Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife

被引:0
作者
Li, Jun [1 ]
Kong, Xianghui [2 ,3 ]
Cheng, Cheng [1 ]
Wang, Gong [1 ]
Zhuang, Hongqing [1 ]
Yang, Ruijie [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] Soochow Univ, Sch Radiat Med & Protect, Suzhou, Peoples R China
[3] Collaborat Innovat Ctr Radiol Med Jiangsu Higher E, Suzhou, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
lumbosacral spinal tumor; supine position; prone position; xsight spine prone tracking; CyberKnife; RADIOTHERAPY; CANCER; MOTION;
D O I
10.3389/fonc.2023.959447
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveThe aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. MethodsEighteen patients with lumbosacral spinal tumors were selected. CT simulation was performed in the supine position (fixed with a vacuum cushion) and prone position (fixed with a thermoplastic mask and prone plate), respectively. The plans in the supine and prone positions were designed using the xsight spine tracking (XST) and xsight spine prone tracking (XSPT) modalities, respectively. The dose-volume histogram (DVH) parameters, namely, V-100%, D-95%, D-mean, conformity index (CI), and heterogeneity index (HI) in planning target volume (PTV), as well as D-max, D-0.1cc, D-1cc, and D-5cc in the cauda equina and bowel were recorded. The supine plans were simulation plans and were not used for treatment, which were only used to record the alignment errors. The spinal tracking correction errors (alignment error) and correlation errors of the synchrony respiratory model in the prone position were recorded during the treatment. After treatment, the simulation plan of the supine position was implemented and the spinal tracking correction errors were recorded. The parameters of correction error and DVH parameters for the two positions were analyzed using the paired t-test to compare the difference in positioning accuracy and dose distribution. In addition, the correlation errors of the synchrony respiratory model in the prone position were analyzed to evaluate the prediction accuracy of the synchrony model. ResultsFor patient setup, the correction error of the supine position in interior/posterior was (0.18 +/- 0.16) mm and the prone position was (0.31 +/- 0.26) mm (P< 0.05). The correction error of the supine position in inferior/superior was (0.27 +/- 0.24) mm, and the prone position was (0.5 +/- 0.4) mm (P< 0.05). The average correlation errors of the synchrony model for left/right, inferior/superior, and anterior/posterior in the prone position were (0.21 +/- 0.11) mm, (0.41 +/- 0.38) mm, and (0.68 +/- 0.42) mm, respectively. For the dose distribution, compared with prone plans, the average CI in supine plans was increased by 4.5% (P< 0.05). There was no significant difference in HI, PTV V-100%,V- D-95%, and D-mean between the prone and supine plans. Compared with supine plans, average D-1cc and D-5cc for the cauda equina was significantly decreased by 4.7 and 15.3% in the prone plan (P< 0.05). For the bowel, average D-max, D-0.1cc, D-1cc, and D-5cc were reduced by 8.0, 7.7, 5.2, and 26.6% in prone plans (P< 0.05) compared with supine plans. ConclusionCompared with the supine setup, the prone setup combined with XSPT modality for the lumbosacral spinal stereotactic body radiosurgery can spare the bowel and cauda equina of the middle and low dose irradiation, and decrease the number of beams and monitor units.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of Intrafractional Motion in Head and Neck Cancer Between Two Immobilization Methods During Stereotactic Ablative Radiation Therapy by CyberKnife
    Kang, Chen-Lin
    Lee, Tsair-Fwu
    Chan, Shan-Ho
    Liu, Shyh-Chang
    Wang, Jui-Chu
    Tsai, Cheng-Hsiang
    Liao, Kuan-Cho
    Fang, Fu-Min
    Chang, Liyun
    Huang, Chun-Chieh
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 13599 - 13606
  • [42] Stereotactic body radiotherapy for spinal oligometastases: a review on patient selection and the optimal methodology
    Kei Ito
    Yujiro Nakajima
    Syuzo Ikuta
    Japanese Journal of Radiology, 2022, 40 : 1017 - 1023
  • [43] Stereotactic body radiotherapy for spinal oligometastases: a review on patient selection and the optimal methodology
    Ito, Kei
    Nakajima, Yujiro
    Ikuta, Syuzo
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (10) : 1017 - 1023
  • [44] A Dosimetric Comparison Between the Supine and Prone Positions for Three-Field Intact Breast Radiotherapy
    Gielda, Benjamin T.
    Strauss, Jonathan B.
    Marsh, James C.
    Turian, Julius V.
    Griem, Katherine L.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2011, 34 (03): : 223 - 230
  • [45] Clinical result of stereotactic radiosurgery for spinal metastasis from hepatocellular carcinoma: comparison with conventional radiation therapy
    Chang, Ung-Kyu
    Kim, Mi-Sook
    Han, Chul Ju
    Lee, Dong Han
    JOURNAL OF NEURO-ONCOLOGY, 2014, 119 (01) : 141 - 148
  • [46] Patient outcomes after vestibular schwannoma management: A prospective comparison of microsurgical resection and stereotactic radiosurgery
    Pollock, Bruce E.
    Driscoll, Colin L. W.
    Foote, Robert L.
    Link, Michael J.
    Gorman, Deborah A.
    Bauch, Christopher D.
    Mandrekar, Jayawant N.
    Krecke, Karl N.
    Johnson, Craig H.
    NEUROSURGERY, 2006, 59 (01) : 77 - 83
  • [47] Multi-institutional investigation into the robustness of intra-cranial multi-target stereotactic radiosurgery plans to patient setup errors
    May, Lauren
    Barnes, Micah
    Hardcastle, Nicholas
    Hernandez, Victor
    Saez, Jordi
    Rosenfeld, Anatoly
    Poder, Joel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [48] Accuracy evaluation of real-time body surface imaging guided system in spinal stereotactic radiosurgery: a phantom study
    Park, Jeong-Mee
    Lee, Haenghwa
    Sohn, Moon-Jun
    Kim, Kwang Hyeon
    Koo, Hae-Won
    Yoon, Sang-Won
    Moon, Chi-Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (01) : 68 - 75
  • [49] A treatment planning comparison between a novel rotating gamma system and robotic linear accelerator based intracranial stereotactic radiosurgery/radiotherapy
    Fareed, Muhammad M.
    Eldib, Ahmed
    Weiss, Stephanie E.
    Hayes, Shelly B.
    Li, Jinsheng
    Ma, Charlie C-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
  • [50] LOCAL SETUP REPRODUCIBILITY OF THE SPINAL COLUMN WHEN USING INTENSITY-MODULATED RADIATION THERAPY FOR CRANIOSPINAL IRRADIATION WITH PATIENT IN SUPINE POSITION
    Stoiber, Eva Maria
    Giske, Kristina
    Schubert, Kai
    Sterzing, Florian
    Habl, Gregor
    Uhl, Matthias
    Herfarth, Klaus
    Bendl, Rolf
    Debus, Juergen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1552 - 1559