The SNR of time-of-flight positron emission tomography data for joint reconstruction of the activity and attenuation images

被引:0
作者
Nuyts, Johan [1 ,2 ]
Defrise, Michel [3 ]
Morel, Christian [4 ]
Lecoq, Paul [5 ]
机构
[1] Univ Leuven, Dept Imaging & Pathol, KU Leuven, Nucl Med & Mol imaging, B-3000 Leuven, Belgium
[2] Med Imaging Res Ctr MIRC, B-3000 Leuven, Belgium
[3] Vrije Univ Brussel, Dept Nucl Med, B-1090 Brussels, Belgium
[4] Aix Marseille Univ, CNRS, IN2P3, CPPM, Marseille, France
[5] Univ Politecn Valencia, Valencia, Spain
关键词
SNR; positron emission tomography; reconstruction; variance; PET; LIKELIHOOD; RESOLUTION;
D O I
10.1088/1361-6560/ad078c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Measurement of the time-of-flight (TOF) difference of each coincident pair of photons increases the effective sensitivity of positron emission tomography (PET). Many authors have analyzed the benefit of TOF for quantification and hot spot detection in the reconstructed activity images. However, TOF not only improves the effective sensitivity, it also enables the joint reconstruction of the tracer concentration and attenuation images. This can be used to correct for errors in CT- or MR-derived attenuation maps, or to apply attenuation correction without the help of a second modality. This paper presents an analysis of the effect of TOF on the variance of the jointly reconstructed attenuation and (attenuation corrected) tracer concentration images. Approach. The analysis is performed for PET systems that have a distribution of possibly non-Gaussian TOF-kernels, and includes the conventional Gaussian TOF-kernel as a special case. Non-Gaussian TOF-kernels are often observed in novel detector designs, which make use of two (or more) different mechanisms to convert the incoming 511 keV photon to optical photons. The analytical result is validated with a simple 2D simulation. Main results. We show that if two different TOF-kernels are equivalent for image reconstruction with known attenuation, then they are also equivalent for joint reconstruction of the activity and the attenuation images. The variance increase in the activity, caused by also jointly reconstructing the attenuation image, vanishes when the TOF-resolution approaches perfection. Significance. These results are of interest for PET detector development and for the development of stand-alone PET systems.
引用
收藏
页数:15
相关论文
共 42 条
  • [1] Arino-Estrada G, 2021, IEEE T RADIAT PLASMA, V5, P630, DOI [10.1109/TRPMS.2020.3024032, 10.1109/trpms.2020.3024032]
  • [2] MODEL OBSERVERS FOR ASSESSMENT OF IMAGE QUALITY
    BARRETT, HH
    YAO, J
    ROLLAND, JP
    MYERS, KJ
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (21) : 9758 - 9765
  • [3] Attenuation correction in emission tomography using the emission data-A review
    Berker, Yannick
    Li, Yusheng
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 807 - 832
  • [4] Detection performance analysis for time-of-flight PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) : 6931 - 6950
  • [5] Activity and attenuation reconstruction for positron emission tomography using emission data only via maximum likelihood and iterative data refinement
    Crepaldi, Fabiana
    De Pierro, Alvaro R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 100 - 106
  • [6] De Pierro AR, 2006, COMPUT APPL MATH, V25, P205, DOI 10.1590/S1807-03022006000200006
  • [7] Time-of-flight PET data determine the attenuation sinogram up to a constant
    Defrise, Michel
    Rezaei, Ahmadreza
    Nuyts, Johan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (04) : 885 - 899
  • [8] Defrise Michel, 2016, IEEE NUCL SCI S MEDI
  • [9] Efthimiou N, 2021, IEEE T RADIAT PLASMA, V5, P703, DOI [10.1109/trpms.2020.3048642, 10.1109/TRPMS.2020.3048642]
  • [10] Randoms and TOF gain revisited
    Eriksson, Lars
    Conti, Maurizio
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04) : 1613 - 1623