Preclinical Evaluation of a Modular Inner-Branched Stent Graft to Reconstruct the Left Subclavian Artery in Thoracic Endovascular Aortic Repair: Experimental Study in Pigs

被引:0
作者
Jia, Senhao [1 ]
Zhang, Hongpeng [1 ]
Jia, Xin [1 ]
Xiong, Jiang [1 ]
Ma, Xiaohui [1 ]
Xu, Yongle [1 ]
Zhang, Minhong [1 ]
Rong, Dan [1 ]
Guo, Wei [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Vasc & Endovascular Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
inner-branched stent graft; modular; type B aortic dissection; left subclavian artery; thoracic endovascular aortic repair; pig; MANAGEMENT; COVERAGE; FEASIBILITY; SOCIETY; STROKE;
D O I
10.1177/15266028241241921
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: In approximate 40% of thoracic endovascular aortic repair (TEVAR) procedures, the left subclavian artery (LSA) needs to be covered to obtain sufficient proximal sealing zone. To preserve the LSA during the TEVAR for type B aortic dissection (TBAD) adjacent to LSA, our team designed a modular single inner-branched stent graft. This study was performed to evaluate the safety and feasibility of deploying a modular single inner-branched stent graft in a porcine model.Materials and Methods: Modular inner-branched stent grafts were implanted in 14 pigs via right femoral and right carotid arterial access. Computed tomography angiography (CTA) and angiography were performed in all pigs to appraise the morphological characteristics of the stent grafts at the end of follow-up. The pigs were then euthanized, and tissues were collected for gross and histological examination.Results: The technical success rate was 100% (14/14). One pig suddenly died 5 hours after operation, and 1 pig died after completing the follow-up CTA. During the follow-up period, all surviving pigs showed good mental state, normal diets and activities. Computed tomography angiography examinations showed that all stent grafts were intact without fracture. All bridging covered stents were patent. Angiography showed that the position, shape, and adhesion of the stent grafts were good, and no obvious endoleaks were found. Histological examination showed that the biocompatibility of the stent grafts was good.Conclusions: This study's outcomes demonstrate that it is safe and feasible to deploy a modular single inner-branched stent graft in a porcine model.Clinical Impact This device is the first modular device designed to treat TBAD adjacent to LSA in China. This device is a modular two-component system consisting of aAnchor Anchorthoracic aortic stent graft with a Anchorretrograde inner branch and a Anchorbridging covered stent. The modular design and the retrograde inner branch are the two important innovations of this device. Theoretically, the device could make it easier and safer for clinicians to treat TBAD adjacent to the LSA.
引用
收藏
页数:9
相关论文
共 15 条
[1]   Left subclavian artery coverage during thoracic endovascular aortic repair and risk of perioperative stroke or death [J].
Chung, Jayer ;
Kasirajan, Karthikeshwar ;
Veeraswamy, Ravi K. ;
Dodson, Thomas F. ;
Salam, Atef A. ;
Chaikof, Elliot L. ;
Corriere, Matthew A. .
JOURNAL OF VASCULAR SURGERY, 2011, 54 (04) :979-984
[2]   Evaluation of the Gore TAG thoracic branch endoprosthesis in the treatment of proximal descending thoracic aortic aneurysms [J].
Dake, Michael D. ;
Fischbein, Michael P. ;
Bavaria, Joseph E. ;
Desai, Nimesh D. ;
Oderich, Gustavo ;
Singh, Michael J. ;
Fillinger, Mark ;
Suckow, Bjoern D. ;
Matsumura, Jon S. ;
Patel, Himanshu J. .
JOURNAL OF VASCULAR SURGERY, 2021, 74 (05) :1483-+
[3]   Further Consideration for Subclavian Revascularization with TEVAR [J].
Garg, Karan ;
Maldonado, Thomas S. .
SEMINARS IN VASCULAR SURGERY, 2012, 25 (04) :232-237
[4]   Endovascular Repair of Aortic Dissection Involving the Left Subclavian Artery by Castor Stent Graft: A Multicentre Prospective Trial [J].
