Effect of micro-CT acquisition parameters and individual analysis on the assessment of bone repair

被引:3
作者
Irie, Milena Suemi [1 ]
Spin-Neto, Rubens [2 ]
Souza Teixeira, Lucas Henrique [1 ]
Rabelo, Gustavo Davi [3 ]
de Araujo Reis, Nayara Teixeira [1 ]
Ferreira Soares, Priscilla Barbosa [1 ]
机构
[1] Univ Fed Uberlandia UFU, Sch Dent, Dept Periodontol & Implantol, Uberlandia, MG, Brazil
[2] Aarhus Univ, Dept Dent & Oral Hlth, Hlth, Aarhus, Denmark
[3] Univ Fed Santa Catarina, Dent Dept, Florianopolis, SC, Brazil
关键词
X-Ray Microtomography; Bone and Bones; Wound Healing; Models; Animal; Cancellous Bone; COMPUTED-TOMOGRAPHY; CANCELLOUS BONE; VOXEL SIZE; SEGMENTATION; RESOLUTION; VIVO; ACCURACY; VOLUME;
D O I
10.1590/1807-3107bor-2023.vol37.0099
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-mu m and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 mu m for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-mu m voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-mu m voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-mu m voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-mu m voxel size compared with 6 mu m (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.
引用
收藏
页数:8
相关论文
共 25 条
[1]   Bone Remodeling in Onlay Beta-Tricalcium Phosphate and Coral Grafts to Rat Calvaria: Microcomputerized Tomography Analysis [J].
Anavi, Yakir ;
Avishai, Gal ;
Calderon, Shlomo ;
Allon, Dror M. .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) :379-386
[2]   Automated Quantitative Bone Analysis in In Vivo X-ray Micro-Computed Tomography [J].
Behrooz, Ali ;
Kask, Peet ;
Meganck, Jeff ;
Kempner, Joshua .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) :1955-1965
[3]   Fully automated segmentation of callus by micro-CT compared to biomechanics [J].
Bissinger, Oliver ;
Goetz, Carolin ;
Wolff, Klaus-Dietrich ;
Hapfelmeier, Alexander ;
Prodinger, Peter Michael ;
Tischer, Thomas .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
[4]   Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[5]   Clinical Device-Related Article Micro-Computed Tomographic Analysis of Bone Healing Subsequent to Graft Placement [J].
Chopra, Preeti M. ;
Johnson, Maria ;
Nagy, Tim R. ;
Lemons, Jack E. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (02) :611-618
[6]  
Christiansen Blaine A, 2016, Bone Rep, V5, P136, DOI 10.1016/j.bonr.2016.05.006
[7]   Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[8]  
Dufresne T, 1998, Technol Health Care, V6, P351
[9]   Segmentation of cancellous bone from high-resolution computed tomography images: Influence on trablecular bone measurements [J].
Elmoutaouakkil, A ;
Peyrin, F ;
Elkafi, J ;
Laval-Jeantet, AM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) :354-362
[10]   Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis [J].
Gaeta-Araujo, Hugo ;
Oliveira-Santos, Nicolly ;
Brasil, Danieli Moura ;
Leandro do Nascimento, Eduarda Helena ;
Madlum, Daniela Verardi ;
Haiter-Neto, Francisco ;
de Oliveira-Santos, Christiano .
DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (08)