Development of a real-time monitoring and detection indoor air quality system for intensive care unit and emergency department

被引:14
|
作者
Baqer, Noor S. [1 ]
Mohammed, Hussein A. [2 ]
Albahri, A. S. [1 ]
机构
[1] Informat Inst Postgrad Studies IIPS, Iraqi Commiss Comp & Informat ICCI, Baghdad 10001, Iraq
[2] Univ Informat Technol & Commun UOITC, Baghdad 10001, Iraq
关键词
Indoor air quality; Sensors; Internet of things; Intensive care unit; Emergency department; Monitoring and detection;
D O I
10.22514/sv.2022.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To develop an Indoor Air Quality (IAQ) monitoring and detecting system based on a new Internet of Thing (IoT) sensory technology device that incorporated nine recommended indoor pollutants by the academic literature and reliable organizations, such as World Health Organization (WHO), Environmental Protection Agency (EPA), and International Organization for Standardization (ISO). The pollutants include Carbon Monoxide (CO), Carbon Dioxide (CO2), Nitrogen Dioxide (NO2), Ozone (O-3), Formaldehyde (HCHO), Volatile Organic Compounds (VOC), Particulate Matter 2.5 (PM2.5) as well as air humidity and temperature that are used to assess the variety of indoor pollutants and provide a new IAQ pollutants dataset. Besides, the newly developed system provides real-time air quality monitoring, reports the pollutants' data to a cloud platform (i.e., ThingSpeak), and can trigger early warnings as a service when abnormalities occurred in the air quality index. The system was tested to ensure its conformance to the recommended pollutants by collaborating with surgeons and specializing in IAQ in a hospital surgical intensive care unit (SICU), emergency department (ED), and in the women's ward, which accommodate patients who are either newly born mothers (in case they need that) or who have had an operation, as well as pregnant patients who need to stay in the hospital to be under the supervision of medical care. Nine pollutants were identified and collected the pollutants dataset and their thresholds that affect the air quality within the hospital facilities and services (SICU, ED) to be used for assessing the effectiveness of the amount, concentration, and diversity of the pollutants. In the SICU, the concentrations of some pollutants were high in the beginning due to the residues of the previous surgery and because of the frequent use of sterilizers to clean and prepare the surgery room. Then, the concentrations of pollutants were moderate, but minutes after the start of the surgical, an increase in CO2 and formaldehyde was observed, which exceeds the threshold limit because of the use of anesthetic gas and sterilization. In the women's ward, was all concentrations generally moderate except for particles matter PM2.5, and the same context with the 3rd installed location in the pharmacy of ED, most concentrations were moderate, except formaldehyde which exceeded the threshold. "CO" was the highest positive correlated and strongly correlated to "NO2" and that was expected because CO influences the oxidation of NO to NO2. On the contrary, the "CO" had the highest negative correlation with "VOC", and the "NO2" had the highest negative correlation with "VOC", chemistry is part of the responsibility for the weak correlation observed between the pollutants.
引用
收藏
页码:77 / 92
页数:16
相关论文
共 50 条
  • [21] Improving Turnaround Time for Critical Care and Emergency Department Testing Using a Visual Real-Time Dynamic Monitoring System
    Scinto, Leonard
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A055 - A055
  • [22] REAL-TIME ULTRASONOGRAPHY IN THE INTENSIVE-CARE UNIT
    HABSCHEID, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1989, 114 (51-52) : 1989 - 1995
  • [23] A Power Quality Monitoring System for Real-Time Fault Detection
    Yingkayun, Krisda
    Premrudeepreechacharn, Suttichai
    Oranpiroj, Kosol
    ISIE: 2009 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, 2009, : 1829 - +
  • [24] Real-time Continuous Glucose Monitoring in the Intensive Care Unit: The Fifth Vital Sign
    Patham, Bhargavi
    Kansara, Abhishek
    Sadhu, Archana R.
    DIABETES CARE, 2024, 47 (06) : 924 - 926
  • [25] Design and implementation of a real-time clinical alerting system for intensive care unit
    Chen, HT
    Ma, WC
    Liou, DM
    AMIA 2002 SYMPOSIUM, PROCEEDINGS: BIOMEDICAL INFORMATICS: ONE DISCIPLINE, 2002, : 131 - 135
  • [26] Analyzing the Impact of Occupancy Patterns on Indoor Air Quality in University Classrooms Using a Real-Time Monitoring System
    Sulitiyanti, Ratna
    Komarudin, Muhamad
    Setyawan, F. X. Arinto
    Septama, Hery Dian
    Yulianti, Titin
    Ammar, M. Farid
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (10) : 485 - 492
  • [27] Real-Time Indoor Air Quality Monitoring and Purification System using Sensor Data and Machine Learning Technique
    Poulo, Annmaria
    Manoj, Aswathy
    Muhsina, V. A. Fathima
    Titus, E. Gaea
    Neema, M.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE COMPUTING AND SMART SYSTEMS, ICSCSS 2024, 2024, : 1271 - 1279
  • [28] Development of Multi-Item Air Quality Monitoring System Based on Real-Time Data
    Park, Beomseok
    Kim, Sebin
    Park, Seoryeong
    Kim, Minji
    Kim, Tae Yoo
    Park, Hanbai
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [29] Review of bispectral index monitoring in the emergency department and pediatric intensive care unit
    Dominguez, Troy E.
    Helfaer, Mark A.
    PEDIATRIC EMERGENCY CARE, 2006, 22 (12) : 815 - 821
  • [30] An extension of Real-time Traffic Monitoring System with Air Quality Module
    Brzozowski, K.
    Konior, A.
    Maczynski, A.
    Rygula, A.
    PROCEEDINGS OF THE 20TH INTERNATIONAL SCIENTIFIC CONFERENCE TRANSPORT MEANS 2016, 2016, : 75 - 79