The Development of a Series of Genomic DNA Reference Materials with Specific Copy Number Ratios for The Detection of Genetically Modified Maize DBN9936

被引:3
作者
Li, Jun [1 ]
Gao, Hongfei [1 ]
Li, Yunjing [1 ]
Zhai, Shanshan [1 ]
Xiao, Fang [1 ]
Wu, Gang [1 ]
Wu, Yuhua [1 ]
机构
[1] Chinese Acad Agr Sci, Oil Crops Res Inst, Key Lab Agr Genet Modified Organisms Traceabil, Minist Agr & Rural Affairs, Wuhan 430062, Peoples R China
关键词
DBN9936; genomic DNA; certified reference material; duplex droplet digital PCR; DIGITAL PCR; QUANTIFICATION; STABILITY;
D O I
10.3390/foods13050747
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The genetically modified (GM) maize DBN9936 with a biosafety certificate will soon undergo commercial application. To monitor the safety of DBN9936 maize, three genomic DNA (gDNA) reference materials (RMs) (DBN9936a, DBN9936b, and DBN9936c) were prepared with nominal copy number ratios of 100%, 3%, and 1% for the DBN9936 event, respectively. DBN9936a was prepared from the leaf tissue gDNA of DBN9936 homozygotes, while DBN9936b and DBN9936c were prepared by the quantitative mixing of gDNA from the leaf tissues of DBN9936 homozygotes and non-GM counterparts. Validated DBN9936/zSSIIb duplex droplet digital PCR was demonstrated to be an accurate reference method for conducting homogeneity study, stability study, and collaborative characterization. The minimum intake for one measurement was determined to be 2 mu L, and the gDNA RMs were stable during transport at 37 degrees C for 14 days and storage at -20 degrees C for 18 months. Each gDNA RM was certified for three property values: DBN9936 event copy number concentration, zSSIIb reference gene copy number concentration, and DBN9936/zSSIIb copy number ratio. The measurement uncertainty of the certified values took the uncertainty components related to possible inhomogeneity, instability, and characterization into account. This batch of gDNA RMs can be used for calibration and quality control when quantifying DBN9936 events.
引用
收藏
页数:14
相关论文
共 33 条
[1]  
[Anonymous], 2019, BiotechnologyRequirements for Evaluating the Performance of Quantification Methods for Nucleic Acid Target SequencesqPCR and dPCR
[2]  
[Anonymous], 2016, General Requirements for the Competence of Reference Material Producers
[3]  
[Anonymous], 2005, ISO/IEC 17025:2017, V2005, P1, DOI DOI 10.1109/IEEESTD.2015.7106438
[4]  
[Anonymous], 2003, Official Journal of the European Union, VL268, P1
[5]  
[Anonymous], 2008, ISO/IEC Guide 98-3:2008 Uncertainty of Measurement-Part 3: Guide to the Expression of Uncertainty in Measurement (GUM1995)
[6]  
[Anonymous], 2020, ISO Guide 17511:2020 In Vitro Diagnostic Medical Devices-Requirements for Establishing Metrological Traceability of Values Assigned to Calibrators, Trueness Control Materials and Human Samples
[7]  
[Anonymous], 2022, Nippon Gene List of GMO Detection Related Products ver. 33
[8]   Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number [J].
Bhat, Somanath ;
Herrmann, Jan ;
Armishaw, Paul ;
Corbisier, Philippe ;
Emslie, Kerry R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) :457-467
[9]   Relative quantification in seed GMO analysis: state of art and bottlenecks [J].
Chaouachi, Maher ;
Berard, Aurelie ;
Said, Khaled .
TRANSGENIC RESEARCH, 2013, 22 (03) :461-476
[10]   Adventitious presence of GMOs: Scientific overview for Canadian grains [J].
Demeke, T. ;
Perry, D. J. ;
Scowcroft, W. R. .
CANADIAN JOURNAL OF PLANT SCIENCE, 2006, 86 (01) :1-23