A polyaniline/polyvinyl acetate composite film electrode for highly sensitive electrochemical sensing of pH

被引:11
|
作者
Kang, Qi [1 ]
Takehara, Hiroaki [1 ]
Ichiki, Takanori [1 ]
机构
[1] Univ Tokyo, Dept Mat Engn, Tokyo 1138654, Japan
关键词
Polyaniline; Polyvinyl acetate; PH sensing; High sensitivity; Emeraldine; Electrochemical detection; SENSOR; TEMPERATURE; GRAPHENE; NANOSTRUCTURES; PROBE;
D O I
10.1016/j.synthmet.2023.117380
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The electrochemical performances of three types of polyaniline (PANI)-based films developed as pH-sensing electrodes were evaluated and compared. PANI emeraldine base (PANI-EB), PANI emeraldine salt (PANI-ES), and PANI-ES/polyvinyl acetate (PVAc) composite films were spin coated on fluorine-doped tin oxide (FTO) glass substrates to fabricate pH-sensing electrodes. The surface morphology, wetting properties, and electrochemical properties were characterized and compared. Unprotonated PANI-EB films had a regular structure with residual flakes, whereas protonated PANI-ES and PANI-ES/PVAc films exhibited globular and porous structures, respectively. All PANI-based films adhered well to the FTO substrate. Water contact angles indicated the hy-drophobic characteristic of the PANI-EB films and the hydrophilicity of the PANI-ES films, which could affect their stability in buffered solutions of different pH. The PANI-ES/PVAc films exhibited improved stability because of the hydrophobic PVAc. The PANI-ES/PVAc electrodes exhibited a significantly higher pH sensitivity of 100 mV pH-1 than those of the single-component PANI-EB and PANI-ES electrodes (57 and 65 mV pH-1, respectively) in the pH range of 3.0-8.0, which could be attributed to the non-equilibrium protonation/depro-tonation of nitrogen atoms in the PANI structure. Moreover, the PANI-ES/PVAc electrodes also exhibited good reproducibility and selectivity to H+ over certain other ions and molecules (e.g., glucose).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Copper nanoparticles/polyaniline/graphene composite as a highly sensitive electrochemical glucose sensor
    Zheng, Weiran
    Hu, Liangsheng
    Lee, Lawrence Yoon Suk
    Wong, Kwok-Yin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 : 155 - 160
  • [2] Polyaniline/nickel Composite Film Modified Electrode for Sensitive Electrochemical Determination of Ascorbic Acid
    Govindasamy, Mani
    Mani, Veerappan
    Chen, Shen-Ming
    Sathiyan, Anandaraj
    Merlin, Johnson Princy
    Boopathy, Gopal
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12): : 10806 - 10814
  • [3] An Electrochemical pH Sensor Based on the Amino-Functionalized Graphene and Polyaniline Composite Film
    Su, W.
    Xu, J.
    Ding, Xianting
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2016, 15 (08) : 812 - 819
  • [4] Hydrazine chemical sensing by modified electrode based on in situ electrochemically synthesized polyaniline/graphene composite thin film
    Ameen, Sadia
    Akhtar, M. Shaheer
    Shin, Hyung Shik
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 177 - 183
  • [5] Graphene Modified ZnO/Polyaniline Electrode Material for Electrochemical Sensing of Phenol Compounds
    Salim, La Ode Agus
    Yunita, Kurnia Sri
    Irwan, Irwan
    Nakai, Toshiyuki
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2023, 59 (06) : 764 - 771
  • [6] Using of Polyaniline–Polyvinyl Acetate Composite to Remove Mercury from Aqueous Media
    Majid Riahi Samani
    Davood Toghraie
    International Journal of Environmental Research, 2020, 14 : 303 - 310
  • [7] pH effect on the electrochemical redox reaction of disulfide with polyaniline film electrode in organic solution
    Kim, S
    Chung, IJ
    SYNTHETIC METALS, 1998, 96 (03) : 213 - 221
  • [8] Electrochemical Synthesis of Iron Oxide-Polyaniline Composite Thin Film for Supercapacitor Electrode
    Shinde, M. M.
    Sutar, S. V.
    Kunnbhar, J. K.
    Chougale, U. M.
    Fulari, V. J.
    ADVANCED SCIENCE LETTERS, 2015, 21 (08) : 2645 - 2648
  • [9] Using of Polyaniline-Polyvinyl Acetate Composite to Remove Mercury from Aqueous Media
    Samani, Majid Riahi
    Toghraie, Davood
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2020, 14 (03) : 303 - 310
  • [10] Pt electrode modified with β-cyclodextrin/polyaniline for electrochemical sensing of penicillin V
    Djaalab, Elbahi
    Samar, Mohamed Elhadi
    Zougar, Saida
    Kherrat, Rochdi
    SENSOR REVIEW, 2020, 40 (02) : 247 - 254