European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability

被引:56
作者
Stergiou, George S. [1 ]
Avolio, Alberto P. [2 ]
Palatini, Paolo [3 ]
Kyriakoulis, Konstantinos G. [1 ]
Schutte, Aletta E. [4 ]
Mieke, Stephan [5 ]
Kollias, Anastasios [1 ]
Parati, Gianfranco [6 ,7 ,8 ]
Asmar, Roland [9 ]
Pantazis, Nikos [10 ]
Stamoulopoulos, Achilleas [10 ]
Asayama, Kei [11 ]
Castiglioni, Paolo [12 ,13 ]
De la Sierra, Alejandro [14 ]
Hahn, Jin-Oh [15 ]
Kario, Kazuomi [16 ]
McManus, Richard J. [17 ]
Myers, Martin [18 ]
Ohkubo, Takayoshi [11 ]
Shroff, Sanjeev G. [19 ,20 ]
Tan, Isabella [21 ]
Wang, Jiguang [22 ]
Zhang, Yuanting [23 ]
Kreutz, Reinhold [24 ]
O'Brien, Eoin [25 ]
Mukkamala, Ramakrishna [26 ,27 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Med, Hypertens Ctr STRIDE 7, Dept Med 3,Sotiria Hosp, 152 Mesogion Ave, Athens 11527, Greece
[2] Macquarie Univ, Macquarie Med Sch, Fac Med Hlth & Human Sci, Sydney, NSW, Australia
[3] Univ Padua, Dept Med, Padua, Italy
[4] Univ New South Wales, George Inst Global Hlth, Sch Populat Hlth, Sydney, NSW, Australia
[5] Phys Tech Bundesanstalt, Berlin, Germany
[6] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[7] S Luca Hosp, Ist Auxol Italiano, Cardiol Unit, IRCCS, Milan, Italy
[8] S Luca Hosp, Dept Cardiovasc Neural & Metab Sci, Milan, Italy
[9] Fdn Med Res Inst, Geneva, Switzerland
[10] Natl & Kapodistrian Univ Athens, Sch Med, Dept Hyg Epidemiol & Med Stat, Athens, Greece
[11] Teikyo Univ, Dept Hyg & Publ Hlth, Sch Med, Tokyo, Japan
[12] IRCCS Fdn Don Carlo Gnocchi Onlus, Milan, Italy
[13] Univ Insubria, Dept Biotechnol & Life Sci DBSV, Varese, Italy
[14] Univ Barcelona, Hosp Mutua Terrassa, Dept Internal Med, Catalonia, Spain
[15] Univ Maryland, Dept Mech Engn, College Pk, MD USA
[16] Jichi Med Univ, Dept Med, Div Cardiovasc Med, Sch Med, Shimotsuke, Tochigi, Japan
[17] Univ Oxford, Nuffield Dept Primary Care Hlth Sci, Oxford, England
[18] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[19] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[20] Univ Pittsburgh, Dept Med, Pittsburgh, PA USA
[21] Macquarie Univ, George Inst Global Hlth, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, NSW, Australia
[22] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Inst Hypertens, Sch Med, Shanghai, Peoples R China
[23] Hong Kong Ctr Cerebrocardiovasc Hlth Engn COCHE, Hong Kong, Peoples R China
[24] Charite Univ Med Berlin, Freie Univ Berlin, Humboldt Univ Berlin, Berlin Inst Hlth,Dept Clin Pharmacol & Toxicol,Ch, Berlin, Germany
[25] Univ Coll Dublin, Conway Inst, Dublin, Ireland
[26] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[27] Univ Pittsburgh, Dept Anesthesiol & Perioperat Med, Pittsburgh, PA USA
基金
美国国家卫生研究院;
关键词
accuracy; blood pressure measurement; cuffless; monitoring; smartphone; smartwatch; validation; wearable; wristband; MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; HYPERTENSION/INTERNATIONAL ORGANIZATION; UNIVERSAL STANDARD; WEARABLE DEVICE; ADVANCEMENT; ASSOCIATION;
D O I
10.1097/HJH.0000000000003483
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: There is intense effort to develop cuffless blood pressure (BP) measuring devices, and several are already on the market claiming that they provide accurate measurements. These devices are heterogeneous in measurement principle, intended use, functions, and calibration, and have special accuracy issues requiring different validation than classic cuff BP monitors. To date, there are no generally accepted protocols for their validation to ensure adequate accuracy for clinical use.Objective: This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability recommends procedures for validating intermittent cuffless BP devices (providing measurements every >30 sec and usually 30-60 min, or upon user initiation), which are most common.Validation procedures: Six validation tests are defined for evaluating different aspects of intermittent cuffless devices: static test (absolute BP accuracy); device position test (hydrostatic pressure effect robustness); treatment test (BP decrease accuracy); awake/asleep test (BP change accuracy); exercise test (BP increase accuracy); and recalibration test (cuff calibration stability over time). Not all these tests are required for a given device. The necessary tests depend on whether the device requires individual user calibration, measures automatically or manually, and takes measurements in more than one position.Conclusion: The validation of cuffless BP devices is complex and needs to be tailored according to their functions and calibration. These ESH recommendations present specific, clinically meaningful, and pragmatic validation procedures for different types of intermittent cuffless devices to ensure that only accurate devices will be used in the evaluation and management of hypertension.
