A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers

被引:2
作者
Lopez-Munoz, Alfredo [1 ,2 ]
Lopez-Castano, Isabel [1 ]
Torres-Parejo, Ursula [3 ]
Garcia-Romera, Marta-C. [1 ]
机构
[1] Univ Seville, Pharm Sch, Dept Phys Condensed Matter, Opt Area,Vis Sci Res Grp CIVIUS, Seville 41009, Spain
[2] Miranza Virgen de Lujan, Res & Dev Dept, Seville 41011, Spain
[3] Univ Granada, Dept Stat & Operat Res, Granada 18071, Spain
来源
LIFE-BASEL | 2023年 / 13卷 / 12期
关键词
myopia; soft contact lenses; corneal biomechanics; Scheimpflug technology; Corvis ST (R); COLLAGEN CROSS-LINKING; INTRAOCULAR-PRESSURE; SHORT-TERM; RESPONSE PARAMETERS; THICKNESS;
D O I
10.3390/life13122313
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST (R) (CST, Oculus Optikgerate GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 +/- 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
引用
收藏
页数:14
相关论文
共 47 条
  • [1] Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear
    Alba-Bueno, Francisco
    Beltran-Masgoret, Angel
    Sanjuan, Cristian
    Biarnes, Marc
    Marin, Jesus
    [J]. CONTACT LENS & ANTERIOR EYE, 2009, 32 (02) : 88 - 92
  • [2] Alipour Fateme, 2017, J Ophthalmic Vis Res, V12, P193, DOI 10.4103/jovr.jovr_159_16
  • [3] Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes
    Alvani, Azam
    Hashemi, Hassan
    Pakravan, Mohammad
    Mahbod, Mirgholamreza
    Amanzadeh, Kazem
    Seyedian, Mohammad Amin
    Yaseri, Mehdi
    Jafarzadehpur, Ebrahim
    Fotouhi, Akbar
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2021, 41 (02) : 414 - 423
  • [4] Ambrosio Jr R, 2017, INT J KERATOCONUS EC, V6, P23, DOI 10.5005/jp-journals-10025-1139
  • [5] Ambrosio Renato Jr, 2017, Open Ophthalmol J, V11, P176, DOI 10.2174/1874364101711010176
  • [6] Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
    Ambrosio, Renato, Jr.
    Ramos, Isaac
    Luz, Allan
    Faria, Fernando Correa
    Steinmueller, Andreas
    Krug, Matthias
    Belin, Michael W.
    Roberts, Cynthia Jane
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 99 - 102
  • [7] Statistical guidelines for the analysis of data obtained from one or both eyes
    Armstrong, Richard A.
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (01) : 7 - 14
  • [8] Effect of contact lens wear on central corneal thickness measurements
    Braun, DA
    Penno, EEA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07) : 1319 - 1322
  • [9] The Effect of Contact Lens Usage on Corneal Biomechanical Parameters in Myopic Patients
    Cankaya, Ali B.
    Beyazyildiz, Emrullah
    Ileri, Dilek
    Ozturk, Faruk
    [J]. CORNEA, 2012, 31 (07) : 764 - 769
  • [10] Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters?
    Cavdarli, Cemal
    Topcu-Yilmaz, Pinar
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (04): : 166 - 170