Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife

被引:0
作者
Li, Jun [1 ]
Kong, Xianghui [2 ,3 ]
Cheng, Cheng [1 ]
Wang, Gong [1 ]
Zhuang, Hongqing [1 ]
Yang, Ruijie [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] Soochow Univ, Sch Radiat Med & Protect, Suzhou, Peoples R China
[3] Collaborat Innovat Ctr Radiol Med Jiangsu Higher E, Suzhou, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
lumbosacral spinal tumor; supine position; prone position; xsight spine prone tracking; CyberKnife; RADIOTHERAPY; CANCER; MOTION;
D O I
10.3389/fonc.2023.959447
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveThe aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. MethodsEighteen patients with lumbosacral spinal tumors were selected. CT simulation was performed in the supine position (fixed with a vacuum cushion) and prone position (fixed with a thermoplastic mask and prone plate), respectively. The plans in the supine and prone positions were designed using the xsight spine tracking (XST) and xsight spine prone tracking (XSPT) modalities, respectively. The dose-volume histogram (DVH) parameters, namely, V-100%, D-95%, D-mean, conformity index (CI), and heterogeneity index (HI) in planning target volume (PTV), as well as D-max, D-0.1cc, D-1cc, and D-5cc in the cauda equina and bowel were recorded. The supine plans were simulation plans and were not used for treatment, which were only used to record the alignment errors. The spinal tracking correction errors (alignment error) and correlation errors of the synchrony respiratory model in the prone position were recorded during the treatment. After treatment, the simulation plan of the supine position was implemented and the spinal tracking correction errors were recorded. The parameters of correction error and DVH parameters for the two positions were analyzed using the paired t-test to compare the difference in positioning accuracy and dose distribution. In addition, the correlation errors of the synchrony respiratory model in the prone position were analyzed to evaluate the prediction accuracy of the synchrony model. ResultsFor patient setup, the correction error of the supine position in interior/posterior was (0.18 +/- 0.16) mm and the prone position was (0.31 +/- 0.26) mm (P< 0.05). The correction error of the supine position in inferior/superior was (0.27 +/- 0.24) mm, and the prone position was (0.5 +/- 0.4) mm (P< 0.05). The average correlation errors of the synchrony model for left/right, inferior/superior, and anterior/posterior in the prone position were (0.21 +/- 0.11) mm, (0.41 +/- 0.38) mm, and (0.68 +/- 0.42) mm, respectively. For the dose distribution, compared with prone plans, the average CI in supine plans was increased by 4.5% (P< 0.05). There was no significant difference in HI, PTV V-100%,V- D-95%, and D-mean between the prone and supine plans. Compared with supine plans, average D-1cc and D-5cc for the cauda equina was significantly decreased by 4.7 and 15.3% in the prone plan (P< 0.05). For the bowel, average D-max, D-0.1cc, D-1cc, and D-5cc were reduced by 8.0, 7.7, 5.2, and 26.6% in prone plans (P< 0.05) compared with supine plans. ConclusionCompared with the supine setup, the prone setup combined with XSPT modality for the lumbosacral spinal stereotactic body radiosurgery can spare the bowel and cauda equina of the middle and low dose irradiation, and decrease the number of beams and monitor units.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Lung and 'end organ' injury due to mechanical ventilation in animals: comparison between the prone and supine positions
    George Nakos
    Anna Batistatou
    Eftychia Galiatsou
    Eleonora Konstanti
    Vassilios Koulouras
    Panayotis Kanavaros
    Apostolos Doulis
    Athanassios Kitsakos
    Angeliki Karachaliou
    Marilena E Lekka
    Maria Bai
    Critical Care, 10
  • [32] Full automation of spinal stereotactic radiosurgery and stereotactic body radiation therapy treatment planning using Varian Eclipse scripting
    Teruel, Jose R.
    Malin, Martha
    Liu, Elisa K.
    McCarthy, Allison
    Hu, Kenneth
    Cooper, Bejamin T.
    Sulman, Erik P.
    Silverman, Joshua S.
    Barbee, David
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (10): : 122 - 131
  • [33] Stereotactic Body Radiation Therapy for Thoracic Cancers: Recommendations for Patient Selection, Setup and Therapy
    Timmerman, Robert
    Heinzerling, John
    Abdulrahman, Ramzi
    Choy, Hak
    Meyer, John L.
    IMRT IGRT SBRT- ADVANCES IN THE TREATMENT PLANNING AND DELIVERY OF RADIOTHERAPY, 2011, 43 : 395 - 411
  • [34] Comparison of the Effect of Body Position, Prone or Supine, on the Result of Extracorpreal Shock Wave Lithotripsy in Patients with Stones in the Proximal Ureter
    Zomorrodi, Afshar
    Elahian, Amirreza
    Ghorbani, Nematollah
    Tavoosi, Anahita
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2007, 18 (02) : 200 - 205
  • [35] Stereotactic body radiotherapy using a hydrogel spacer for localized prostate cancer: A dosimetric comparison between tomotherapy with the newly-developed tumor-tracking system and cyberknife
    Manabe, Yoshihiko
    Hashimoto, Seiji
    Mukouyama, Hideki
    Shibamoto, Yuta
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 66 - 72
  • [36] COMPARISON BETWEEN INFRARED OPTICAL AND STEREOSCOPIC X-RAY TECHNOLOGIES FOR PATIENT SETUP IN IMAGE GUIDED STEREOTACTIC RADIOTHERAPY
    Tagaste, Barbara
    Riboldi, Marco
    Spadea, Maria F.
    Bellante, Simone
    Baroni, Guido
    Cambria, Raffaella
    Garibaldi, Cristina
    Ciocca, Mario
    Catalano, Gianpiero
    Alterio, Daniela
    Orecchia, Roberto
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1706 - 1714
  • [37] Impact of use of optical surface imaging on initial patient setup for stereotactic body radiotherapy treatments
    Leong, Brian
    Padilla, Laura
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 149 - 158
  • [38] Treatment plan comparison between stereotactic body radiation therapy techniques for prostate cancer: Non-isocentric CyberKnife versus isocentric RapidArc
    Lin, Yu-Wei
    Lin, Kuei-Hua
    Ho, Hsiu-Wen
    Lin, Hsiu-Man
    Lin, Li-Ching
    Lee, Steve P.
    Chui, Chen-Shou
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 654 - 661
  • [39] Enteral feeding in the critically ill: comparison between the supine and prone positions: a prospective crossover study in mechanically ventilated patients
    Peter HJ van der Voort
    Durk F Zandstra
    Critical Care, 5
  • [40] Enteral feeding in the critically ill: comparison between the supine and prone positions - A prospective crossover study in mechanically ventilated patients
    van der Voort, PHJ
    Zandstra, DF
    CRITICAL CARE, 2001, 5 (04): : 216 - 220