Investigation on feasible zone of nozzle spray for pre-cooling the inlet air of natural draft dry cooling tower

被引:11
作者
Pang, Huimin [1 ]
Zhao, Chunrong [2 ]
Cheng, Shen [3 ]
Wang, Mingwei [4 ]
Gao, Qi [1 ,4 ]
He, Suoying [1 ]
Sun, Gengsheng [5 ]
Jiang, Guangxu [5 ]
Sun, Qinggang [5 ]
Liu, Zhilan [6 ]
Geng, Zhe [7 ]
Zhang, Shuzhen [7 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High efficiency Energy Conservat, Jinan 250061, Shandong, Peoples R China
[2] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4072, Australia
[3] Qilu Univ Technol, Sch Energy & Power Engn, Jinan 250353, Shandong, Peoples R China
[4] Shandong Casen Heat Transfer Technol Co Ltd, Weifang 261055, Shandong, Peoples R China
[5] Zhaolou Power Plant Shandong Huaju Energy Co LTD, Heze 274700, Shandong, Peoples R China
[6] Himile Mech Sci & Technol Shandong Co Ltd, Weifang 261550, Shandong, Peoples R China
[7] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
关键词
Natural draft dry cooling tower; Nozzle spray; Arrangement; Evaporation; Numerical simulation; WATER SPRAY; NUMERICAL-SIMULATION; PERFORMANCE; SYSTEM; MEDIA; FLOW; ARRANGEMENT; SHRINKAGE;
D O I
10.1016/j.tsep.2023.101650
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nozzle spray pre-cooling the inlet air can improve the thermal performance of natural draft dry cooling towers (NDDCTs). Nozzle arrangement is of great importance for achieving good performance improvement with minor water consumption. To this end, a 3-D model of spray pre-cooled NDDCT was established using FLUENT 16.2, aiming to investigate the feasible zone of spray pre-cooling of the NDDCT with three nozzles based on the behavior of the spray water droplets. Twelve nozzle heights, twelve nozzle radiuses and three spray angles are simulated for a 120 m-high NDDCT application. The evaporation percentage higher than 99.0 % is the nozzle's feasible position where the droplets can be almost completely evaporated. Simulation finds that: (1) the nozzle arrangement height should be set at 3 - 13 m. The evaporation percentage of droplets is less than 99.0 % at a height of 2 m and thus this height is not recommended. (2) The feasible arrangement radiuses of nozzles are different with their heights. The feasible arrangement radiuses of nozzles at the heights of 3 m, 4 - 5 m, 6 m, 7 8 m and 9 - 13 m are 35 - 44 m, 30 - 44 m, 35 - 44 m, 40 - 45 m and 45 - 50 m, respectively. (3) Spray angles of 90 degrees are suitable in the low-height zone with the radiuses of 30 - 44 m. Spray angles of 0 degrees, 45 degrees, or 90 degrees with a radius of 45 m are suitable for the middle-height zone. Spray angles of 0 degrees, 45 degrees, or 90 degrees with a radius of 50 m are suitable in the high-height zone.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A new natural draft dry cooling tower with improved thermal performance during windy condition
    Goodarzi, M.
    Maryamnegari, S. Moradi
    APPLIED THERMAL ENGINEERING, 2018, 139 : 341 - 351
  • [42] Numerical study of the dynamic response of the natural draft dry cooling tower under crosswind condition
    Zhang, Liang
    Li, Xiaoxiao
    Zhou, Jinxiao
    Yu, Yuanyuan
    Feng, Junjie
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [43] A Proposed Heterogeneous Distribution of Water for Natural Draft Dry Cooling Tower to Improve Cooling Efficiency under Crosswind
    Goodarzi, Mohsen
    Amooie, Hossein
    2012 4TH CONFERENCE ON THERMAL POWER PLANTS (CTPP), 2012,
  • [44] Optimization design of solar enhanced natural draft dry cooling tower
    Zou, Zheng
    Guan, Zhiqiang
    Gurgenci, Hal
    ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 945 - 955
  • [45] Numerical simulation of solar enhanced natural draft dry cooling tower
    Zou, Zheng
    Guan, Zhiqiang
    Gurgenci, Hal
    SOLAR ENERGY, 2014, 101 : 8 - 18
  • [46] Ventilation enhancement for a natural draft dry cooling tower in crosswind via windbox installation
    Wang, Weiliang
    Zhang, Hai
    Lyu, Junfu
    Liu, Qing
    Yue, Guangxi
    Ni, Weidou
    APPLIED THERMAL ENGINEERING, 2018, 137 : 93 - 100
  • [47] A quantitative approach identifies the critical flow characteristics in a natural draft dry cooling tower
    Wang, Weiliang
    Lv, Junfu
    Zhang, Hai
    Liu, Qing
    Yue, Guangxi
    Ni, Weidou
    APPLIED THERMAL ENGINEERING, 2018, 131 : 522 - 530
  • [48] Numerical investigation on novel water distribution for natural draft wet cooling tower
    Zhou, Xiaohui
    Wang, Weijia
    Chen, Lei
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181
  • [49] Numerical simulation of flow and heat transfer characteristics in Solar Enhanced Natural Draft Dry Cooling Tower
    Yuan, Lijun
    Zhu, Jialing
    Li, Tailu
    Fan, Haolong
    Lu, Xinli
    APPLIED THERMAL ENGINEERING, 2015, 87 : 98 - 105
  • [50] Three-Dimensional Regularities of Distribution of Air-Inlet Characteristic Velocity in Natural-Draft wet Cooling Tower
    Kai Wang
    Feng-zhong Sun
    Yuan-bin Zhao
    Ming Gao
    Yue-tao Shi
    Journal of Hydrodynamics, 2008, 20 : 323 - 330