Jing, Zaiping ;
Lu, Qingsheng ;
Feng, Jiaxuan ;
Zhou, Jian ;
Feng, Rui ;
Zhao, Zhiqing ;
Bao, Junmin ;
Jiang, Weiliang ;
Zhang, Xiwei ;
Shu, Chang ;
Fu, Weiguo ;
Liu, Changjian ;
Guo, Wei ;
Zhang, Xiaoming ;
Chen, Zhong ;
Liu, Changwei ;
Han, Xinwei .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 60 (06) :854-861
[5]   Chimney Grafts in Aortic Stent Grafting: Hazardous or Useful Technique? Systematic Review of Current Data [J].
Lindblad, B. ;
Bin Jabr, A. ;
Holst, J. ;
Malina, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (06) :722-731
[6]   Chimney Technique for Aortic Arch Pathologies: An 11-Year Single-Center Experience [J].
Mangialardi, Nicola ;
Serrao, Eugenia ;
Kasemi, Holte ;
Alberti, Vittorio ;
Fazzini, Stefano ;
Ronchey, Sonia .
JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (02) :312-323
[7]   The Society for Vascular Surgery Practice Guidelines: Management of the left subclavian artery with thoracic endovascular aortic repair [J].
Matsumura, Jon S. ;
Lee, W. Anthony ;
Mitchell, R. Scott ;
Farber, Mark A. ;
Murad, Mohammad Hassan ;
Lumsden, Alan B. ;
Greenberg, Roy K. ;
Safi, Hazim J. ;
Fairman, Ronald M. .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (05) :1155-1158
[8]   Branched Endovascular Therapy of the Distal Aortic Arch: Preliminary Results of the Feasibility Multicenter Trial of the Gore Thoracic Branch Endoprosthesis [J].
Patel, Himanshu J. ;
Dake, Michael D. ;
Bavaria, Joseph E. ;
Singh, Michael J. ;
Filinger, Mark ;
Fischbein, Michael P. ;
Williams, David M. ;
Matsumura, Jon S. ;
Oderich, Gustavo .
ANNALS OF THORACIC SURGERY, 2016, 102 (04) :1190-1198
[9]   Management of the left subclavian artery and neurologic complications after thoracic endovascular aortic repair [J].
Patterson, Benjamin O. ;
Holt, Peter J. ;
Nienaber, Christoph ;
Fairman, Ronald M. ;
Heijmen, Robin H. ;
Thompson, Matt M. .
JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) :1491-1497
[10]   Editor's Choice - Management of Descending Thoracic Aorta Diseases Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS) [J].
Riambau, V. ;
Boeckler, D. ;
Brunkwall, J. ;
Cao, P. ;
Chiesa, R. ;
Coppi, G. ;
Czerny, M. ;
Fraedrich, G. ;
Haulon, S. ;
Jacobs, M. J. ;
Lachat, M. L. ;
Moll, F. L. ;
Setacci, C. ;
Taylor, P. R. ;
Thompson, M. ;
Trimarchi, S. ;
Verhagen, H. J. ;
Verhoeven, E. L. ;
Kolh, P. ;
de Borst, G. J. ;
Chakfe, N. ;
Debus, E. S. ;
Hinchliffe, R. J. ;
Kakkos, S. ;
Koncar, I. ;
Lindholt, J. S. ;
Vega de Ceniga, M. ;
Vermassen, F. ;
Verzini, F. ;
Kolh, P. ;
Black, J. H., III ;
Busund, R. ;
Bjorck, M. ;
Dake, M. ;
Dick, F. ;
Eggebrecht, H. ;
Evangelista, A. ;
Grabenwoeger, M. ;
Milner, R. ;
Naylor, A. R. ;
Ricco, J. -B. ;
Rousseau, H. ;
Schmidli, J. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 53 (01) :4-52