Thermal analysis of high-temperature proton exchange membrane fuel cell integrated compression-assisted absorption heat pump system

被引:9
作者
Liang, Yu [1 ]
Zhang, Xiao [1 ]
Cai, Liang [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
High-temperature proton exchange membrane; fuel cell; Compression-assisted absorption heat pump; Waste heat recovery; Parametric study; DMETEG; R134a; R1234YF/IONIC LIQUID; PERFORMANCE ANALYSIS; HYBRID SYSTEM; OPTIMIZATION; ENERGY; PEMFC; MODEL; POWER; GAX;
D O I
10.1016/j.ijrefrig.2022.09.035
中图分类号
O414.1 [热力学];
学科分类号
摘要
A combined distributed energy system with integrated high-temperature proton exchange membrane fuel cell (HT-PEMFC) and compression-assisted absorption heat pump (CAHP) is proposed. The HT-PEMFC has the advantage of high efficiency in clean power generation, but also produces abundant waste heat. To achieve waste heat recovery, CAHP with dimethyl ether triethylene glycol (DMETEG)/R134a as working fluid is applied to convert waste heat into cooling/heating capacity. The mathematical model of the combined distributed energy system is established, and the energy conservation of the system in the basic design condition is verified. The effects of five system parameters on the energy output and efficiency of the system are analyzed, and the optimization strategy for the system design is proposed. In the basic design condition, combined distributed energy system yields a heating capacity of 7.8898 kW in heating mode and a cooling capacity of 2.3773 kW in cooling mode, while consuming 9.96% and 7.51% of HT-PEMFC output power respectively. By contrast, sole HTPEMFC has an only electrical power output of 2.333 kW. An appropriate increase of the compression ratio can improve the exergy efficiency and the performance coefficient of the CAHP, and enlarge the operating temperature range. The outlet working fluid temperatures of each component in the heat pump have different effects on the system performance in heating/cooling mode. The results can provide a reference for further development of such distributed energy system.
引用
收藏
页码:91 / 105
页数:15
相关论文
共 46 条
[11]   Performance assessment of a combined system consisting of a high-temperature polymer electrolyte membrane fuel cell and a thermoelectric generator [J].
Guo, Xinru ;
Zhang, Houcheng ;
Yuan, Jinliang ;
Wang, Jiatang ;
Zhao, Jiapei ;
Wang, Fu ;
Miao, He ;
Hou, Shujin .
ENERGY, 2019, 179 :762-770
[12]   Performance evaluation of an integrated high-temperature proton exchange membrane fuel cell and absorption cycle system for power and heating/cooling cogeneration [J].
Guo, Xinru ;
Zhang, Houcheng ;
Zhao, Jiapei ;
Wang, Fu ;
Wang, Jiatang ;
Miao, He ;
Yuan, Jinliang .
ENERGY CONVERSION AND MANAGEMENT, 2019, 181 :292-301
[13]   A Review of Recent Developments and Advanced Applications of High-Temperature Polymer Electrolyte Membranes for PEM Fuel Cells [J].
Hooshyari, Khadijeh ;
Amini Horri, Bahman ;
Abdoli, Hamid ;
Fallah Vostakola, Mohsen ;
Kakavand, Parvaneh ;
Salarizadeh, Parisa .
ENERGIES, 2021, 14 (17)
[14]   Compression-assisted absorption refrigeration using ocean thermal energy [J].
Hu, Zheng ;
Wan, Yueru ;
Zhang, Chengbin ;
Chen, Yongping .
RENEWABLE ENERGY, 2022, 186 :755-768
[15]   Proton exchange membrane fuel cells heat recovery opportunities for combined heating/cooling and power applications [J].
Huy Quoc Nguyen ;
Shabani, Bahman .
ENERGY CONVERSION AND MANAGEMENT, 2020, 204 (204)
[16]   Performance analysis of advanced hybrid GAX cycles: HGAX [J].
Kang, YT ;
Hong, H ;
Park, KS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :442-448
[17]   Degradation modeling and operational optimization for improving the lifetime of high-temperature PEM (proton exchange membrane) fuel cells [J].
Kim, Jintae ;
Kim, Minjin ;
Kang, Taegon ;
Sohn, Young-Jun ;
Song, Taewon ;
Choi, Kyoung Hwan .
ENERGY, 2014, 66 :41-49
[18]   Performance of a hybrid system consisting of a high-temperature polymer electrolyte fuel cell and an absorption refrigerator [J].
Lee, Won-Yong ;
Kim, Minjin ;
Sohn, Young-Jun ;
Kim, Seung-Gon .
ENERGY, 2017, 141 :2397-2407
[19]   Power optimization of a combined power system consisting of a high-temperature polymer electrolyte fuel cell and an organic Rankine cycle system [J].
Lee, Won-Yong ;
Kim, Minjin ;
Sohn, Young-Jun ;
Kim, Seung-Gon .
ENERGY, 2016, 113 :1062-1070
[20]   Does renewable energy electricity and economic complexity index help to achieve carbon neutrality target of top exporting countries? [J].
Li, Hai-Shi ;
Geng, Yao-Chen ;
Shinwari, Riazullah ;
Wang Yangjie ;
Rjoub, Husam .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2021, 299