Electrochemical determination of metformin via a carbon paste electrode modified with an Ag NPs/Cu2O/CuO-decorated bacterial nanocellulose composite

被引:4
作者
Zamani, S. [1 ]
Ghanbari, Kh. [1 ]
Bonyadi, S. [1 ]
机构
[1] Alzahra Univ, Fac Chem, Dept Analyt Chem, POB 1993893973, Tehran, Iran
关键词
REDUCED GRAPHENE OXIDE; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION; NANOPARTICLES; SENSOR; HYDROCHLORIDE; NANOCOMPOSITE; FABRICATION; URINE;
D O I
10.1039/d3ay00703k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metformin (MET) is widely used in the treatment of diabetes either alone or in combination with other drugs, in drug discovery to evaluate the anti-diabetic potential of other drugs, and usually as a comparison compound in pharmacokinetics/pharmacodynamics studies. Measuring the concentration of this substance is very important both pre-clinically in different species and clinically in the medical monitoring of diabetic patients to prevent toxicity and ensure adherence to described drugs. Therefore, it is very important to develop a sensitive and selective method to measure MET. In this work, a new electrochemical biosensor based on a carbon paste electrode, modified with bacterial nanocellulose, copper oxide, and silver nanoparticles (Ag NPs/Cu2O/CuO/BNC/CPE) was used for high-sensitivity MET determination. The morphology and structure of this bio-nanocomposite were characterized by ATR-IR, FE-SEM, EDS, mapping, XRD, and DRS techniques. Compared with the CPE electrode, the Ag NPs/Cu2O/ CuO/BNC/CPE modified electrode showed much higher electrocatalytic activities toward the oxidation of MET. The measurements were carried out by the cyclic voltammetry technique. Surface conductance was evaluated using the impedance technique. The results showed an increase in surface conductivity. The detection limit was obtained at 42.3 nM and two linear ranges 0.1-76 and 76-1000.0 mu M were observed. The developed sensor had good features such as high sensitivity, reproducibility and repeatability, low detection limit, and fast response time. The obtained results from the real sample (MET tablets) were completely satisfactory.
引用
收藏
页码:4606 / 4614
页数:9
相关论文
共 38 条
  • [21] Production of copper-graphene nanocomposite as a voltammetric sensor for determination of anti-diabetic metformin using response surface methodology
    Hassasi, Shima
    Hassaninejad-Darzi, Seyed Karim
    Vahid, Amir
    [J]. MICROCHEMICAL JOURNAL, 2022, 172
  • [22] Validated Liquid Chromatographic Method for the Determination of (Canagliflozin, Dapagliflozin or Empagliflozin) and Metformin in the Presence of (1-Cyanoguanidine)
    Hassib, Sonia T.
    Taha, Elham A.
    Elkady, Ehab F.
    Barakat, Ghada H.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (08) : 697 - 707
  • [23] Au-SH-SiO2 nanoparticles supported on metal-organic framework (Au-SH-SiO2@Cu-MOF) as a sensor for electrocatalytic oxidation and determination of hydrazine
    Hosseini, Hadi
    Ahmar, Hamid
    Dehghani, Ali
    Bagheri, Akbar
    Fakhari, Ali Reza
    Amini, Mostafa M.
    [J]. ELECTROCHIMICA ACTA, 2013, 88 : 301 - 309
  • [24] Nanocellulose-based sensors in medical/clinical applications: The state-of-the-art review
    Langari, Mahsa Mousavi
    Nikzad, Maryam
    Labidi, Jalel
    [J]. CARBOHYDRATE POLYMERS, 2023, 304
  • [25] Nuclear magnetic resonance spectroscopy-based urinalysis for a young girl with extreme hypoglycaemia
    Law, Chun-yiu
    Kwok, Anne Mei-kwun
    Ling, Tsz-ki
    Wong, Ka-chung
    Lau, Nike Kwai-cheung
    Poon, Grace Wing-kit
    Lam, Ching-wan
    [J]. PATHOLOGY, 2022, 54 (04) : 505 - 508
  • [26] Antidiabetic Drug Metformin Oxidation and in situ Interaction with dsDNA Using a dsDNA-electrochemical Biosensor
    Machini, W. B. S.
    Fernandes, I. P. G.
    Oliveira-Brett, A. M.
    [J]. ELECTROANALYSIS, 2019, 31 (10) : 1977 - 1987
  • [27] Preparation of γ-Fe2O3/hydroxyapatite/Cu(II) magnetic nanocomposite and its application for electrochemical detection of metformin in urine and pharmaceutical samples
    Mirzajani, Roya
    Karimi, Somayeh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 270 : 405 - 416
  • [28] Copper hydroxide nanostructure-modified carbon ionic liquid electrode as an efficient voltammetric sensor for detection of metformin: a theoretical and experimental study
    Momeni, S.
    Farrokhnia, M.
    Karimi, S.
    Nabipour, I.
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2016, 13 (06) : 1027 - 1035
  • [29] A validated LC-MS/MS method for simultaneous determination of linagliptin and metformin in spiked human plasma coupled with solid phase extraction: Application to a pharmacokinetic study in healthy volunteers
    Moussa, Bahia Abbas
    Mahrouse, Marianne Alphonse
    Fawzy, Michael Gamal
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 163 : 153 - 161
  • [30] Silver nanoparticle/bacterial nanocellulose paper composites for paste-and-read SERS detection of pesticides on fruit surfaces
    Parnsubsakul, Attasith
    Ngoensawat, Umphan
    Wutikhun, Tuksadon
    Sukmanee, Thanyada
    Sapcharoenkun, Chaweewan
    Pienpinijtham, Prompong
    Ekgasit, Sanong
    [J]. CARBOHYDRATE POLYMERS, 2020, 235 (235)