Creating uniform cluster dose spread-out Bragg peaks for proton and carbon beams

被引:0
作者
Ortiz, Ramon [1 ,2 ]
Faddegon, Bruce [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[2] 1600 Divisadero St, San Francisco, CA 94115 USA
基金
美国国家卫生研究院;
关键词
cluster dose; ionization detail; Monte Carlo; nanodosimetry; particle therapy; TRACK STRUCTURE; NANODOSIMETRY; THERAPY; TOPAS; IONS;
D O I
10.1002/mp.16991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPreliminary data have shown a close association of the generalized ionization cluster size dose (in short, cluster dose) with cell survival, independent of particle type, and energy, when cluster dose is derived from an ionization detail parameter preferred for its association with cell survival. Such results suggest cluster dose has the potential to replace RBE-weighted dose in proton and ion beam radiotherapy treatment plan optimization, should a uniform cluster dose lead to comparable biological effects. However, further preclinical investigations are warranted to confirm this premise.PurposeTo present an analytical approach to create uniform cluster dose spread-out Bragg peaks (SOBP) for evaluation of the potential of cluster dose to result in uniform biological effect.MethodsWe modified the coefficients of the Bortfeld and Schlegel weight formula, an analytical method typically used for the creation of radiation dose SOBP in particle therapy, to produce uniform cluster dose SOBP of different widths (1-5 cm) at relevant clinical proton and carbon beam energies. Optimum parameters were found by minimization of the ratio between the maximum and minimum cluster dose in the SOBP region using the Nelder-Mead method.ResultsThe coefficients of the Bortfeld and Schlegel weight formula leading to uniform cluster dose SOBPs were determined for each combination of beam energy and SOBP width studied. The uniformity of the resulting cluster dose SOBPs, calculated as the relative difference between the maximum and minimum cluster dose within the SOBP, was within 0.3%-3.5% for the evaluated proton beams and 1.3%-3.4% for the evaluated carbon beams.ConclusionsThe modifications to the analytical approach to create radiation dose SOBPs resulted in uniform cluster dose proton and carbon SOBPs over a wide range of beam energies and SOBP widths. Such SOBPs should prove valuable in preclinical investigations for the selection of nanodosimetric quantities to be used in proton and ion therapy treatment planning.
引用
收藏
页码:4482 / 4488
页数:7
相关论文
共 41 条
  • [31] Out-of-field Dose for Scanned and Scattered Proton Beams
    Moyers, Michael F.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 456 - 459
  • [32] Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy
    Islam, M. R.
    Collums, T. L.
    Zheng, Y.
    Monson, J.
    Benton, E. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22) : 8235 - 8251
  • [33] Measurement of microdosimetric spectra produced from a 290 MeV/n Spread Out Bragg Peak carbon beam
    Endo, Satoru
    Takada, Masashi
    Tanaka, Hiroki
    Onizuka, Yoshihiko
    Tanaka, Kenichi
    Miyahara, Nobuyuki
    Baba, Hiromi
    Oishi, Ayumu
    Ishikawa, Masayori
    Hoshi, Masaharu
    Kimura, Shinzo
    Minematsu, Masakazu
    Morimune, Yuki
    Kojima, Yasuaki
    Shizuma, Kiyoshi
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2010, 49 (03) : 469 - 475
  • [34] A Nucleoside Anticancer Drug, 1-(3-C-Ethynyl-β-D-Ribo-Pentofuranosyl)Cytosine, Induces Depth-Dependent Enhancement of Tumor Cell Death in Spread-Out Bragg Peak (SOBP) of Proton Beam
    Maeda, Kenichiro
    Yasui, Hironobu
    Yamamori, Tohru
    Matsuura, Taeko
    Takao, Seishin
    Suzuki, Motofumi
    Matsuda, Akira
    Inanami, Osamu
    Shirato, Hiroki
    PLOS ONE, 2016, 11 (11):
  • [35] Influence of the energy spectrum and spatial spread of proton beams used in eye tumor treatment on the depth-dose characteristics
    Konefal, Adam
    Szaflik, Piotr
    Zipper, Wiktor
    NUKLEONIKA, 2010, 55 (03) : 313 - 316
  • [36] Systematics of relative biological effectiveness measurements for proton radiation along the spread out Bragg peak: experimental validation of the local effect model
    Gruen, Rebecca
    Friedrich, Thomas
    Kraemer, Michael
    Scholz, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03) : 890 - 908
  • [37] OUT-OF-FIELD DOSE EQUIVALENTS DELIVERED BY PASSIVELY SCATTERED THERAPEUTIC PROTON BEAMS FOR CLINICALLY RELEVANT FIELD CONFIGURATIONS
    Wroe, Andrew
    Clasie, Ben
    Kooy, Hanne
    Flanz, Jay
    Schulte, Reinhard
    Rosenfeld, Anatoly
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01): : 306 - 313
  • [38] Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water
    Zhao, Qiang
    Zhang, Zheng
    Li, Yang
    2016 THE INTERNATIONAL CONFERENCE ON NANOMATERIAL, SEMICONDUCTOR AND COMPOSITE MATERIALS (ICNSCM 2016), 2016, 65
  • [39] Comparative simulations of neutron dose in soft tissue and phantom materials for proton and carbon ion therapy with actively scanned beams
    Haelg, Roger A.
    Besserer, Juergen
    Schneider, Uwe
    MEDICAL PHYSICS, 2011, 38 (06) : 3149 - 3156
  • [40] Monte Carlo-based Investigation of Absorbed-dose Energy Dependence of Thermoluminescent Dosimeters in Therapeutic Proton and Carbon Ion Beams
    Chattaraj, Arghya
    Mishra, Subhalaxmi
    Selvam, T. Palani
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 148 - 154