The IMSCal approach to determine collision cross section of multiply charged anions in traveling wave ion mobility spectrometry

被引:3
作者
Sergent, Isaure [1 ]
Adjieufack, Abel Idrice [1 ]
Gaudel-Siri, Anouk [1 ]
Siri, Didier [1 ]
Charles, Laurence [1 ,2 ]
机构
[1] Aix Marseille Univ, CNRS, Inst Chim Radicalaire, Marseille, France
[2] Marseille Univ, Inst Rad Chem, CNRS, UMR 7273, F-13397 Marseille 20, France
关键词
Traveling wave ion mobility spectrometry; Collision cross section; Polyanions; Calibration; MASS-SPECTROMETRY; PROTEIN; PEPTIDE; COMPLEXES;
D O I
10.1016/j.ijms.2023.117112
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The need for appropriate standards to calibrate ion arrival times in traveling wave ion mobility (TWIM) remains an issue for collision cross section (CCS) measurements, particularly in the case of multiply charged anions due to the scarcity of calibrants in the negative ion mode. In order to circumvent constraints raised for standards in the conventional power law calibration, the new approach recently implemented in the IMSCal software (Anal. Chem. 93 (2021) 3542-3550) has been evaluated here to derive CCS of multiply charged anions measured by TWIM. The mathematical model developed in IMSCal to describe ion motion in the TWIM cell was trained with different combinations of phosphoric acid clusters and deprotonated polyalanine standards and performance of so-obtained calibrations was evaluated for multiply deprotonated oligothymidine 10mers used as control analytes. Although optimal composition of the calibrant set could not be fully rationalized, one mandatory condition for best CCS accuracy is to include standards of different charge states to properly model the effects of radial distribution of ions in the TWIM cell. Further improvement of calibration robustness requires that one of these charge states equals that of the analytes to account for the effects of velocity relaxation also incorporated in the IMSCal model. Doing so, experimental CCS values could be readily obtained with relative error below & PLUSMN;5% for anions of charge state up to 6-.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry
    Dodds, James N.
    May, Jody C.
    McLean, John A.
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12176 - 12184
  • [42] Traveling Wave Ion Mobility Mass Spectrometry Study of Low Generation Polyamidoamine Dendrimers
    Maire, Florian
    Coadou, Gael
    Cravello, Laetitia
    Lange, Catherine M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (02) : 238 - 248
  • [43] A structural examination and collision cross section database for over 500 metabolites and xenobiotics using drift tube ion mobility spectrometry
    Zheng, Xueyun
    Aly, Noor A.
    Zhou, Yuxuan
    Dupuis, Kevin T.
    Bilbao, Aivett
    Paurus, Vanessa L.
    Orton, Daniel J.
    Wilson, Ryan
    Payne, Samuel H.
    Smith, Richard D.
    Baker, Erin S.
    CHEMICAL SCIENCE, 2017, 8 (11) : 7724 - 7736
  • [44] Collision cross-section analysis of self-assembled metallomacrocycle isomers and isobars via ion mobility mass spectrometry
    Endres, Kevin J.
    Barthelmes, Kevin
    Winter, Andreas
    Antolovich, Robert
    Schubert, Ulrich S.
    Wesdemiotis, Chrys
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
  • [45] A comparison of collision cross section values obtained via travelling wave ion mobility-mass spectrometry and ultra high performance liquid chromatography-ion mobility-mass spectrometry: Application to the characterisation of metabolites in rat urine
    Nye, Leanne C.
    Williams, Jonathan P.
    Munjoma, Nyasha C.
    Letertre, Marine P. M.
    Coen, Muireann
    Bouwmeester, Robbin
    Martens, Lennart
    Swann, Jonathan R.
    Nicholson, Jeremy K.
    Plumb, Robert S.
    McCullagh, Michael
    Gethings, Lee A.
    Lai, Steven
    Langridge, James, I
    Vissers, Johannes P. C.
    Wilson, Ian D.
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 386 - 396
  • [46] Protein Structural Studies by Traveling Wave Ion Mobility Spectrometry: A Critical Look at Electrospray Sources and Calibration Issues
    Sun, Yu
    Vahidi, Siavash
    Sowole, Modupeola A.
    Konermann, Lars
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (01) : 31 - 40
  • [47] Effects of Select Anions from the Hofmeister Series on the Gas-Phase Conformations of Protein Ions Measured with Traveling-Wave Ion Mobility Spectrometry/Mass Spectrometry
    Merenbloom, Samuel I.
    Flick, Tawnya G.
    Daly, Michael P.
    Williams, Evan R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (11) : 1978 - 1990
  • [48] Factors Contributing to the Collision Cross Section of Polyatomic Ions in the Kilodalton to Gigadalton Range: Application to Ion Mobility Measurements
    Wyttenbach, Thomas
    Bleiholder, Christian
    Bowers, Michael T.
    ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2191 - 2199
  • [49] Collision cross section prediction of deprotonated phenolics in a travelling-wave ion mobility spectrometer using molecular descriptors and chemometrics
    Gonzales, Gerard Bryan
    Smagghe, Guy
    Coelus, Sofie
    Adriaenssens, Dieter
    De Winter, Karel
    Desmet, Tom
    Raes, Katleen
    Van Camp, John
    ANALYTICA CHIMICA ACTA, 2016, 924 : 68 - 76
  • [50] Diversity in Gold Finger Structure Elucidated by Traveling-Wave Ion Mobility Mass Spectrometry
    Du, Zhifeng
    de Paiva, Raphael E. F.
    Nelson, Kristina
    Farrell, Nicholas P.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (16) : 4464 - 4467