Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI

被引:14
作者
Kilinc, Ozden [1 ]
Chu, Stanley [1 ]
Baraboo, Justin [1 ,2 ]
Weiss, Elizabeth K. [1 ,2 ]
Engel, Joshua [1 ]
Maroun, Anthony [1 ]
Giese, Daniel [3 ,4 ]
Jin, Ning [5 ]
Chow, Kelvin [1 ,6 ]
Bi, Xiaoming [6 ]
Davids, Rachel [6 ]
Mehta, Christopher [7 ]
Malaisrie, S. Chris [7 ]
Hoel, Andrew [8 ]
Carr, James [1 ]
Markl, Michael [1 ,2 ]
Allen, Bradley D. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL USA
[3] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, Erlangen, Germany
[5] Siemens Med Solut USA Inc, Cardiovasc MR R&D, Cleveland, OH USA
[6] Siemens Med Solut USA Inc, Cardiovasc MR R&D, Chicago, IL USA
[7] Northwestern Univ, Dept Surg Cardiac Surg, Chicago, IL USA
[8] Northwestern Univ, Dept Surg Vasc Surg, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
4D Flow; MRI; aorta; dissection; hemodynamics; flow; EXPERT CONSENSUS DOCUMENT; PHASE-CONTRAST MR; GROWTH; TEVAR;
D O I
10.1002/jmri.28432
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD). Purpose To investigate CS-accelerated 4D Flow MRI performance compared to GRAPP-accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD. Study Type Prospective. Population Twelve TBAD patients, two volunteers. Field Strength/Sequence 1.5T, 3D time-resolved cine phase-contrast gradient echo sequence. Assessment GRAPPA (acceleration factor [R] = 2) and two CS-accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane-based mid-lumen flows were quantified. Imaging times were recorded. Tests Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance. Results The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781-0.986]), and low to strong in FL (r = [0.347-0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732-0.989). The FF and net flow in mid-descending aorta TL were significantly different between CS7.7 and CS10.2. Conclusion CS-accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS-acceleration impacts KE, FF, RF, and stasis more in FL. Evidence Level: 1 Technical Efficacy: Stage 2
引用
收藏
页码:1752 / 1763
页数:12
相关论文
共 35 条
[21]   Evaluation of Valvular Insufficiency and Shunts with Parallel-imaging Compressed-sensing 4D Phase-contrast MR Imaging with Stereoscopic 3D Velocity-fusion Volume-rendered Visualization [J].
Hsiao, Albert ;
Lustig, Michael ;
Alley, Marcus T. ;
Murphy, Mark J. ;
Vasanawala, Shreyas S. .
RADIOLOGY, 2012, 265 (01) :87-95
[22]   Parametric Hemodynamic 4D Flow MRI Maps for the Characterization of Chronic Thoracic Descending Aortic Dissection [J].
Jarvis, Kelly ;
Pruijssen, Judith T. ;
Son, Andre Y. ;
Allen, Bradley D. ;
Soulat, Gilles ;
Vali, Alireza ;
Barker, Alex J. ;
Hoel, Andrew W. ;
Eskandari, Mark K. ;
Malaisrie, S. Chris ;
Carr, James C. ;
Collins, Jeremy D. ;
Markl, Michael .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (05) :1357-1368
[23]   Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction [J].
Ma, Liliana E. ;
Markl, Michael ;
Chow, Kelvin ;
Huh, Hyungkyu ;
Forman, Christoph ;
Vali, Alireza ;
Greiser, Andreas ;
Carr, James ;
Schnell, Susanne ;
Barker, Alex J. ;
Jin, Ning .
MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) :3675-3690
[24]   Updates on Indications for TEVAR in Type B Aortic Dissection [J].
Malaisrie, S. Chris ;
Mehta, Christopher K. .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2020, 15 (06) :495-501
[25]   2021 The American Association for Thoracic Surgery expert consensus document: Surgical treatment of acute type A aortic dissection [J].
Malaisrie, S. Christopher ;
Szeto, Wilson Y. ;
Halas, Monika ;
Girardi, Leonard N. ;
Coselli, Joseph S. ;
Sundt, Thoralf M., III ;
Chen, Edward P. ;
Fischbein, Michael P. ;
Gleason, Thomas G. ;
Okita, Yutaka ;
Ouzounian, Maral ;
Patel, Himanshu J. ;
Roselli, Eric E. ;
Shrestha, Malakh L. ;
Svensson, Lars G. ;
Moon, Marc R. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 162 (03) :735-+
[26]   False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth [J].
Marlevi, David ;
Sotelo, Julio A. ;
Grogan-Kaylor, Ross ;
Ahmed, Yunus ;
Uribe, Sergio ;
Patel, Himanshu J. ;
Edelman, Elazer R. ;
Nordsletten, David A. ;
Burris, Nicholas S. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
[27]   Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration [J].
Neuhaus, Elisabeth ;
Weiss, Kilian ;
Bastkowski, Rene ;
Koopmann, Jonas ;
Maintz, David ;
Giese, Daniel .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
[28]   Highly accelerated aortic 4D flow MRI using compressed sensing: Performance at different acceleration factors in patients with aortic disease [J].
Pathrose, Ashitha ;
Ma, Liliana ;
Berhane, Haben ;
Scott, Michael B. ;
Chow, Kelvin ;
Forman, Christoph ;
Jin, Ning ;
Serhal, Ali ;
Avery, Ryan ;
Carr, James ;
Markl, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) :2174-2187
[29]  
Rohlffs F, 2015, J CARDIOVASC SURG, V56, P231
[30]   4D flow imaging with MRI [J].
Stankovic, Zoran ;
Allen, Bradley D. ;
Garcia, Julio ;
Jarvis, Kelly B. ;
Markl, Michael .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) :173-192