Correction of motion tracking errors for PET head rigid motion correction

被引:2
作者
Miranda, Alan [1 ]
Kroll, Tina [2 ]
Schweda, Vanessa [2 ]
Staelens, Steven [1 ]
Verhaeghe, Jeroen [1 ]
机构
[1] Univ Antwerp, Mol Imaging Ctr Antwerp, Univ Pl 1, B-2610 Antwerp, Belgium
[2] Forschungszentrum Julich, Inst Neurosci & Med INM 2, Wilhelm Johnen Str, D-52428 Julich, North Rhine Wes, Germany
关键词
PET; motion correction; brain; motion tracking; COMPENSATION;
D O I
10.1088/1361-6560/acec2c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In positron emission tomography (PET) rigid motion correction, erroneous tracking information translates into reduced quality in motion corrected reconstructions. We aim to improve the accuracy of the motion tracking data, to improve the quality of motion corrected reconstructions. Approach. We developed a method for correction of marker/skin displacement over the skull, for tracking methods which require multiple markers attached on the subject head. Additionally, we correct for small magnitude (& SIM;1-2 mm) residual translation tracking errors that can still be present after other corrections. We performed [F-18]FDG scans in awake mice (n = 8) and rats (n = 8), and dynamic [F-18]SynVesT-1 scans in awake mice (n = 8). Head tracking was performed with the point source tracking method, attaching 3-4 radioactive fiducial markers on the animals' heads. List-mode even-by-event motion correction reconstruction was performed using tracking data obtained from the point source tracking method (MC), tracking data corrected for marker displacement (MC-DC), and tracking data with additional correction for residual translation tracking errors (MC-DCT). Image contrast, and the image enhancement metric (IEM, with MC as reference) were calculated in these 3 reconstructions. Main results. In mice [F-18]FDG scans, the contrast increased on average 3% from MC to MC-DC (IEM: 1.01), and 5% from MC to MC-DCT (IEM: 1.02). For mice [F-18]SynVesT-1 scans the contrast increased 6% from MC to MC-DC (IEM: 1.03), and 7% from MC to MC-DCT (IEM: 1.05). In rat [F-18]FDG scans contrast increased 5% (IEM: 1.04), and 9% (IEM: 1.05), respectively. Significance. The methods presented here serve to correct motion tracking errors in PET brain scans, which translates into improved image quality in motion corrected reconstructions.
引用
收藏
页数:11
相关论文
共 18 条
[1]  
Angelis G., 2013, P IEEE NUCL SCI S ME, P1, DOI [10.1109/NSSMIC.2013.6829263, DOI 10.1109/NSSMIC.2013.6829263]
[2]  
Jaya VL., 2013, INT J COMPUT APPL, V79, P1, DOI [10.5120/13766-1620, DOI 10.5120/13766-1620]
[3]   Impact of image-based motion correction on dopamine D3/D2 receptor occupancy—comparison of groupwise and frame-by-frame registration approaches [J].
Jiao J. ;
Searle G.E. ;
Schnabel J.A. ;
Gunn R.N. .
EJNMMI Physics, 2 (1) :1-15
[4]   Real-time 3D motion tracking for small animal brain PET [J].
Kyme, A. Z. ;
Zhou, V. W. ;
Meikle, S. R. ;
Fulton, R. R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10) :2651-2666
[5]   Markerless Motion Tracking of Awake Animals in Positron Emission Tomography [J].
Kyme, Andre ;
Se, Stephen ;
Meikle, Steven ;
Angelis, Georgios ;
Ryder, Will ;
Popovic, Kata ;
Yatigammana, Dylan ;
Fulton, Roger .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (11) :2180-2190
[6]   Motion estimation and correction in SPECT, PET and CT [J].
Kyme, Andre Z. ;
Fulton, Roger R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18)
[7]   Isoflurane and ketamine-xylazine modify pharmacokinetics of [18F]SynVesT-1 in the mouse brain [J].
Miranda, Alan ;
Bertoglio, Daniele ;
De Weerdt, Caro ;
Staelens, Steven ;
Verhaeghe, Jeroen .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2023, 43 (09) :1612-1624
[8]   Translation of Preclinical PET Imaging Findings: Challenges and Motion Correction to Overcome the Confounding Effect of Anesthetics [J].
Miranda, Alan ;
Bertoglio, Daniele ;
Stroobants, Sigrid ;
Staelens, Steven ;
Verhaeghe, Jeroen .
FRONTIERS IN MEDICINE, 2021, 8
[9]   Motion Dependent and Spatially Variant Resolution Modeling for PET Rigid Motion Correction [J].
Miranda, Alan ;
Staelens, Steven ;
Stroobants, Sigrid ;
Verhaeghe, Jeroen .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (07) :2518-2530
[10]   Awake 18F-FDG PET Imaging of Memantine-Induced Brain Activation and Test-Retest in Freely Running Mice [J].
Miranda, Alan ;
Glorie, Dorien ;
Bertoglio, Daniele ;
Vleugels, Jochen ;
De Bruyne, Guido ;
Stroobants, Sigrid ;
Staelens, Steven ;
Verhaeghe, Jeroen .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (06) :844-850