Biomechanical performance of talon cannulated compression device in pauwels type III fractures: a comparative study

被引:2
作者
Taskent, Hayri Can [1 ]
Alemdarog, Kadir Bahadir [1 ,3 ]
Uslan, Yunus [2 ]
Ercan, Niyazi [1 ]
Demir, Teyfik [2 ]
机构
[1] SBU Ankara Training & Res Hosp, Dept Orthopaed & Traumatol, Ankara, Turkiye
[2] TOBB Univ Econ & Technol, Mech Engn, Ankara, Turkiye
[3] Ankara Egitim & Aras tırma Hastanesi Ulucanl, TR-06340 Ankara, Turkiye
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷 / 11期
关键词
Femoral neck fractures; Pauwels type III; Osteosynthesis; Talon-cannulated compression device; Biomechanical; Torsional stiffness; FEMORAL-NECK FRACTURE; FIXATION METHODS; SCREW; HIP; STABILITY; LOCKING; PLATE;
D O I
10.1016/j.injury.2023.111018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Pauwels Type III fractures are unstable and frequently treated with cannulated screws (CS) or dynamic hip screws (DHS). The newly developed talon-cannulated compression devices (TCCD) have the potential to provide rotational stability, mainly through their talon. The study investigates whether TCCD has mechanical advantages over conventional screws or can be as stable as DHS in a reverse triangle configuration for an unstable femoral neck fracture.Material and methods: After creating a standard Pauwels Type III unstable femoral neck fracture in 36 synthetic femur bones in cortical/hard cancellous bone density, 18 were reserved for dynamic-static tests, and 18 were used for torsional tests. Each group containing 18 synthetic bones was divided into three groups to apply three different fixation materials (CS, DHS, and TCCD), with six models in each group. The displacement amounts after dynamic-static tests were measured using the AutoCAD program according to the reference measurement criteria. During the dynamic tests, a series of photographs were taken. During the static tests, the beginning and post-test photographs were taken. Finally, torsional tests were performed until implant failure occurred in the synthetic femur.Results: In static axial loading tests, TCDD was found to be statistically superior to conventional CS in AL-BL distance (p = 0,014) and CL distance (p = 0,013) measurements, and there was no significant difference between the other groups. There was no significant difference between all groups in dynamic axial compression tests in any points of interest. In torsional tests, TCCD outperformed cannulated screws in stiffness (p = 0,001) and maximum torque (p = 0,001) categories, and they provided statistically significant superiority to DHS in yield torque (p<0,001) category.Conclusions: Biomechanically, TCCD predominates conventional cannulated screws in femoral neck fractures. TCCD also has superior torsional properties than DHS in the yield torque category. Therefore, TCCD could be the implant of choice for unstable femoral neck fractures.
引用
收藏
页数:6
相关论文
共 30 条
[1]  
Ansell R H, 1968, J Biomech, V1, P279, DOI 10.1016/0021-9290(68)90023-7
[2]  
ARICAN G, 2019, Acta Medica Alanya, V3, P261
[3]   Targon® Femoral Neck for femoral-neck fracture fixation: lessons learnt from a series of one hundred and thirty five consecutive cases [J].
Biber, Roland ;
Brem, Matthias ;
Bail, Hermann Josef .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) :595-599
[4]   Use of the talon hip compression screw in intertrochanteric fractures of the hip [J].
Bramlet, DG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) :93-100
[5]   Biomechanical evaluation of a new type of hip compression screw with retractable talons [J].
Bramlet, DG ;
Wheeler, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (09) :618-624
[6]   Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study [J].
Chen, Chao ;
Yu, Li ;
Tang, Xin ;
Liu, Mo-zhen ;
Sun, Li-zhong ;
Liu, Changjian ;
Zhang, Zhen ;
Li, Chang-zhou .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (05) :381-387
[7]  
Chen Zhibing, 2011, Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, V25, P26
[8]  
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[9]   Gaps and opportunities in the management of the young femoral neck fracture [J].
Della Rocca, Gregory J. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (03) :515-518
[10]   Technologies for Young Femoral Neck Fracture Fixation [J].
Duffin, Matthew ;
Pilson, Holly T. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 :S20-S26