Affinity-based electrochemical sensors for biomolecular detection in whole blood

被引:24
作者
Wilkirson, Elizabeth C. [1 ]
Singampalli, Kavya L. [2 ,3 ]
Li, Jiran [1 ]
Dixit, Desh Deepak [1 ]
Jiang, Xue [1 ]
Gonzalez, Diego H. [2 ]
Lillehoj, Peter B. [1 ,2 ]
机构
[1] Rice Univ, Dept Mech Engn, 6100 Main St, Houston, TX 77005 USA
[2] Rice Univ, Dept Bioengn, 6500 Main St, Houston, TX 77030 USA
[3] Baylor Coll Med, Med Scientist Training Program, 1 Baylor Plaza, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
Electrochemical; Biosensor; Immunosensor; Whole blood; Diagnostics; TUMOR-NECROSIS-FACTOR; IMMUNOASSAY SYSTEM; MAGNETIC BEADS; NT-PROBNP; BIOSENSORS; CARE; PLASMA; MICROFLUIDICS; NANOMATERIALS; IMMUNOSENSOR;
D O I
10.1007/s00216-023-04627-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection and/or quantification of biomarkers in blood is important for the early detection, diagnosis, and treatment of a variety of diseases and medical conditions. Among the different types of sensors for detecting molecular biomarkers, such as proteins, nucleic acids, and small-molecule drugs, affinity-based electrochemical sensors offer the advantages of high analytical sensitivity and specificity, fast detection times, simple operation, and portability. However, biomolecular detection in whole blood is challenging due to its highly complex matrix, necessitating sample purification (i.e., centrifugation), which involves the use of bulky, expensive equipment and tedious sample-handling procedures. To address these challenges, various strategies have been employed, such as purifying the blood sample directly on the sensor, employing micro-/nanoparticles to enhance the detection signal, and coating the electrode surface with blocking agents to reduce nonspecific binding, to improve the analytical performance of affinity-based electrochemical sensors without requiring sample pre-processing steps or laboratory equipment. In this article, we present an overview of affinity-based electrochemical sensor technologies that employ these strategies for biomolecular detection in whole blood.
引用
收藏
页码:3983 / 4002
页数:20
相关论文
共 90 条
  • [51] A Highly Selective Electrochemical DNA-Based Sensor That Employs Steric Hindrance Effects to Detect Proteins Directly in Whole Blood
    Mahshid, Sahar Sadat
    Camire, Sebastien
    Ricci, Francesco
    Vallee-Belisle, Alexis
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2015, 137 (50) : 15596 - 15599
  • [52] Adaptive release of heparin from anticoagulant hydrogels triggered by different blood coagulation factors
    Maitz, Manfred F.
    Zitzmann, Jan
    Hanke, Jasmin
    Renneberg, Claudia
    Tsurkan, Mikhail V.
    Sperling, Claudia
    Freudenberg, Uwe
    Werner, Carsten
    [J]. BIOMATERIALS, 2017, 135 : 53 - 61
  • [53] Malik P., 2021, MEAS SENS, V16, P100050, DOI [10.1016/j.measen.2021.100050, DOI 10.1016/J.MEASEN.2021.100050]
  • [54] Capillary flow-driven microfluidic device with wettability gradient and sedimentation effects for blood plasma separation
    Maria, M. Sneha
    Rakesh, P. E.
    Chandra, T. S.
    Sen, A. K.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [55] Microfluidic blood plasma separation for medical diagnostics: is it worth it?
    Mielczarek, W. S.
    Obaje, E. A.
    Bachmann, T. T.
    Kersaudy-Kerhoas, M.
    [J]. LAB ON A CHIP, 2016, 16 (18) : 3441 - 3448
  • [56] An array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples
    Molinero-Fernandez, Agueda
    Moreno-Guzman, Maria
    Lopez, Miguel angel
    Escarpa, Alberto
    [J]. MICROCHEMICAL JOURNAL, 2020, 157
  • [57] Giant intrinsic carrier mobilities in graphene and its bilayer
    Morozov, S. V.
    Novoselov, K. S.
    Katsnelson, M. I.
    Schedin, F.
    Elias, D. C.
    Jaszczak, J. A.
    Geim, A. K.
    [J]. PHYSICAL REVIEW LETTERS, 2008, 100 (01)
  • [58] Accuracy and reliability of the i-STAT point-of-care device for the determination of haemoglobin concentration before and after major blood loss
    Ng, W. L.
    Short, T. G.
    Gunn, K. N.
    Fuge, G. S.
    Slon, B.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (04) : 495 - 499
  • [59] Point-of-care nucleic acid testing for infectious diseases
    Niemz, Angelika
    Ferguson, Tanya M.
    Boyle, David S.
    [J]. TRENDS IN BIOTECHNOLOGY, 2011, 29 (05) : 240 - 250
  • [60] Magnetic Beads-Based Electrochemical Sensors Applied to the Detection and Quantification of Bioterrorism/Biohazard Agents
    Pedrero, Maria
    Campuzano, Susana
    Pingarron, Jose M.
    [J]. ELECTROANALYSIS, 2012, 24 (03) : 470 - 482