Comparative energy analysis of cooling energy performance between conventional and hybrid air source internet data center cooling system

被引:4
作者
Lamptey, Nicholas Boafo [1 ]
Anka, Selorm Kwaku [1 ]
Cho, Yong [3 ]
Lee, Kwang Ho [2 ]
Choi, Jong Woong [3 ]
Choi, Jong Min [4 ]
机构
[1] Hanbat Natl Univ, Grad Sch Dept Mech Engn, Dept Mech Engn, Daejeon 34158, South Korea
[2] Korea Univ, Dept Architecture, Seoul 02741, South Korea
[3] K Water, Res Inst, Daejeon 34045, South Korea
[4] Hanbat Natl Univ, Dept Mech Engn, Daejeon 34158, South Korea
基金
新加坡国家研究基金会;
关键词
Data center; Coefficient of performance; Performance curve; Hybrid cooling; Part load ratio; COMPRESSION REFRIGERATION; SIDE ECONOMIZERS; HEAT-PIPE; EFFICIENCY; THERMOSIPHON; SIMULATION; DRIVEN; PUMP;
D O I
10.1016/j.enbuild.2023.113759
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The widespread need for data processing has led to an increase in internet data centers (IDCs), contributing to the generation of high heat loads and high energy usage. This study discusses a simulation model of a newly proposed cooling system applied to data centers for five selected climatic areas in South Korea. Using experimental data of the newly proposed system, performance correlations are developed by regression analysis method to estimate performance curve coefficients for energy modelling and simulation to predict the annual energy performance of the system and compare the performance with that of a conventional cooling system. The results showed an overall annual average energy efficiency of approximately 14.1% of the hybrid cooling system over the conventional cooling system. The mean seasonal coefficient of performance (SCOP) for the hybrid system and the conventional system is approximately 6.7 and 4.9 respectively for all cases in the winter period while a SCOP of 3.2 and 3.7 respectively for the summer period.
引用
收藏
页数:14
相关论文
共 21 条
  • [11] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 103 - 112
  • [12] Field study on the performance of a thermosyphon and mechanical refrigeration hybrid cooling system in a 5G telecommunication base station
    Meng, Fanxi
    Zhang, Quan
    Lin, Yaolin
    Zou, Sikai
    Fu, Jiyao
    Liu, Baochang
    Wang, Wei
    Ma, Xiaowei
    Du, Sheng
    [J]. ENERGY, 2022, 252
  • [14] Energy efficiency and renewable energy integration in data centres. Strategies and modelling review
    Oro, Eduard
    Depoorter, Victor
    Garcia, Albert
    Salom, Jaume
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 42 : 429 - 445
  • [15] Potential of air-side economizers for data center cooling: A case study for key Australian cities
    Siriwardana, Jayantha
    Jayasekara, Saliya
    Halgamuge, Saman K.
    [J]. APPLIED ENERGY, 2013, 104 : 207 - 219
  • [16] Research of an integrated cooling system consisted of compression refrigeration and pump-driven heat pipe for data centers
    Sun, Yutao
    Wang, Tiejun
    Yang, Lei
    Hu, Liwen
    Zeng, Xiaocheng
    [J]. ENERGY AND BUILDINGS, 2019, 187 : 16 - 23
  • [17] Analysis on energy efficiency of an integrated heat pipe system in data centers
    Wang, Zhenying
    Zhang, Xiaotong
    Li, Zhen
    Luo, Ming
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 937 - 944
  • [18] Experimental analysis of a novel cooling system driven by liquid refrigerant pump and vapor compressor
    Yan, Gang
    Feng, Yongbin
    Peng, Leqin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 11 - 18
  • [19] Numerical investigation of a CO2 loop thermosyphon in an integrated air conditioning system for free cooling of data centers
    Zhang, Hainan
    Shao, Shuangquan
    Jin, Tingxiang
    Tian, Changqing
    [J]. APPLIED THERMAL ENGINEERING, 2017, 126 : 1134 - 1140
  • [20] Performance analysis on hybrid system of thermosyphon free cooling and vapor compression refrigeration for data centers in different climate zones of China
    Zhang, Hainan
    Shao, Shuangquan
    Zou, Huiming
    Tian, Changqing
    [J]. INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 428 - 431