Creating uniform cluster dose spread-out Bragg peaks for proton and carbon beams

被引:0
作者
Ortiz, Ramon [1 ,2 ]
Faddegon, Bruce [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[2] 1600 Divisadero St, San Francisco, CA 94115 USA
基金
美国国家卫生研究院;
关键词
cluster dose; ionization detail; Monte Carlo; nanodosimetry; particle therapy; TRACK STRUCTURE; NANODOSIMETRY; THERAPY; TOPAS; IONS;
D O I
10.1002/mp.16991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPreliminary data have shown a close association of the generalized ionization cluster size dose (in short, cluster dose) with cell survival, independent of particle type, and energy, when cluster dose is derived from an ionization detail parameter preferred for its association with cell survival. Such results suggest cluster dose has the potential to replace RBE-weighted dose in proton and ion beam radiotherapy treatment plan optimization, should a uniform cluster dose lead to comparable biological effects. However, further preclinical investigations are warranted to confirm this premise.PurposeTo present an analytical approach to create uniform cluster dose spread-out Bragg peaks (SOBP) for evaluation of the potential of cluster dose to result in uniform biological effect.MethodsWe modified the coefficients of the Bortfeld and Schlegel weight formula, an analytical method typically used for the creation of radiation dose SOBP in particle therapy, to produce uniform cluster dose SOBP of different widths (1-5 cm) at relevant clinical proton and carbon beam energies. Optimum parameters were found by minimization of the ratio between the maximum and minimum cluster dose in the SOBP region using the Nelder-Mead method.ResultsThe coefficients of the Bortfeld and Schlegel weight formula leading to uniform cluster dose SOBPs were determined for each combination of beam energy and SOBP width studied. The uniformity of the resulting cluster dose SOBPs, calculated as the relative difference between the maximum and minimum cluster dose within the SOBP, was within 0.3%-3.5% for the evaluated proton beams and 1.3%-3.4% for the evaluated carbon beams.ConclusionsThe modifications to the analytical approach to create radiation dose SOBPs resulted in uniform cluster dose proton and carbon SOBPs over a wide range of beam energies and SOBP widths. Such SOBPs should prove valuable in preclinical investigations for the selection of nanodosimetric quantities to be used in proton and ion therapy treatment planning.
引用
收藏
页码:4482 / 4488
页数:7
相关论文
共 41 条
  • [1] Creating a spread-out Bragg peak in proton beams
    Jette, David
    Chen, Weimin
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11) : N131 - N138
  • [2] Modifying proton fluence spectra to generate spread-out Bragg peaks with laser accelerated proton beams
    Schell, S.
    Wilkens, J. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) : N459 - N466
  • [3] Simulation of spread-out bragg peaks in proton beams using Geant4/TOPAS
    Velten, Christian
    Tome, Wolfgang A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [4] Comparison of methodologies for creating spread-out Bragg peaks in proton therapy using TOPAS and MCNP codes
    Branco, I. S. L.
    Burin, A. L.
    Pereira, J. J. N.
    Siqueira, P. T. D.
    Shorto, J. M. B.
    Yoriyaz, H.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 211
  • [5] "Broadscale" nanodosimetry: Nanodosimetric track structure quantities increase at distal edge of spread-out proton Bragg peaks
    Rabus, Hans
    Ngcezu, Sonwabile A.
    Braunroth, Thomas
    Nettelbeck, Heidi
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [6] Feasibility study of hybrid inverse planning with transmission beams and single-energy spread-out Bragg peaks for proton FLASH radiotherapy
    Ma, Chaoqiong
    Yang, Xiaofeng
    Chang, Chih-Wei
    Liu, Ruirui
    Bohannon, Duncan
    Lin, Liyong
    Liu, Tian
    Tian, Sibo
    Zhou, Jun
    MEDICAL PHYSICS, 2023, 50 (06) : 3687 - 3700
  • [7] An analytical reconstruction model of the spread-out Bragg peak using laser-accelerated proton beams
    Tao, Li
    Zhu, Kun
    Zhu, Jungao
    Xu, Xiaohan
    Lin, Chen
    Ma, Wenjun
    Lu, Haiyang
    Zhao, Yanying
    Lu, Yuanrong
    Chen, Jia-er
    Yan, Xueqing
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13) : 5200 - 5212
  • [8] Spread-out of Bragg peak of proton beam using Au nanoparticles: A Monte Carlo simulation study
    Talebi, A. S.
    Rajabi, H.
    Talebi, Asra Sadat
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (03): : 697 - 701
  • [9] Investigating the Implications of a Variable RBE on Proton Dose Fractionation Across a Clinical Pencil Beam Scanned Spread-Out Bragg Peak
    Marshall, Thomas I.
    Chaudhary, Pankaj
    Michaelidesova, Anna
    Vachelova, Jana
    Davidkova, Marie
    Vondracek, Vladimir
    Schettino, Giuseppe
    Prise, Kevin M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 70 - 77
  • [10] Designing a range modulator wheel to spread-out the Bragg peak for a passive proton therapy facility
    Jia, S. Bijan
    Romano, F.
    Cirrone, Giuseppe A. P.
    Cuttone, G.
    Hadizadeh, M. H.
    Mowlavi, A. A.
    Raffaele, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 101 - 108