Optimizing the design of a serpentine microchannel based on particles focusing and separation: A numerical study with experimental validation

被引:22
作者
Ebrahimi, Sina [1 ]
Alishiri, Mojgan [1 ]
Shamloo, Amir [1 ,3 ]
Pishbin, Esmail [2 ]
Hemmati, Parnian [1 ]
Seifi, Saeed [1 ]
Shaygani, Hossein [1 ]
机构
[1] Sharif Univ Technol, Sch Mech Engn, Tehran, Iran
[2] Iranian Res Org Sci & Technol, Biomicrofluid lab, Dept Elect Engn & Informat Technol, Tehran, Iran
[3] Sharif Univ Technol, Sch Mech Engn, Azadi Ave, Tehran, Iran
关键词
Serpentine Microfluidic System; Separation; Focusing; Optimization; Circulating Tumor Cells; FLOW; MICROFLUIDICS; SIMULATION; SYSTEM;
D O I
10.1016/j.sna.2023.114432
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cell-based diagnosis and the introduction of personalized drugs are key factors, motivating researchers to discover an efficacious tool for effective cell isolation. Optimal systems were presented through the finite element method by adjusting the arrangement of hydrodynamic forces within a serpentine micro-channel, which managed to separate different cell lines in addition to their focusing. Considering the parameters of flow, par-ticle, and geometry, two optimal serpentine systems (fixed and variable slope) were presented and the accuracy of the simulation results was verified by their comparison with the experimental findings of the optimized microchannel. The results indicated that the channel heights of-1800 mu m and-2200 mu m are the most suitable choices for particle separation in the range of-7 mu m to-18 mu m (blood cells) for fixed-slope and the last cycle of the variable-slope microchannel, respectively. Both fixed-slope and variable-slope geometries with the vertical channel width of-400 mu m offered a high separation efficiency (about-60 mu m) with a difference of less than-3% in separating red blood cells (RBCs) from circulating tumor cells (CTCs). In addition to separation, the particle focusing efficiency of the microchannels was approximately-98% for low diameter particles (7-21 mu m) and-95% and-93% for-24 mu m and-27 mu m diameter particles, respectively. Through experimental vali-dation, this study presented a reliable optimized structure to improve our ability to separate white blood cells (WBCs) (18 mu m >diameter>12 mu m) and CTCs (27 mu m>diameter>21 mu m) from RBCs, opening new horizons to eliminate at least one of the limitations of the field of diagnosis.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Novel size-based design of spiral microfluidic devices with elliptic configurations and trapezoidal cross-section for ultra-fast isolation of circulating tumor cells
    Akbarnataj, Kazem
    Maleki, Sasan
    Rezaeian, Masoud
    Haki, Mohammad
    Shamloo, Amir
    [J]. TALANTA, 2023, 254
  • [2] Particle deposition and layer formation at the crossflow microfiltration
    Altmann, J
    Ripperger, S
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1997, 124 (01) : 119 - 128
  • [3] Particles Focusing and Separation by a Novel Inertial Microfluidic Device: Divergent Serpentine Microchannel
    Amani, Ali
    Shamloo, Amir
    Vatani, Pouyan
    Ebrahimi, Sina
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (38) : 14324 - 14333
  • [4] ITERATIVE PROCEDURES FOR NONLINEAR INTEGRAL EQUATIONS
    ANDERSON, DG
    [J]. JOURNAL OF THE ACM, 1965, 12 (04) : 547 - &
  • [5] An updated review on particle separation in passive microfluidic devices
    Bayareh, Morteza
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 153
  • [6] Enhanced oil-in-water droplet generation in a T-junction microchannel using water-based nanofluids with shear-thinning behavior: A numerical study
    Besanjideh, Mohsen
    Shamloo, Amir
    Hannani, Siamak Kazemzadeh
    [J]. PHYSICS OF FLUIDS, 2021, 33 (01)
  • [7] Microfluidics for cell separation
    Bhagat, Ali Asgar S.
    Bow, Hansen
    Hou, Han Wei
    Tan, Swee Jin
    Han, Jongyoon
    Lim, Chwee Teck
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (10) : 999 - 1014
  • [8] Inertial microfluidics for sheath-less high-throughput flow cytometry
    Bhagat, Ali Asgar S.
    Kuntaegowdanahalli, Sathyakumar S.
    Kaval, Necati
    Seliskar, Carl J.
    Papautsky, Ian
    [J]. BIOMEDICAL MICRODEVICES, 2010, 12 (02) : 187 - 195
  • [9] Continuous particle separation in spiral microchannels using dean flows and differential migration
    Bhagat, Ali Asgar S.
    Kuntaegowdanahalli, Sathyakumar S.
    Papautsky, Ian
    [J]. LAB ON A CHIP, 2008, 8 (11) : 1906 - 1914
  • [10] INTEGRATION OF STIFF EQUATIONS
    CURTISS, CF
    HIRSCHFELDER, JO
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1952, 38 (03) : 235 - 243