Double cross magnetic wall decoupling for quadrature transceiver RF array coils using common-mode differential-mode resonators

被引:4
作者
Payne, Komlan [1 ]
Bhosale, Aditya Ashok [1 ]
Zhang, Xiaoliang [1 ,2 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[2] SUNY Buffalo, Dept Elect Engn, Buffalo, NY 14260 USA
基金
美国国家卫生研究院;
关键词
High; low-impedance coil; Magnetic resonance imaging; Microstrip transmission line resonator; Parallel MRI; RF coil; Ultra-high field; ISOLATION ENHANCEMENT; SURFACE COIL; DESIGN; MRI; TRANSMIT; ANTENNAS;
D O I
10.1016/j.jmr.2023.107498
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In contrast to linearly polarized RF coil arrays, quadrature transceiver coil arrays are capable of improving signal-to-noise ratio (SNR), spatial resolution, and parallel imaging performance. Owing to a reduced excitation power, a low specific absorption rate can also be obtained using quadrature RF coils. However, due to the complex nature of their structure and their electromagnetic properties, it is challenging to achieve sufficient electromagnetic decoupling while designing multichannel quadrature RF coil arrays, particularly in ultra-high fields. In this work, we proposed a double-cross magnetic wall decoupling for quadrature transceiver RF arrays and implemented the decoupling method on common-mode differential mode quadrature (CMDM) quadrature transceiver arrays at an ultrahigh field of 7 T. The proposed magnetic decoupling wall, comprised of two intrinsically decoupled loops, is used to reduce the mutual coupling between all the multi-mode currents present in the quadrature CMDM array. The decoupling network has no physical connection with the CMDMs' resonators, which provides less design constraint over size-adjustable RF arrays. To validate the feasibility of the proposed crossmagnetic decoupling wall, systematic studies on the decoupling performance based on the impedance of two intrinsic loops are numerically performed. A pair of quadrature transceiver CMDMs is constructed along with the proposed decoupling network, and their scattering matrix is characterized using a network analyzer. The measured results indicate that all the current modes from coupling are simultaneously suppressed using the proposed cross-magnetic wall. Moreover, field distribution and local specific absorption rate (SAR) are numerically obtained for a well-decoupled 8-channel quadrature knee-coil array.
引用
收藏
页数:8
相关论文
共 49 条
  • [1] Mutual Coupling Reduction of a Circularly Polarized MIMO Antenna Using Parasitic Elements and DGS for V2X Communications
    Abu Sufian, Md
    Hussain, Niamat
    Abbas, Anees
    Lee, Jaemin
    Park, Seong Gyoon
    Kim, Nam
    [J]. IEEE ACCESS, 2022, 10 : 56388 - 56400
  • [2] Transmit and receive transmission line arrays for 7 tesla parallel imaging
    Adriany, G
    Van de Moortele, PF
    Wiesinger, F
    Moeller, S
    Strupp, JP
    Andersen, P
    Snyder, C
    Zhang, XL
    Chen, W
    Pruessmann, KP
    Boesiger, P
    Vaughan, T
    Ugurbil, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 434 - 445
  • [3] Analytical modeling provides new insight into complex mutual coupling between surface loops at ultrahigh fields
    Avdievich, N. I.
    Pfrommer, A.
    Giapitzakis, I. A.
    Henning, A.
    [J]. NMR IN BIOMEDICINE, 2017, 30 (10)
  • [4] Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance
    Avdievich, Nikolai I.
    Pan, Jullie W.
    Hetherington, Hoby P.
    [J]. NMR IN BIOMEDICINE, 2013, 26 (11) : 1547 - 1554
  • [5] Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils
    Brizi, Danilo
    Fontana, Nunzia
    Costa, Filippo
    Tiberi, Gianluigi
    Galante, Angelo
    Alecci, Marcello
    Monorchio, Agostino
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (10) : 2806 - 2816
  • [6] Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
    Collins, CM
    Yang, QX
    Wang, JH
    Zhang, X
    Liu, H
    Michaeli, S
    Zhu, XH
    Adriany, G
    Vaughan, JT
    Anderson, P
    Merkle, H
    Ugurbil, K
    Smith, MB
    Chen, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 1026 - 1028
  • [7] MRI RF Array Decoupling Method With Magnetic Wall Distributed Filters
    Connell, Ian R. O.
    Gilbert, Kyle M.
    Abou-Khousa, Mohamed A.
    Menon, Ravi S.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (04) : 825 - 835
  • [8] COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING
    GLOVER, GH
    HAYES, CE
    PELC, NJ
    EDELSTEIN, WA
    MUELLER, OM
    HART, HR
    HARDY, CJ
    ODONNELL, M
    BARBER, WD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) : 255 - 270
  • [9] The development of the birdcage resonator: a historical perspective
    Hayes, Cecil E.
    [J]. NMR IN BIOMEDICINE, 2009, 22 (09) : 908 - 918
  • [10] QUADRATURE DETECTION IN THE LABORATORY FRAME
    HOULT, DI
    CHEN, CN
    SANK, VJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (03) : 339 - 353