The effects of respiratory rate and tidal volume on pulse pressure variation in healthy lungs-a generalized additive model approach may help overcome limitations

被引:2
作者
Enevoldsen, Johannes [1 ,2 ]
Brandsborg, Birgitte [2 ]
Juhl-Olsen, Peter [1 ,3 ]
Rees, Stephen Edward [4 ]
Thaysen, Henriette Vind [5 ]
Scheeren, Thomas W. L. [6 ,7 ]
Vistisen, Simon Tilma [1 ,2 ]
机构
[1] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Cardiothorac and Vasc Surg, Anaesthesia Sect, Aarhus, Denmark
[4] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[5] Aarhus Univ Hosp, Dept Surg, Aarhus, Denmark
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, Groningen, Netherlands
[7] Edwards Lifesci, Irvine, CA USA
关键词
Dynamic filling variable; Fluid responsiveness; Hemodynamic monitoring; Heart-lung interaction; Mechanical ventilation; Pulse pressure variation; FLUID RESPONSIVENESS;
D O I
10.1007/s10877-023-01090-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Pulse pressure variation (PPV) is a well-established method for predicting fluid responsiveness in mechanically ventilated patients. The predictive accuracy is, however, disputed for ventilation with low tidal volume (V-T) or low heart-rate-to-respiratory-rate ratio (HR/RR). We investigated the effects of V-T and RR on PPV and on PPV's ability to predict fluid responsiveness. We included patients scheduled for open abdominal surgery. Prior to a 250 ml fluid bolus, we ventilated patients with combinations of V-T from 4 to 10 ml kg(-1) and RR from 10 to 31 min(-1). For each of 10 RR-VT combinations, PPV was derived using both a classic approach and a generalized additive model (GAM) approach. The stroke volume (SV) response to fluid was evaluated using uncalibrated pulse contour analysis. An SV increase > 10% defined fluid responsiveness. Fifty of 52 included patients received a fluid bolus. Ten were fluid responders. For all ventilator settings, fluid responsiveness prediction with PPV was inconclusive with point estimates for the area under the receiver operating characteristics curve between 0.62 and 0.82. Both PPV measures were nearly proportional to VT. Higher RR was associated with lower PPV. Classically derived PPV was affected more by RR than GAM-derived PPV. Correcting PPV for V-T could improve PPV's predictive utility. Low HR/RR has limited effect on GAM-derived PPV, indicating that the low HR/RR limitation is related to how PPV is calculated. We did not demonstrate any benefit of GAM-derived PPV in predicting fluid responsiveness.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 29 条
  • [11] Are confidence intervals better termed "uncertainty intervals"?
    Gelman, Andrew
    Greenland, Sander
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2019, 366
  • [12] Goal-directed haemodynamic therapy during general anaestnesia for noncardiac surgery: a systematic review and meta-analysis
    Jessen, Marie K.
    Vallentin, Mikael F.
    Holmberg, Mathias J.
    Bolther, Maria
    Hansen, Frederik B.
    Holst, Johanne M.
    Magnussen, Andreas
    Hansen, Niklas S.
    Johannsen, Cecilie M.
    Enevoldsen, Johannes
    Jensen, Thomas H.
    Roessler, Lara L.
    Lind, Peter C.
    Klitholm, Maibritt P.
    Eggertsen, Mark A.
    Caap, Philip
    Boye, Caroline
    Dabrowski, Karol M.
    Vormfenne, Lasse
    Hoybye, Maria
    Henriksen, Jeppe
    Karlsson, Carl M.
    Balleby, Ida R.
    Rasmussen, Marie S.
    Paelestik, Kim
    Granfeldt, Asger
    Andersen, Lars W.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (03) : 416 - 433
  • [13] Karippacheril John George, 2013, J Anaesthesiol Clin Pharmacol, V29, P423, DOI 10.4103/0970-9185.117096
  • [14] Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation
    Kim, Hyung Kook
    Pinsky, Michael R.
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (10) : 2858 - 2862
  • [15] Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices
    Lee, Hyung-Chul
    Jung, Chul-Woo
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [16] Pulse Pressure Variation Adjusted by Respiratory Changes in Pleural Pressure, Rather Than by Tidal Volume, Reliably Predicts Fluid Responsiveness in Patients With Acute Respiratory Distress Syndrome
    Liu, Yang
    Wei, Lu-qing
    Li, Guo-qiang
    Yu, Xin
    Li, Guo-feng
    Li, Yu-ming
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (02) : 342 - 351
  • [17] Prevalence and associated factors of knee osteoarthritis in a rural Chinese adult population: an epidemiological survey
    Liu, Yuan
    Zhang, Haifeng
    Liang, Ningxia
    Fan, Weimin
    Li, Jun
    Huang, Zuhu
    Yin, Zhijian
    Wu, Zhijun
    Hu, Jun
    [J]. BMC PUBLIC HEALTH, 2016, 16
  • [18] Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    Marik, Paul E.
    Cavallazzi, Rodrigo
    Vasu, Tajender
    Hirani, Amyn
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (09) : 2642 - 2647
  • [19] Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
    Michard, F
    Chemla, D
    Richard, C
    Wysocki, M
    Pinsky, MR
    Lecarpentier, Y
    Teboul, JL
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : 935 - 939
  • [20] Applicability of pulse pressure variation: how many shades of grey?
    Michard, Frederic
    Chemla, Denis
    Teboul, Jean-Louis
    [J]. CRITICAL CARE, 2015, 19