Computerized cardiotocography analysis during labor - A state-of-the-art review

被引:11
作者
Ben M'Barek, Imane [1 ,2 ,3 ,6 ]
Jauvion, Gregoire [4 ]
Ceccaldi, Pierre-Francois [2 ,3 ,5 ]
机构
[1] Hop Beaujon, Assistance Publ Hop Paris, Dept Obstet & Gynecol, Clichy La Garenne, France
[2] Univ Paris Cite, Paris, France
[3] Univ Paris Cite, Hlth Simulat Dept, iLumens, Paris, France
[4] Genos Care, Paris, France
[5] Hop Foch, Dept Gynecol Obstet & Reprod Med, Suresnes, France
[6] Hop Beaujon, Serv Gynecol Obstet, 100 Blvd Gen Leclerc, Clichy La Garenne, France
关键词
cardiotocography deep learning; cardiotocography machine learning; computerized cardiotocography; fetal heart rate monitoring; fetal hypoxia; perinatal morbidity; FETAL HEART-RATE; BASE-LINE ESTIMATION; INTRAPARTUM CARDIOTOCOGRAM; NEONATAL OUTCOMES; GUIDELINES; AGREEMENT; CONSENSUS; SIGNALS; CTG;
D O I
10.1111/aogs.14498
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Cardiotocography is defined as the recording of fetal heart rate and uterine contractions and is widely used during labor as a screening tool to determine fetal wellbeing. The visual interpretation of the cardiotocography signals by the practitioners, following common guidelines, is subject to a high interobserver variability, and the efficiency of cardiotocography monitoring is still debated. Since the 1990s, researchers and practitioners work on designing reliable computer-aided systems to assist practitioners in cardiotocography interpretation during labor. Several systems are integrated in the monitoring devices, mostly based on the guidelines, but they have not clearly demonstrated yet their usefulness. In the last decade, the availability of large clinical databases as well as the emergence of machine learning and deep learning methods in healthcare has led to a surge of studies applying those methods to cardiotocography signals analysis. The state-of-the-art systems perform well to detect fetal hypoxia when evaluated on retrospective cohorts, but several challenges remain to be tackled before they can be used in clinical practice. First, the development and sharing of large, open and anonymized multicentric databases of perinatal and cardiotocography data during labor is required to build more accurate systems. Also, the systems must produce interpretable indicators along with the prediction of the risk of fetal hypoxia in order to be appropriated and trusted by practitioners. Finally, common standards should be built and agreed on to evaluate and compare those systems on retrospective cohorts and to validate their use in clinical practice.
引用
收藏
页码:130 / 137
页数:8
相关论文
共 64 条
[1]   Sparse learning for Intrapartum fetal heart rate analysis [J].
Abry, P. ;
Spilka, J. ;
Leonarduzzi, R. ;
Chudacek, V. ;
Pustelnik, N. ;
Doret, M. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (03)
[2]  
Ahmad MA, 2018, ACM-BCB'18: PROCEEDINGS OF THE 2018 ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY, AND HEALTH INFORMATICS, P559, DOI [10.1145/3233547.3233667, 10.1109/ICHI.2018.00095]
[3]   Effectiveness of intrapartum fetal surveillance to improve maternal and neonatal outcomes: a systematic review and network meta-analysis [J].
Al Wattar, Bassel H. ;
Honess, Emma ;
Bunnewell, Sarah ;
Welton, Nicky J. ;
Quenby, Siobhan ;
Khan, Khalid S. ;
Zamora, Javier ;
Thangaratinam, Shakila .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (14) :E468-E477
[4]   Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour [J].
Alfirevic, Z. ;
Devane, D. ;
Gyte, G. M. L. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (03)
[5]  
American College of Obstetricians and Gynecologists, 1974, ACOG Tech Bull, V32
[6]  
Ayres-de Campos D, 2000, J Matern Fetal Med, V9, P311
[7]   Comparison of fetal heart rate baseline estimation by SisPorto® 2.01 and a consensus of clinicians [J].
Ayres-De-Campos, D ;
Bernardes, J .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 117 (02) :174-178
[8]   SisPorto 4.0-computer analysis following the 2015 FIGO Guidelines for intrapartum fetal monitoring [J].
Ayres-de-Campos, Diogo ;
Rei, Mariana ;
Nunes, Ines ;
Sousa, Paulo ;
Bernardes, Joao .
JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (01) :62-67
[9]   FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography [J].
Ayres-de-Campos, Diogo ;
Spong, Catherine Y. ;
Chandraharan, Edwin .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2015, 131 (01) :13-24
[10]   Omniview-SisPorto® 3.5 -: a central fetal monitoring station with online alerts based on computerized cardiotocogram plus ST event analysis [J].
Ayres-de-Campos, Diogo ;
Sousa, Paulo ;
Costa, Antonia ;
Bernardes, Joao .
JOURNAL OF PERINATAL MEDICINE, 2008, 36 (03) :260-264