed Loop); type; 1; diabetes; CGM; continous glucose monitoring; TIR (time in range); CSII; continuous subcutaneous insulin infusion;
D O I
10.3389/fendo.2023.1099024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aimsTandem Control-IQ and MiniMed 780G are the main Advanced Hybrid Closed Loop (AHCL) systems currently available in pediatric and adult patients with Type 1 Diabetes (T1D). The aim of our study was to evaluate glycemic control after 1-year of follow-up extending our previous study of 1-month comparison between the two systems. MethodsWe retrospectively compared clinical and continuous glucose monitoring (CGM) data from the patients included in the previous study which have completed 1-year observation period. The study population consisted of 74 patients, 42 Minimed 780G users and 32 Tandem Control-IQ users. Linear mixed models with random intercept were performed to study the variations over time and the interaction between time and system; Mann-Whitney or T-test were used to compare systems at 1-year. ResultsBoth systems have been shown to be effective in maintaining the glycemic improvement achieved one month after starting AHCL. Significant changes over time were observed for TIR, TAR, TAR>250mg/dl, average glucose levels and SD (p<0.001). At 1-year follow-up Minimed 780G obtained better improvement in TIR (p<0.001), TAR (p=0.002), TAR>250mg/dl (p=0.001), average glucose levels (p<0.001). The comparison of the glycemic parameters at 1-year showed a significant superiority of Minimed 780G in terms of TIR (71% vs 68%; p=0.001), TAR (p=0.001), TAR>250 (p=0.009), average glucose levels(p=0.001) and SD (p=0.031). ConclusionsThe use of AHCL systems led to a significant improvement of glycemic control at 1-month, which is maintained at 1-year follow-up. MiniMed is more effective than Tandem in reaching the International recommended glycemic targets. Continuous training and education in the use of technology is essential to get the best out of the most advanced technological tools.
引用
收藏
页数:7
相关论文
共 31 条
[1]   Efficacy and Safety of Tandem Control IQ Without User-Initiated Boluses in Adults with Uncontrolled Type 1 Diabetes [J].
Akturk, Halis Kaan ;
Snell-Bergeon, Janet ;
Shah, Viral N. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (10) :779-783
[2]  
[Anonymous], 2020, COMMISSIONER O FDA A
[3]   Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: Evidence from 12 870 real-world users [J].
Arrieta, Arcelia ;
Battelino, Tadej ;
Scaramuzza, Andrea E. ;
Da Silva, Julien ;
Castaneda, Javier ;
Cordero, Toni L. ;
Shin, John ;
Cohen, Ohad .
DIABETES OBESITY & METABOLISM, 2022, 24 (07) :1370-1379
[4]   A Comparison of Two Hybrid Closed-Loop Systems in Italian Children and Adults With Type 1 Diabetes [J].
Bassi, Marta ;
Teliti, Marsida ;
Lezzi, Marilea ;
Iosca, Arianna ;
Strati, Marina Francesca ;
Carmisciano, Luca ;
d'Annunzio, Giuseppe ;
Minuto, Nicola ;
Maggi, Davide .
FRONTIERS IN ENDOCRINOLOGY, 2022, 12
[5]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[6]   Rapid Improvement in Time in Range After the Implementation of an Advanced Hybrid Closed-Loop System in Adolescents and Adults with Type 1 Diabetes [J].
Beato-Vibora, Pilar Isabel ;
Gallego-Gamero, Fabiola ;
Ambrojo-Lopez, Ana ;
Gil-Poch, Estela ;
Martin-Romo, Irene ;
Arroyo-Diez, Francisco Javier .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (09) :609-615
[7]  
Bergenstal RM, 2021, LANCET, V397, P208, DOI 10.1016/S0140-6736(20)32514-9
[8]   Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Garg, Satish ;
Weinzimer, Stuart A. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Tamborlane, William V. ;
Kaufman, Francine R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13) :1407-1408
[9]   New closed-loop insulin systems [J].
Boughton, Charlotte K. ;
Hovorka, Roman .
DIABETOLOGIA, 2021, 64 (05) :1007-1015
[10]   One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology [J].
Breton, Marc D. ;
Kovatchev, Boris P. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (09) :601-608