Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife

被引:0
作者
Li, Jun [1 ]
Kong, Xianghui [2 ,3 ]
Cheng, Cheng [1 ]
Wang, Gong [1 ]
Zhuang, Hongqing [1 ]
Yang, Ruijie [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] Soochow Univ, Sch Radiat Med & Protect, Suzhou, Peoples R China
[3] Collaborat Innovat Ctr Radiol Med Jiangsu Higher E, Suzhou, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
lumbosacral spinal tumor; supine position; prone position; xsight spine prone tracking; CyberKnife; RADIOTHERAPY; CANCER; MOTION;
D O I
10.3389/fonc.2023.959447
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveThe aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. MethodsEighteen patients with lumbosacral spinal tumors were selected. CT simulation was performed in the supine position (fixed with a vacuum cushion) and prone position (fixed with a thermoplastic mask and prone plate), respectively. The plans in the supine and prone positions were designed using the xsight spine tracking (XST) and xsight spine prone tracking (XSPT) modalities, respectively. The dose-volume histogram (DVH) parameters, namely, V-100%, D-95%, D-mean, conformity index (CI), and heterogeneity index (HI) in planning target volume (PTV), as well as D-max, D-0.1cc, D-1cc, and D-5cc in the cauda equina and bowel were recorded. The supine plans were simulation plans and were not used for treatment, which were only used to record the alignment errors. The spinal tracking correction errors (alignment error) and correlation errors of the synchrony respiratory model in the prone position were recorded during the treatment. After treatment, the simulation plan of the supine position was implemented and the spinal tracking correction errors were recorded. The parameters of correction error and DVH parameters for the two positions were analyzed using the paired t-test to compare the difference in positioning accuracy and dose distribution. In addition, the correlation errors of the synchrony respiratory model in the prone position were analyzed to evaluate the prediction accuracy of the synchrony model. ResultsFor patient setup, the correction error of the supine position in interior/posterior was (0.18 +/- 0.16) mm and the prone position was (0.31 +/- 0.26) mm (P< 0.05). The correction error of the supine position in inferior/superior was (0.27 +/- 0.24) mm, and the prone position was (0.5 +/- 0.4) mm (P< 0.05). The average correlation errors of the synchrony model for left/right, inferior/superior, and anterior/posterior in the prone position were (0.21 +/- 0.11) mm, (0.41 +/- 0.38) mm, and (0.68 +/- 0.42) mm, respectively. For the dose distribution, compared with prone plans, the average CI in supine plans was increased by 4.5% (P< 0.05). There was no significant difference in HI, PTV V-100%,V- D-95%, and D-mean between the prone and supine plans. Compared with supine plans, average D-1cc and D-5cc for the cauda equina was significantly decreased by 4.7 and 15.3% in the prone plan (P< 0.05). For the bowel, average D-max, D-0.1cc, D-1cc, and D-5cc were reduced by 8.0, 7.7, 5.2, and 26.6% in prone plans (P< 0.05) compared with supine plans. ConclusionCompared with the supine setup, the prone setup combined with XSPT modality for the lumbosacral spinal stereotactic body radiosurgery can spare the bowel and cauda equina of the middle and low dose irradiation, and decrease the number of beams and monitor units.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of the dose to lung volume between supine and prone position during treatment planning
    Yu Li
    Huijun Xu
    Sujing Zhang
    Xiaoliang Liu
    Oncology and Translational Medicine, 2015, 1 (06) : 271 - 274
  • [22] Analytical setup margin for spinal stereotactic body radiotherapy based on measured errors
    Copeland, Audrey
    Barron, Addie
    Fontenot, Jonas
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [23] Dosimetric Comparison between the HyperArc and Conventional VMAT in Cervical Spine Stereotactic Radiosurgery
    Park, Jeehoon
    Park, Byungdo
    Kim, Jeongho
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (18)
  • [24] Effect of changing patient position from supine to prone on the accuracy of a Brown-Roberts-Wells stereotactic head frame system
    Rohlfing, T
    Maurer, CR
    Dean, D
    Maciunas, RJ
    NEUROSURGERY, 2003, 52 (03) : 610 - 617
  • [25] Dosimetric and radiobiological comparison of Cyberknife and Tomotherapy in stereotactic body radiotherapy for localized prostate cancer
    Chen, Chun-You
    Lee, Liang-Ming
    Yu, Hsiao-Wei
    Lee, Steve P.
    Lee, Hsin-Lun
    Lin, Yung-Wei
    Wen, Yu-Ching
    Chen, Yi-Ju
    Chen, Chiu-Ping
    Tsai, Jo-Ting
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (03) : 465 - 477
  • [26] Comparison of Whole versus Partial Vertebral Body Stereotactic Body Radiation Therapy for Spinal Metastases
    Patel, Veeral B.
    Wegner, Rodney E.
    Heron, Dwight E.
    Flickinger, John C.
    Gerszten, Peter
    Burton, Steve A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (02) : 105 - 115
  • [27] Radiosurgery Society Case-Based Guide to Stereotactic Body Radiation Therapy for Challenging Cases of Spinal Metastases
    Aziz, Khaled
    Koffler, Daniel
    Vassantachart, April
    Rattani, Abbas
    Ankrah, Nii-Kwanchie
    Gogineni, Emile
    Andraos, Therese Y.
    Sahgal, Arjun
    Vellayappan, Balamurugan
    Dunne, Emma M.
    Siva, Shankar
    Moraes, Fabio Y.
    Guckenberger, Matthias
    Lubelski, Daniel
    Chao, Samuel
    Combs, Stephanie
    Chang, Eric
    Amin, Anubhav G.
    Foote, Matthew
    Gibbs, Iris
    Kim, Minsun
    Palmer, Joshua
    Lo, Simon
    Redmond, Kristin J.
    PRACTICAL RADIATION ONCOLOGY, 2025, 15 (01) : 54 - 68
  • [28] Comparison of Skull Motions in Six Degrees of Freedom Between Two Head Supports During Frameless Radiosurgery by CyberKnife
    Kang, Chen-Lin
    Liu, Shyh-Chang
    Wang, Jui-Chu
    Liao, Kuan-Cho
    Huang, Yu-Jie
    Fang, Fu-Min
    Liao, Tsung-I
    Juan, Kuo-Jung
    Huang, Chun-Chieh
    FRONTIERS IN ONCOLOGY, 2018, 8
  • [29] Multiple Brain Metastases Radiosurgery with CyberKnife Device: Dosimetric Comparison between Fixed/Iris and Multileaf Collimator Plans
    Ianiro, Anna
    Infusino, Erminia
    D'Andrea, Marco
    Marucci, Laura
    Farneti, Alessia
    Sperati, Francesca
    Cassano, Bartolomeo
    Ungania, Sara
    Soriani, Antonella
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 120 - 128
  • [30] Comparison of setup accuracy and efficiency between the Klarity system and BodyFIX system for spine stereotactic body radiation therapy
    Quan, Enzhuo
    Krafft, Shane P.
    Briere, Tina M.
    Vaccarelli, Marissa J.
    Ghia, Amol J.
    Bishop, Andrew J.
    Yeboa, Debra N.
    Swanson, Todd A.
    Han, Eun Young
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):