Quantitative Phase Imaging Using Digital Holographic Microscopy to Assess the Degree of Intestinal Inflammation in Patients with Ulcerative Colitis

被引:3
|
作者
Bokemeyer, Arne [1 ]
Buskermolen, Joost [2 ]
Ketelhut, Steffi [3 ]
Tepasse, Phil-Robin [2 ]
Vollenberg, Richard [2 ]
Trebicka, Jonel [2 ]
Schmidt, Hartmut H. [1 ]
Vieth, Michael [4 ]
Bettenworth, Dominik [2 ,5 ]
Kemper, Bjoern [3 ]
机构
[1] Univ Duisburg Essen, Univ Hosp Essen, Dept Gastroenterol Hepatol & Transplant Med, D-45147 Essen, Germany
[2] Univ Hosp Muenster, Dept Med B Gastroenterol Hepatol Endocrinol & Clin, D-48149 Munster, Germany
[3] Univ Munster, Biomed Technol Ctr, D-48149 Munster, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg, Klinikum Bayreuth, Inst Pathol, D-95445 Bayreuth, Germany
[5] CED Schwerpunktpraxis Munster, D-48149 Munster, Germany
关键词
quantitative phase imaging; digital holographic microscopy; inflammatory bowel disease; ulcerative colitis; inflammation; refractive index; histopathology; HISTOLOGICAL ASSESSMENT; DISEASE-ACTIVITY; REMISSION; THERAPY; INDEX;
D O I
10.3390/jcm12124067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ulcerative colitis (UC) is characterized by chronic inflammation of the colorectum. Histological remission has emerged as a potential future treatment goal; however, the histopathological assessment of intestinal inflammation in UC remains challenging with a multitude of available scoring systems and the need for a pathologist with expertise in inflammatory bowel disease (IBD). In previous studies, quantitative phase imaging (QPI) including digital holographic microscopy (DHM) was successfully applied as an objective method for stain-free quantification of the degree of inflammation in tissue sections. Here, we evaluated the application of DHM for the quantitative assessment of histopathological inflammation in patients with UC. In our study, endoscopically obtained colonic and rectal mucosal biopsy samples from 21 patients with UC were analyzed by capturing DHM-based QPI images that were subsequently evaluated using the subepithelial refractive index (RI). The retrieved RI data were correlated with established histological scoring systems including the Nancy index (NI) as well as with endoscopic and clinical findings. As a primary endpoint, we found a significant correlation between the DHM-based retrieved RI and the NI (R-2 = 0.251, p < 0.001). Furthermore, RI values correlated with the Mayo endoscopic subscore (MES; R-2 = 0.176, p < 0.001). An area under the receiver operating characteristics (ROC) curve of 0.820 confirms the subepithelial RI as a reliable parameter to distinguish biopsies with histologically active UC from biopsies without evidence of active disease as determined by conventional histopathological examination. An RI higher than 1.3488 was found to be the most sensitive and specific cut-off value to identify histologically active UC (sensitivity of 84% and specificity of 72%). In conclusion, our data demonstrate DHM to be a reliable tool for the quantitative assessment of mucosal inflammation in patients with UC.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Telecentric phase imaging at extended depth of focus using digital holographic microscopy
    Kumari, Vineeta
    Barak, Neelam
    Sharma, Ajay K.
    Anand, Arun
    Sheoran, Gyanendra
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2024, 87 : 23 - 32
  • [32] Phase and fluorescence imaging by combination of digital holographic microscopy and fluorescence microscopy
    Quan, Xiangyu
    Nitta, Kouichi
    Matoba, Osamu
    Xia, Peng
    Awatsuji, Yasuhiro
    OPTICAL REVIEW, 2015, 22 (02) : 349 - 353
  • [33] Three-dimensional quantitative phase imaging of blood coagulation structures by optical projection tomography in flow cytometry using digital holographic microscopy
    Funamizu, Hideki
    Aizu, Yoshihisa
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (03)
  • [34] Online quantitative phase imaging of vascular endothelial cells under fluid shear stress utilizing digital holographic microscopy
    Odenthal-Schnittler, Maria
    Schnittler, Hans Joachim
    Kemper, Bjoern
    QUANTITATIVE PHASE IMAGING II, 2016, 9718
  • [35] Quantitative phase imaging with scanning holographic microscopy: an experimental assesment
    Guy Indebetouw
    Yoshitaka Tada
    John Leacock
    BioMedical Engineering OnLine, 5
  • [36] Quantitative phase imaging of cells in a flow cytometry arrangement utilizing Michelson interferometer-based off-axis digital holographic microscopy
    Min, Junwei
    Yao, Baoli
    Trendafilova, Veselina
    Ketelhut, Steffi
    Kastl, Lena
    Greve, Burkhard
    Kemper, Bjoern
    JOURNAL OF BIOPHOTONICS, 2019, 12 (09)
  • [37] Automatic Phase Aberration Compensation and Imaging of Digital Holographic Microscopy
    Wang Xing
    Ma Hong-Wei
    Wang Dou-Dou
    Dong Ming
    Zhang Yi-Shu
    Wang Hao-Tian
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [38] Multimodal digital holographic microscopy for simultaneous phase and fluorescence imaging
    Quan, Xiangyu
    Osamu, Matoba
    Awatsuji, Yasuhiro
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [39] New Approaches for the analysis of confluent cell layers with quantitative phase digital holographic microscopy
    Pohl, L.
    Kaiser, M.
    Ketelhut, S.
    Pereira, S.
    Goycoolea, F.
    Kemper, Bjoern
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XXIII, 2016, 9713
  • [40] Modular digital holographic microscopy system for marker free quantitative phase contrast imaging of living cells
    Kemper, Bjoern
    Carl, Daniel
    Hoeink, Alexander
    von Bally, Gert
    Bredebusch, Ilona
    Schnekenburger, Juergen
    BIOPHOTONICS AND NEW THERAPY FRONTIERS, 2006, 6191