Motion resilience of the balanced steady-state free precession geometric solution

被引:1
作者
Hoff, Michael N. [1 ]
Xiang, Qing-San [2 ,3 ]
Cross, Nathan M. [4 ]
Hippe, Daniel [5 ]
Andre, Jalal B. [4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 185 Berry St,Suite 380, San Francisco, CA 94107 USA
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[5] Fred Hutchinson Canc Res Ctr, Clin Biostat, 1124 Columbia St, Seattle, WA 98104 USA
关键词
banding artifact; bSSFP imaging; linearized geometric solution; motion artifact; phase cycling; IMAGING SEQUENCES; SPIN-ECHO; PHASE; REMOVAL; MRI;
D O I
10.1002/mrm.29438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Many MRI sequences are sensitive to motion and its associated artifacts. The linearized geometric solution (LGS), a balanced steady-state free precession (bSSFP) off-resonance signal demodulation technique, is evaluated with respect to motion artifact resilience. Theory and Methods The mechanism and extent of LGS motion artifact resilience is examined in simulated, flow phantom, and in vivo clinical imaging. Motion artifact correction capabilities are decoupled from susceptibility artifact correction when feasible to permit controlled analysis of motion artifact correction when comparing the LGS with standard and phase-cycle-averaged (complex sum) bSSFP imaging. Results Simulations reveal that the LGS demonstrates motion artifact reduction capabilities similar to standard clinical bSSFP imaging techniques, with slightly greater resilience in high SNR regions and for shorter-duration motion. Flow phantom experiments assert that the LGS reduces shorter-duration motion artifact error by similar to 24%-65% relative to the complex sum, whereas reconstructions exhibit similar error reduction for constant motion. In vivo analysis demonstrates that in the internal auditory canal/orbits, the LGS was deemed to have less artifact in 24%/49% and similar artifact in 76%/51% of radiological assessments relative to the complex sum, and the LGS had less artifact in 97%/81% and similar artifact in 3%/16% of assessments relative to standard bSSFP. Only 2 of 63 assessments deemed the LGS inferior to either complex sum or standard bSSFP in terms of artifact reduction. Conclusion The LGS provides sufficient bSSFP motion artifact resilience to permit robust elimination of susceptibility artifacts, inspiring its use in a wide variety of applications.
引用
收藏
页码:192 / 204
页数:13
相关论文
共 50 条
  • [1] On the application of balanced steady-state free precession to MR microscopy
    Baer, Sebastien
    Oerther, Thomas
    Weigel, Matthias
    Mueller, Angelina
    Hucker, Patrick
    Korvink, Jan G.
    Ko, Cheng-Wen
    Wapler, Matthias C.
    Leupold, Jochen
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (04) : 437 - 447
  • [2] Artificial neural network for suppression of banding artifacts in balanced steady-state free precession MRI
    Kim, Ki Hwan
    Park, Sung-Hong
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 139 - 146
  • [3] Concomitant gradient field effects in balanced steady-state free precession
    Sica, Christopher T.
    Meyer, Craig H.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 721 - 730
  • [4] Profile-encoding reconstruction for multiple-acquisition balanced steady-state free precession imaging
    Ilicak, Efe
    Senel, Lutfi Kerem
    Biyik, Erdem
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1316 - 1329
  • [5] Intrinsic diffusion sensitivity of the balanced steady-state free precession (bSSFP) imaging sequence
    Baer, Sebastien
    Weigel, Matthias
    von Elverfeldt, Dominik
    Hennig, Juergen
    Leupold, Jochen
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1383 - 1392
  • [6] Analytical Characterization of RF Phase-Cycled Balanced Steady-State Free Precession
    Lauzon, M. Louis
    Frayne, Richard
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2009, 34A (03) : 133 - 143
  • [7] Resting-State fMRI Using Passband Balanced Steady-State Free Precession
    Cheng, Joe S.
    Gao, Patrick P.
    Zhou, Iris Y.
    Chan, Russell W.
    Chan, Queenie
    Mak, Henry K.
    Khong, Pek L.
    Wu, Ed X.
    PLOS ONE, 2014, 9 (03):
  • [8] Spin-Locked Balanced Steady-State Free-Precession (slSSFP)
    Witschey, Walter R. T.
    Borthakur, Ari
    Elliott, Mark A.
    Magland, Jeremy
    McArdle, Erin L.
    Wheaton, Andrew
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 993 - 1001
  • [9] Analytical Solution to the Transient Phase of Steady-State Free Precession Sequences
    Ganter, Carl
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 149 - 164
  • [10] Parameter Estimation Approach to Banding Artifact Reduction in Balanced Steady-State Free Precession
    Bjork, Marcus
    Ingle, R. Reeve
    Gudmundson, Erik
    Stoica, Petre
    Nishimura, Dwight G.
    Barral, Joelle K.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 880 - 892