Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures

被引:2
作者
Ho, Tsung-Yu [1 ,2 ]
Hsu, Cheng-En [3 ,4 ]
Wang, Wei-Chih [2 ,5 ]
Ting, Yen-Nien [6 ]
Tsai, Ming-Tzu [7 ]
Chiu, Yung-Cheng [1 ,2 ,10 ]
Hsu, Jui-Ting [8 ,9 ]
机构
[1] China Med Univ, Sch Med, Taichung, Taiwan
[2] China Med Univ Hosp, Dept Orthoped Surg, Taichung, Taiwan
[3] Taichung Vet Gen Hosp, Dept Orthopaed, Taichung, Taiwan
[4] Tunghai Univ, Bachelors Degree Complet Program, Sports Recreat & Hlth Management Continuing Studie, Taichung, Taiwan
[5] China Med Univ, Hsinchu Hosp, Dept Orthoped Surg, Hsinchu, Taiwan
[6] China Med Univ Hosp, Printing Med Res Ctr 3D, Taichung, Taiwan
[7] Hungkuang Univ, Dept Biomed Engn, Taichung, Taiwan
[8] China Med Univ, Dept Biomed Engn, Taichung, Taiwan
[9] China Med Univ, Sch Dent, Taichung, Taiwan
[10] China Med Univ, Sch Med, Taichung 40402, Taiwan
关键词
bone plate; dorsal side; metacarpal neck fracture; volar side; SHAFT FRACTURES; PHALANGEAL FRACTURES; INTERNAL-FIXATION; SCREW; WIRES;
D O I
10.1097/MD.0000000000034981
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Metacarpal neck fracture is one of the most common types of hand fractures; the literature suggests that applying a bone plate on the dorsal side provides higher fixation strength than that provided by other fixation methods. However, bone plate fixation on the dorsal side may result in postoperative tendon adhesion. So far, no studies have investigated the fixation of metacarpal neck fractures on the volar side by using a bone plate. The objective of this study was to investigate the differences in the fixation results between bone plate fixation on the dorsal side and bone plate fixation on the volar side of the metacarpal in the case of a metacarpal neck fracture. A saw blade was used to create a transverse metacarpal neck fracture on 14 artificial metacarpal bone specimens. The specimens were divided into 2 groups depending on the fixation method: a volar locking plate (VLP) group and a dorsal locking plate (DLP) group. All specimens were subjected to a cantilever bending test on a material testing system, and a force-displacement curve was used to measure the yield force and stiffness, which served as an indicator of the fixation ability of the 2 fracture fixation methods. For the experimental results, the Mann-Whitney U test was used to compare the fixation abilities of the 2 fixation methods. In terms of yield force, the DLP group (266.9 +/- 68.3 N) scored significantly higher than the VLP group (32.6 +/- 2.7 N) (P <.05); expressed in terms of median, the DLP group scored 8.2 times higher than the VLP group. Similarly, in terms of stiffness, the DLP group (69.0 +/- 13.4 N/mm, median +/- interquartile range) scored significantly higher than the VLP group (12.9 +/- 1.4 N/mm) (P <.05); expressed in terms of median, the DLP group scored 5.3 times higher than the VLP group. The fixation strength of volar bone plates is only about one-third of that of dorsal bone plates.
引用
收藏
页数:7
相关论文
共 40 条
[11]   Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone [J].
Chiu, Yung-Cheng ;
Hsu, Cheng-En ;
Ho, Tsung-Yu ;
Ting, Yen-Nien ;
Tsai, Ming-Tzu ;
Hsu, Jui-Ting .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[12]   New fixation approach for transverse metacarpal neck fracture: a biomechanical study [J].
Chiu, Yung-Cheng ;
Tsai, Ming-Tzu ;
Hsu, Cheng-En ;
Hsu, Horng-Chaung ;
Huang, Heng-Li ;
Hsu, Jui-Ting .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
[13]   Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs [J].
Curtis, Benjamin D. ;
Fajolu, Olukemi ;
Ruff, Michael E. ;
Litsky, Alan S. .
ORTHOPAEDIC SURGERY, 2015, 7 (03) :256-260
[14]   Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures [J].
Doht, Stefanie ;
Meffert, Rainer H. ;
Raschke, Michael J. ;
Blunk, Torsten ;
Ochman, Sabine .
SCIENTIFIC WORLD JOURNAL, 2014,
[15]  
Dreyfuss Daniel, 2019, Hand (N Y), V14, P27, DOI 10.1177/1558944718798854
[16]   Fifth metacarpal neck fracture fixation: Locking plate versus K-wire? [J].
Facca, S. ;
Ramdhian, R. ;
Pelissier, A. ;
Diaconu, M. ;
Liverneaux, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) :506-512
[17]   Incidence and demographics of hand fractures in British Columbia, Canada: A population-based study [J].
Feehan, Lynne M. ;
Sheps, Samuel B. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (07) :1068-1074
[18]   Biomechanical Comparison of Double-Row Locking Plates Versus Single- and Double-Row Non-Locking Plates in a Comminuted Metacarpal Fracture Model [J].
Gajendran, Varun K. ;
Szabo, Robert M. ;
Myo, George K. ;
Curtiss, Shane B. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (10) :1851-1858
[19]   Open reduction and internal fixation versus percutaneous transverse Kirschner wire fixation for single, closed second to fifth metacarpal shaft fractures: a systematic review [J].
Greeven, A. P. A. ;
Bezstarosti, S. ;
Krijnen, P. ;
Schipper, I. B. .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2016, 42 (02) :169-175
[20]   The curative effect analysis of a modified Kirschner wires and locking plate internal fixation method for the fifth metacarpal neck fracture [J].
Gu, Song ;
Zhou, Long ;
Huang, Yinjun ;
Xie, Renguo .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)