Improvement of the PEA system with High Spatial Resolution at High-Temperature Measurement

被引:0
|
作者
Kobayashi, Ryota [1 ]
Sato, Kosuke [1 ]
Miyake, Hiroaki [1 ]
Tanaka, Yasuhiro [1 ]
机构
[1] Tokyo City Univ, Tokyo, Japan
关键词
D O I
10.1109/CEIDPS51414.2023.10410572
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Abstrtlct- Partial disdlarge (PD) associated with higher voltages in inverter-driven moton has become a problem; one of the reduction eauses of PD-ineeption voltage is said to be the spaee &:barge that aecumulates in the winding eoating material, especially at high temperatures, and it is neeessary to investigate this aeeumnlation ebaraeteristie. However, the typieal thickness of the eoating material of the windings used in electrie vehides is about 30 p.m, maldng it dUDeult to measure the spaec charge distribution with the usual PEA (pulse electrostatie stress) method, wbieh has a spatial resolution of about 10 pm. In the present study, a thin P(VDF-TrFE) piezoelectric sensor was formed directly onto a ground eledrode deposited on both sides of sapphire glass, whieh is said to have good acoustie propagation Characteristics, by the spin eoating method, and used to obtain a po1ition resolution of about 2.5 11m at 80 degrees C. The resolution was sueeessfully improved signifieandy.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Improvement of the image quality of a high-temperature vision system
    Fabijanska, Anna
    Sankowski, Dominik
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
  • [12] Photothermic microscopy - Noncontactless temperature measurement with high spatial resolution
    Hartmann, J
    Reichling, M
    TEMPERATURE '98, 1998, 1379 : 221 - 226
  • [13] HIGH-TEMPERATURE HIGH-RESOLUTION METALLOGRAPHY
    ANSELL, GS
    AARONSON, HI
    JOURNAL OF METALS, 1965, 17 (06): : 622 - &
  • [14] A high-temperature superconducting Maglev dynamic measurement system
    Wang, Jiasu
    Wang, Suyu
    Deng, Changyan
    Zeng, Youwen
    Zhang, Longcai
    Deng, Zigang
    Zheng, Jun
    Liu, Lu
    Lu, Yiyun
    Liu, Minxian
    Lu, Yaohui
    Huang, Yonggang
    Zhang, Ya
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 791 - 794
  • [15] HIGH-TEMPERATURE MEASUREMENT SYSTEM DEVISED FOR CLAUS REACTORS
    WADI, I
    OIL & GAS JOURNAL, 1989, 87 (47) : 60 - &
  • [16] VOID FRACTION MEASUREMENT SYSTEM FOR HIGH-TEMPERATURE FLOWS
    TEYSSEDOU, A
    AUBE, F
    CHAMPAGNE, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (05) : 485 - 494
  • [17] A temperature measurement system with high resolution and low noise
    Zhang, Bing
    Zhu, Xiaoyi
    Zhang, Xiaofeng
    Xue, Bing
    Liang, Hong
    Li, Jiang
    Su, Peng
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2021, 36 (11-12):
  • [18] The design of the dynamic surface high-temperature measurement system
    Hao, XJ
    Zhou, HC
    Hao, LN
    Zhaoyu
    Wanggao
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 3161 - 3164
  • [19] An update high-temperature superconducting maglev measurement system
    Wang, Suyu
    Wang, Jiasu
    Deng, Changyan
    Lu, Yiyu
    Zeng, Youwen
    Song, Honghai
    Huang, Haiyu
    Jing, Hua
    Huang, Yonggang
    Zheng, Jun
    Wang, Xingzhi
    Zhang, Ya
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2067 - 2070
  • [20] AN ELECTROCHEMICAL MEASUREMENT OF HIGH-TEMPERATURE DIFFUSION IN A METAL SYSTEM
    RALEIGH, DO
    CROWE, HR
    JOURNAL OF METALS, 1968, 20 (08): : A76 - &