Volumetric and dimensional accuracy assessment of CAD- CAMemanufactured dental prostheses from different materials

被引:27
作者
Pacquet, William [1 ,4 ,5 ]
Tapie, Laurent [2 ]
Mawussi, Bernardin [2 ]
Boitelle, Philippe [3 ]
机构
[1] Univ Lille Nord France, Fac Dent, Oral Rehabil Dept, Paris, France
[2] Univ Sorbonne Paris Nord, Mech Engn Dept, Paris, France
[3] Univ Lille Nord France, Fac Dent, Oral Rehabil Dept, Paris, France
[4] Univ Paris, Res Unit Innovat Dent Mat & Interfaces URB2ieUR 44, F-92120 Montrouge, France
[5] Univ Paris 13, 1 Rue M Arnoux, F-92120 Montrouge, France
关键词
SUBSURFACE DAMAGE; CAD/CAM; RESTORATIONS; CERAMICS; CROWNS; FIT; BIOMATERIALS; MICROLEAKAGE; RESISTANCE; THICKNESS;
D O I
10.1016/j.prosdent.2021.05.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. In computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry, the CAD of the prosthesis represents the clinical prerequisite design to restore the treated tooth. However, how closely the CAM prosthesis shape matches the CAD, particularly in relation to different materials, is unclear. Purpose. The purpose of this in vitro study was to evaluate onlays designed and manufactured with the same CAD-CAM system but manufactured with different materials.Material and methods. A single standard tessellation language (STL) model was used to produce 6 composite resin onlays, 6 leucite glass-ceramic onlays, and 6 lithium disilicate glass-ceramic onlays. The onlays were digitized by using an X-ray microtomographic protocol with a metrological calibration. The CAD model was then compared with the scans of the different onlays. An analysis by region of interest was then carried out to assess the accuracy and reliability of the dimensional accuracy.Results. The composite resin and the lithium disilicate glass-ceramic had the best dimensional accuracy. The leucite glass-ceramic exhibited a lack of trueness linked to consistent overmilling. The composite resin had less peripheral chipping than the glass-ceramics.Conclusions. The composite resin and the lithium disilicate glass-ceramic material exhibited satisfactory dimensional accuracy. Milling the glass-ceramic before crystallization considerably improved dimensional accuracy. (J Prosthet Dent 2023;129:150-9)
引用
收藏
页码:150 / 159
页数:10
相关论文
共 39 条
[1]  
Ahlers M O, 2009, Int J Comput Dent, V12, P309
[2]  
[Anonymous], 1994, Accuracy trueness and precision of measurement methods and results
[3]   Slow crack growth behaviour of hydroxyapatite ceramics [J].
Benaqqa, C ;
Chevalier, J ;
Saädaoui, M ;
Fantozzi, G .
BIOMATERIALS, 2005, 26 (31) :6106-6112
[4]   Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III: Marginal and internal fit [J].
Benic, Goran, I ;
Sailer, Irena ;
Zeltner, Marco ;
Gutermann, Janine N. ;
Ozcan, Mutlu ;
Muhlemann, Sven .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) :426-431
[5]   A systematic review of CAD/CAM fit restoration evaluations [J].
Boitelle, P. ;
Mawussi, B. ;
Tapie, L. ;
Fromentin, O. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (11) :853-874
[6]   Mechanical interactions of cuspal-coverage designs and cement thickness in a cusp-replacing ceramic premolar restoration: a finite element study [J].
Chang, Yen-Hsiang ;
Lin, Wen-Hsueng ;
Kuo, Wen-Chieh ;
Chang, Chia-Yu ;
Lin, Chun-Li .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (04) :367-374
[7]   Machinability of CAD-CAM materials [J].
Chavali, Ramakiran ;
Nejat, Amir H. ;
Lawson, Nathaniel C. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) :194-199
[8]   Abrasive machining of glass-ceramics with a dental handpiece [J].
Dong, X ;
Yin, L ;
Jahanmir, S ;
Ives, LK ;
Rekow, ED .
MACHINING SCIENCE AND TECHNOLOGY, 2000, 4 (02) :209-233
[9]   Fatigue crack propagation path across the dentinoenamel junction complex in human teeth [J].
Dong, XD ;
Ruse, ND .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :103-109
[10]   A quality assurance phantom for the performance evaluation of volumetric micro-CT systems [J].
Du, Louise Y. ;
Umoh, Joseph ;
Nikolov, Hristo N. ;
Pollmann, Steven I. ;
Lee, Ting-Yim ;
Holdsworth, David W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23) :7087-7108