摘要
Purpose To evaluate reliability and global indices parameters from standard automated perimetry (SAP) in normal eyes undergoing phacoemulsification cataract surgery with implantation of trifocal or extended depth of focus intraocular lens (IOL). Methods Prospective study to evaluate the effect of trifocal IOL AcrySof IQ PanOptix (R) and extended depth of focus intraocular lens (EDOF) Tecnis Symfony (R) IOL implantation on visual field parameters. Patients underwent SAP pre- and postoperatively. Reliability indices (false negative rate-FN, false positive rate-FP), global indices (foveal sensitivity threshold, visual field index-VFI, standard pattern deviation-PSD, mean deviation MD) and test duration were analyzed. Results A total of 23 eyes from 13 patients were in the trifocal IOL group and a total of 22 eyes from 14 patients were in the EDOF group. The following results were obtained by analyzing pre- and postoperative SAP of EDOF IOL: the rate of change of FN was 1.95/1.41% (p = 0.61); FP 1.64/1.27 (p = 0.60); MD - 1.60/- 1.08 dB (p = 0.15); foveal sensitivity was 34.5/33.9 dB (p = 0.41); VFI 98.5/98.4% (p > 0.99); PSD 1.85/1.86 (p = 0.07); and for test duration 305.81/298.36 s (p = 0.35); all respectively. Analysis of pre- and postoperative parameters of trifocal IOL were the rates of change of FN 1.22/1.83% (p = 0.29); FP 1.65/1.48% (p = 0.95); MD - 1.55/- 1.37 dB (p = 0.19); foveal sensitivity 33.9/34.9 dB (p = 0.47); VFI 98.6/98.3% (p = 0.62); PSD 1.58/2.05 (p = 0.02); and test duration 297.17/298.57 s (p = 0.87); all respectively. Conclusion We identified a change in the PSD parameters in the trifocal IOL group. No other significant changes were identified in SAP parameters after implantation of trifocal AcrySof IQ PanOptix (R) and EDOF Tecnis Symfony (R) IOL. Longitudinal evaluation showed no changes in SAP after Trifocal and EDOF IOL implantation in normal subjects.
引用
收藏
页码:1285 / 1289
页数:5
相关论文
共 50 条
  • [1] Longitudinal evaluation of trifocal and extended depth of focus lenses implantation using standard automated perimetry parameters
    Ricardo Yuji Abe
    Maíra Gomes Barbosa da Silva
    Thiago Nogueira Alves
    Patrick Frensel de M. Tzelikis
    Wilson Takashi Hida
    International Ophthalmology, 2023, 43 : 1285 - 1289
  • [2] A Comparative Evaluation of a New Generation of Diffractive Trifocal and Extended Depth of Focus Intraocular Lenses
    Cochener, Beatrice
    Boutillier, Guillaume
    Lamard, Mathieu
    Auberger-Zagnoli, Claire
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (08) : 507 - +
  • [3] Clinical Outcomes after Bilateral Implantation of Trifocal Diffractive Intraocular Lenses and Extended Depth of Focus Intraocular Lenses
    Shin, Kyoung Yoon
    Lim, Dong Hui
    Chung, Tae-Young
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (19)
  • [4] Influence of implantations of extended depth-of-focus on standard automated perimetry
    Lee, Jinhee
    Mori, Yosai
    Nejima, Ryohei
    Minami, Keiichiro
    Miyata, Kazunori
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] Comparison between bilateral implantation of a trifocal intraocular lens (Alcon Acrysof IQ® PanOptix) and extended depth of focus lens (Tecnis® Symfony® ZXR00 lens)
    Farvardin, Mohsen
    Johari, Mohammadkarim
    Attarzade, Adel
    Rahat, Feisal
    Farvardin, Reza
    Farvardin, Zahra
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (02) : 567 - 573
  • [6] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [7] Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses
    Fang, Xiaoling
    Xue, Wenwen
    Yu, Chunxia
    Tao, Jinhua
    Wang, Yulan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (12) : 3897 - 3903
  • [8] A Comparative Evaluation of Diffractive Trifocal and New Refractive/Extended Depth of Focus Intraocular Lenses for Refractive Lens Exchange
    Ozulken, Kemal
    Kiziltoprak, Hasan
    Yuksel, Erdem
    Mumcuoglu, Tarkan
    CURRENT EYE RESEARCH, 2021, 46 (06) : 811 - 817
  • [9] Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
    McNeely, Richard N.
    Moutari, Salissou
    Stewart, Stephen
    Moore, Jonathan E.
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (12) : 3985 - 3998
  • [10] Visual performance and patient preference with bilateral implantation of an extended depth of focus or combined implantation of an extended depth of focus/trifocal intraocular lens
    Moore, Jonathan
    Ostergaard, Jens
    Kretz, Florian
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)