The effects of respiratory rate and tidal volume on pulse pressure variation in healthy lungs-a generalized additive model approach may help overcome limitations

被引:2
作者
Enevoldsen, Johannes [1 ,2 ]
Brandsborg, Birgitte [2 ]
Juhl-Olsen, Peter [1 ,3 ]
Rees, Stephen Edward [4 ]
Thaysen, Henriette Vind [5 ]
Scheeren, Thomas W. L. [6 ,7 ]
Vistisen, Simon Tilma [1 ,2 ]
机构
[1] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Cardiothorac and Vasc Surg, Anaesthesia Sect, Aarhus, Denmark
[4] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[5] Aarhus Univ Hosp, Dept Surg, Aarhus, Denmark
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, Groningen, Netherlands
[7] Edwards Lifesci, Irvine, CA USA
关键词
Dynamic filling variable; Fluid responsiveness; Hemodynamic monitoring; Heart-lung interaction; Mechanical ventilation; Pulse pressure variation; FLUID RESPONSIVENESS;
D O I
10.1007/s10877-023-01090-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Pulse pressure variation (PPV) is a well-established method for predicting fluid responsiveness in mechanically ventilated patients. The predictive accuracy is, however, disputed for ventilation with low tidal volume (V-T) or low heart-rate-to-respiratory-rate ratio (HR/RR). We investigated the effects of V-T and RR on PPV and on PPV's ability to predict fluid responsiveness. We included patients scheduled for open abdominal surgery. Prior to a 250 ml fluid bolus, we ventilated patients with combinations of V-T from 4 to 10 ml kg(-1) and RR from 10 to 31 min(-1). For each of 10 RR-VT combinations, PPV was derived using both a classic approach and a generalized additive model (GAM) approach. The stroke volume (SV) response to fluid was evaluated using uncalibrated pulse contour analysis. An SV increase > 10% defined fluid responsiveness. Fifty of 52 included patients received a fluid bolus. Ten were fluid responders. For all ventilator settings, fluid responsiveness prediction with PPV was inconclusive with point estimates for the area under the receiver operating characteristics curve between 0.62 and 0.82. Both PPV measures were nearly proportional to VT. Higher RR was associated with lower PPV. Classically derived PPV was affected more by RR than GAM-derived PPV. Correcting PPV for V-T could improve PPV's predictive utility. Low HR/RR has limited effect on GAM-derived PPV, indicating that the low HR/RR limitation is related to how PPV is calculated. We did not demonstrate any benefit of GAM-derived PPV in predicting fluid responsiveness.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 29 条
  • [1] Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
    Alvarado Sanchez, Jorge Ivan
    Caicedo Ruiz, Juan Daniel
    Diaztagle Fernandez, Juan Jose
    Adolfo Ospina-Tascon, Gustavo
    Cruz Martinez, Luis Eduardo
    [J]. CLINICAL MEDICINE INSIGHTS-CIRCULATORY RESPIRATORY AND PULMONARY MEDICINE, 2020, 14
  • [2] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [3] Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.
    Brower, RG
    Matthay, MA
    Morris, A
    Schoenfeld, D
    Thompson, BT
    Wheeler, A
    Wiedemann, HP
    Arroliga, AC
    Fisher, CJ
    Komara, JJ
    Perez-Trepichio, P
    Parsons, PE
    Wolkin, R
    Welsh, C
    Fulkerson, WJ
    MacIntyre, N
    Mallatratt, L
    Sebastian, M
    McConnell, R
    Wilcox, C
    Govert, J
    Thompson, D
    Clemmer, T
    Davis, R
    Orme, J
    Weaver, L
    Grissom, C
    Eskelson, M
    Young, M
    Gooder, V
    McBride, K
    Lawton, C
    d'Hulst, J
    Peerless, JR
    Smith, C
    Brownlee, J
    Pluss, W
    Kallet, R
    Luce, JM
    Gottlieb, J
    Elmer, M
    Girod, A
    Park, P
    Daniel, B
    Gropper, M
    Abraham, E
    Piedalue, F
    Glodowski, J
    Lockrem, J
    McIntyre, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) : 1301 - 1308
  • [4] brms: An R Package for Bayesian Multilevel Models Using Stan
    Buerkner, Paul-Christian
    [J]. JOURNAL OF STATISTICAL SOFTWARE, 2017, 80 (01): : 1 - 28
  • [5] Canty A., 2021, BOOT BOOTSTRAP R S P
  • [6] Stan: A Probabilistic Programming Language
    Carpenter, Bob
    Gelman, Andrew
    Hoffman, Matthew D.
    Lee, Daniel
    Goodrich, Ben
    Betancourt, Michael
    Brubaker, Marcus A.
    Guo, Jiqiang
    Li, Peter
    Riddell, Allen
    [J]. JOURNAL OF STATISTICAL SOFTWARE, 2017, 76 (01): : 1 - 29
  • [7] Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
    De Backer, D
    Heenen, S
    Piagnerelli, M
    Koch, M
    Vincent, JL
    [J]. INTENSIVE CARE MEDICINE, 2005, 31 (04) : 517 - 523
  • [8] Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients
    De Backer, Daniel
    Taccone, Fabio Silvio
    Holsten, Roland
    Ibrahimi, Fayssal
    Vincent, Jean-Louis
    [J]. ANESTHESIOLOGY, 2009, 110 (05) : 1092 - 1097
  • [9] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [10] Using generalized additive models to decompose time series and waveforms, and dissect heart-lung interaction physiology
    Enevoldsen, Johannes
    Simpson, Gavin L.
    Vistisen, Simon T.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (01) : 165 - 177