Longitudinal evaluation of trifocal and extended depth of focus lenses implantation using standard automated perimetry parameters

被引:0
作者
Abe, Ricardo Yuji [1 ]
Barbosa da Silva, Maira Gomes [1 ]
Alves, Thiago Nogueira [1 ]
Tzelikis, Patrick Frensel de M. [1 ]
Hida, Wilson Takashi [1 ]
机构
[1] Hosp Oftalmol Brasilia, Ave L2 Sul,SGAS 607, BR-70200670 Brasilia, DF, Brazil
关键词
Cataract surgery; Multifocal IOLs; PanOptix IOL; Symfony IOL; Visual performance; MULTIFOCAL INTRAOCULAR LENSES; CONTRAST SENSITIVITY; PERFORMANCE; CATARACT;
D O I
10.1007/s10792-022-02526-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate reliability and global indices parameters from standard automated perimetry (SAP) in normal eyes undergoing phacoemulsification cataract surgery with implantation of trifocal or extended depth of focus intraocular lens (IOL). Methods Prospective study to evaluate the effect of trifocal IOL AcrySof IQ PanOptix (R) and extended depth of focus intraocular lens (EDOF) Tecnis Symfony (R) IOL implantation on visual field parameters. Patients underwent SAP pre- and postoperatively. Reliability indices (false negative rate-FN, false positive rate-FP), global indices (foveal sensitivity threshold, visual field index-VFI, standard pattern deviation-PSD, mean deviation MD) and test duration were analyzed. Results A total of 23 eyes from 13 patients were in the trifocal IOL group and a total of 22 eyes from 14 patients were in the EDOF group. The following results were obtained by analyzing pre- and postoperative SAP of EDOF IOL: the rate of change of FN was 1.95/1.41% (p = 0.61); FP 1.64/1.27 (p = 0.60); MD - 1.60/- 1.08 dB (p = 0.15); foveal sensitivity was 34.5/33.9 dB (p = 0.41); VFI 98.5/98.4% (p > 0.99); PSD 1.85/1.86 (p = 0.07); and for test duration 305.81/298.36 s (p = 0.35); all respectively. Analysis of pre- and postoperative parameters of trifocal IOL were the rates of change of FN 1.22/1.83% (p = 0.29); FP 1.65/1.48% (p = 0.95); MD - 1.55/- 1.37 dB (p = 0.19); foveal sensitivity 33.9/34.9 dB (p = 0.47); VFI 98.6/98.3% (p = 0.62); PSD 1.58/2.05 (p = 0.02); and test duration 297.17/298.57 s (p = 0.87); all respectively. Conclusion We identified a change in the PSD parameters in the trifocal IOL group. No other significant changes were identified in SAP parameters after implantation of trifocal AcrySof IQ PanOptix (R) and EDOF Tecnis Symfony (R) IOL. Longitudinal evaluation showed no changes in SAP after Trifocal and EDOF IOL implantation in normal subjects.
引用
收藏
页码:1285 / 1289
页数:5
相关论文
共 50 条
[41]   Real-world evaluation of visual results and patient satisfaction for extended range of focus intraocular lenses compared to trifocal lenses [J].
Laureano A. Rementería-Capelo ;
Jorge L. García-Pérez ;
Juan Gros-Otero ;
Virginia Carrillo ;
Juan Pérez-Lanzac ;
Inés Contreras .
International Ophthalmology, 2021, 41 :163-172
[42]   Visual Acuity, Quality of Vision, and Patient-Reported Outcomes After Bilateral Implantation with a Trifocal or Extended Depth of Focus Intraocular Lens [J].
Tran, Dan B. ;
Owyang, Ashley ;
Hwang, Jin ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2021, 15 :403-412
[43]   Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics [J].
Sakisaka, Toshihiro ;
Minami, Keiichiro ;
Takada, Keita ;
Mori, Yosai ;
Miyata, Kazunori .
BMC OPHTHALMOLOGY, 2021, 21 (01)
[44]   Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics [J].
Toshihiro Sakisaka ;
Keiichiro Minami ;
Keita Takada ;
Yosai Mori ;
Kazunori Miyata .
BMC Ophthalmology, 21
[45]   Laboratory evaluation of the optical properties of two extended-depth-of-focus intraocular lenses [J].
Chae, Sue Hey ;
Son, Hyeck Soo ;
Khoramnia, Ramin ;
Lee, Kyung Heon ;
Choi, Chul Young .
BMC OPHTHALMOLOGY, 2020, 20 (01)
[46]   Evaluation of Visual, Refractive, and Functional Outcomes after Implantation of an Extended Depth of Focus Intraocular Lens in Patients with Stable and Mild Glaucoma [J].
Urcola, Aritz ;
Lauzirika, Gorka ;
Illarramendi, Igor ;
Soto-Velasco, Andrea ;
Sanchez-Avila, Ronald ;
Fuente-Garcia, Carlota ;
Fernandez-Garcia, Aitor .
OPHTHALMOLOGY AND THERAPY, 2025, 14 (05) :1039-1051
[47]   Evaluation of Visual and Patient-Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses [J].
Dolowiec-Kwapisz, Anna ;
Piotrowska, Halina ;
Misiuk-Hojlo, Marta .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
[48]   Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population [J].
Son, Hyeck-Soo ;
Kim, Seong Ho ;
Auffarth, Gerd U. ;
Choi, Chul Young .
BMC OPHTHALMOLOGY, 2019, 19 (01)
[49]   Visual Function after Implantation of Diffractive Extended Depth-of-Focus Intraocular Lenses in Eyes with Primary Open-Angle Glaucoma [J].
Bissen-Miyajima, Hiroko ;
Ota, Yuka ;
Taira, Yoko ;
Takemura, Ryo ;
Minami, Keiichiro .
OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) :3099-3108
[50]   Visual Function after Implantation of Diffractive Extended Depth-of-Focus Intraocular Lenses in Eyes with Primary Open-Angle Glaucoma [J].
Hiroko Bissen-Miyajima ;
Yuka Ota ;
Yoko Taira ;
Ryo Takemura ;
Keiichiro Minami .
Ophthalmology and Therapy, 2023, 12 :3099-3108