Investigation on feasible zone of nozzle spray for pre-cooling the inlet air of natural draft dry cooling tower

被引:11
|
作者
Pang, Huimin [1 ]
Zhao, Chunrong [2 ]
Cheng, Shen [3 ]
Wang, Mingwei [4 ]
Gao, Qi [1 ,4 ]
He, Suoying [1 ]
Sun, Gengsheng [5 ]
Jiang, Guangxu [5 ]
Sun, Qinggang [5 ]
Liu, Zhilan [6 ]
Geng, Zhe [7 ]
Zhang, Shuzhen [7 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High efficiency Energy Conservat, Jinan 250061, Shandong, Peoples R China
[2] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4072, Australia
[3] Qilu Univ Technol, Sch Energy & Power Engn, Jinan 250353, Shandong, Peoples R China
[4] Shandong Casen Heat Transfer Technol Co Ltd, Weifang 261055, Shandong, Peoples R China
[5] Zhaolou Power Plant Shandong Huaju Energy Co LTD, Heze 274700, Shandong, Peoples R China
[6] Himile Mech Sci & Technol Shandong Co Ltd, Weifang 261550, Shandong, Peoples R China
[7] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
关键词
Natural draft dry cooling tower; Nozzle spray; Arrangement; Evaporation; Numerical simulation; WATER SPRAY; NUMERICAL-SIMULATION; PERFORMANCE; SYSTEM; MEDIA; FLOW; ARRANGEMENT; SHRINKAGE;
D O I
10.1016/j.tsep.2023.101650
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nozzle spray pre-cooling the inlet air can improve the thermal performance of natural draft dry cooling towers (NDDCTs). Nozzle arrangement is of great importance for achieving good performance improvement with minor water consumption. To this end, a 3-D model of spray pre-cooled NDDCT was established using FLUENT 16.2, aiming to investigate the feasible zone of spray pre-cooling of the NDDCT with three nozzles based on the behavior of the spray water droplets. Twelve nozzle heights, twelve nozzle radiuses and three spray angles are simulated for a 120 m-high NDDCT application. The evaporation percentage higher than 99.0 % is the nozzle's feasible position where the droplets can be almost completely evaporated. Simulation finds that: (1) the nozzle arrangement height should be set at 3 - 13 m. The evaporation percentage of droplets is less than 99.0 % at a height of 2 m and thus this height is not recommended. (2) The feasible arrangement radiuses of nozzles are different with their heights. The feasible arrangement radiuses of nozzles at the heights of 3 m, 4 - 5 m, 6 m, 7 8 m and 9 - 13 m are 35 - 44 m, 30 - 44 m, 35 - 44 m, 40 - 45 m and 45 - 50 m, respectively. (3) Spray angles of 90 degrees are suitable in the low-height zone with the radiuses of 30 - 44 m. Spray angles of 0 degrees, 45 degrees, or 90 degrees with a radius of 45 m are suitable for the middle-height zone. Spray angles of 0 degrees, 45 degrees, or 90 degrees with a radius of 50 m are suitable in the high-height zone.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Investigation on the control mechanism of spray pre-cooling the inlet air of natural draft dry cooling tower
    He, Suoying
    Li, Yang
    Wang, Mingwei
    Wang, Aiping
    Alkhedhair, Abdullah M.
    Guan, Hongjun
    Wu, Xuehong
    Shi, Yuetao
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [2] Investigation on the spray strategy for the inlet air pre-cooling of natural draft dry cooling tower under typical crosswind
    Liu, Tiantian
    Wang, Jucheng
    Song, Tianyi
    He, Suoying
    Zhan, Jianwei
    Geng, Zhe
    Zhang, Shuzhen
    Huang, Xiang
    Qi, Jianhui
    Gao, Ming
    Shi, Yuetao
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2023, 239
  • [3] Nozzle arrangement study for pre-cooling the inlet air of natural draft dry cooling tower under crosswinds
    Pang, Huimin
    Wang, Mingwei
    Gao, Qi
    Cheng, Shen
    Liu, Zhilan
    Geng, Zhe
    Zhang, Shuzhen
    He, Suoying
    Liu, Tiantian
    Zhao, Cuilin
    Liu, Wangrui
    Gao, Ming
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 1 - 12
  • [4] Numerical simulation of water spray for pre-cooling of inlet air in natural draft dry cooling towers
    Alkhedhair, Abdullah
    Gurgenci, Hal
    Jahn, Ingo
    Guan, Zhiqiang
    He, Suoying
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 416 - 424
  • [5] Water spray for pre-cooling of inlet air for Natural Draft Dry Cooling Towers - Experimental study
    Alkhedhair, Abdullah
    Guan, Zhiqiang
    Jahn, Ingo
    Gurgenci, Hal
    He, Suoying
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 90 : 70 - 78
  • [6] Investigations on the influence of nozzle arrangement on the pre-cooling effect for the natural draft dry cooling tower
    Sun, Yubiao
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    Li, Xiaoxiao
    APPLIED THERMAL ENGINEERING, 2018, 130 : 979 - 996
  • [7] THE INLET AIR PRE-COOLING OF NATURAL DRAFT DRY COOLING TOWERS-WETTED MEDIUM ISSUE
    He, Suoying
    Zhang, Guanhong
    Xu, Yi
    Sun, Fengzhong
    PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 1, 2017,
  • [8] Parametric study on spray cooling system for optimising nozzle design with pre-cooling application in natural draft dry cooling towers
    Alkhedhair, Abdullah
    Jahn, Ingo
    Gurgenci, Hal
    Guan, Zhiqiang
    He, Suoying
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2016, 104 : 448 - 460
  • [9] Experimental study of the application of two trickle media for inlet air pre-cooling of natural draft dry cooling towers
    He, Suoying
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    Lu, Yuanshen
    Alkhedhair, Abdullah M.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 644 - 654
  • [10] CFD analysis of pre-cooling water spray system in natural draft dry cooling towers
    Xia, Lin
    Gurgenci, Hal
    Liu, Deyou
    Guan, Zhiqiang
    Zhou, Ling
    Wang, Pei
    APPLIED THERMAL ENGINEERING, 2016, 105 : 1051 - 1060