引用
收藏
页码:2074 / 2087
页数:14
相关论文
共 37 条
[1]   Validation of Blood Pressure Measurement Using a Smartwatch in Patients With Parkinson's Disease [J].
Ahn, Jong Hyeon ;
Song, Joomee ;
Choi, Inyoung ;
Youn, Jinyoung ;
Cho, Jin Whan .
FRONTIERS IN NEUROLOGY, 2021, 12
[2]  
[Anonymous], 2014, IEEE Std 1687-2014, P1, DOI DOI 10.1109/IEEESTD.2014.6837414
[3]  
[Anonymous], 2018, 810602 ISO
[4]  
[Anonymous], 2019, 1708A2019 IEEE, V1708a, P1, DOI [10.1109/IEEESTD.2019.8859685, DOI 10.1109/IEEESTD.2019.8859685]
[5]   Cuffless Blood Pressure Devices [J].
Bradley, Corey K. ;
Shimbo, Daichi ;
Colburn, David Alexander ;
Pugliese, Daniel N. ;
Padwal, Raj ;
Sia, Samuel K. ;
Anstey, D. Edmund .
AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (05) :380-387
[6]   Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient Accuracy [J].
Falter, Maarten ;
Scherrenberg, Martijn ;
Driesen, Karen ;
Pieters, Zoe ;
Kaihara, Toshiki ;
Xu, Linqi ;
Caiani, Enrico Gianluca ;
Castiglioni, Paolo ;
Faini, Andrea ;
Parati, Gianfranco ;
Dendale, Paul .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[7]   ERGOMETRY IN THE ASSESSMENT OF ARTERIAL-HYPERTENSION [J].
FRANZ, IW .
CARDIOLOGY, 1985, 72 (03) :147-159
[8]   Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study [J].
Islam, Sheikh Mohammed Shariful ;
Cartledge, Susie ;
Karmakar, Chandan ;
Rawstorn, Jonathan Charles ;
Fraser, Steve F. ;
Chow, Clara ;
Maddison, Ralph .
JMIR MHEALTH AND UHEALTH, 2019, 7 (10)
[9]   A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory Setting [J].
Mieloszyk, Rebecca ;
Twede, Hope ;
Lester, Jonathan ;
Wander, Jeremiah ;
Basu, Sumit ;
Cohn, Gabe ;
Smith, Greg ;
Morris, Dan ;
Gupta, Sidhant ;
Tan, Desney ;
Villar, Nicolas ;
Wolf, Moni ;
Malladi, Sailaja ;
Mickelson, Matt ;
Ryan, Lauren ;
Kim, Lindsey ;
Kepple, Jeffrey ;
Kirchner, Susanne ;
Wampler, Emma ;
Terada, Riena ;
Robinson, Joel ;
Paulsen, Ron ;
Saponas, T. Scott .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (07) :2864-2875
[10]   The Microsoft Research Aurora Project: Important Findings on Cuffless Blood Pressure Measurement [J].
Mukkamala, Ramakrishna ;
Shroff, Sanjeev G. ;
Landry, Cederick ;
Kyriakoulis, Konstantinos G. ;
Avolio, Alberto P. ;
Stergiou, George S. .
HYPERTENSION, 2023, 80 (03) :534-540