Aptamer-based fluorescent sensor for highly sensitive detection of methamphetamine

被引:4
|
作者
Wang, Yandan [1 ,2 ,3 ]
Wang, Zheyu [1 ,2 ,3 ]
Tong, Yishuo [1 ,2 ,3 ]
Zhang, Dan [1 ,2 ,3 ]
Yun, Keming [1 ,2 ,3 ]
Yan, Jiangwei [1 ,2 ,3 ,4 ]
Niu, Weifen [1 ,2 ,3 ,4 ]
机构
[1] Shanxi Med Univ, Sch Forens Med, Jinzhong, Shanxi, Peoples R China
[2] Shanxi Key Lab Forens Med, Jinzhong, Shanxi, Peoples R China
[3] Key Lab Forens Toxicol, Minist Publ Secur, Jinzhong, Shanxi, Peoples R China
[4] Shanxi Med Univ, Sch Forens Med, Jinzhong 030600, Shanxi, Peoples R China
关键词
binding active site; fluorescent aptasensor; graphene oxide (GO); methamphetamine (METH); IN-VITRO SELECTION; PHASE MICROEXTRACTION; ORAL FLUID; AMPHETAMINE; METHYLAMPHETAMINE; NANOPARTICLES; BIOSENSORS; ASSAY;
D O I
10.1002/bio.4687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a fluorescence aptamer sensor was achieved by employing the fundamental principle of fluorescence resonance energy transfer. By employing molecular modeling technologies to identify the binding site, the high-affinity aptamer APT-40nt was derived from the whole sequence and utilized on the graphene oxide (GO) fluorescent platform for the purpose of achieving a highly sensitive detection of methamphetamine (METH). The aptamer tagged with fluorescein (FAM) dye undergoes quenching in the presence of GO due to pi-stacking interaction. With the addition of the target, the aptamer that has been tagged was detached from the GO surface, forming a stable complex with METH. This process resulted in fluorescence restoration of the system, and the degree of fluorescence restoration was proportional to METH concentration in the linear range of 1-50 and 50-200 nM. Notably, under optimized conditions, the detection limit of this aptasensor was as low as 0.78 nM, which meets the detection limit requirements of METH detection in saliva and urine in some countries and regions. Moreover, other common illicit drugs and metabolites had minimizing interference with the determination. The established aptasensor, therefore, has been successfully applied to detect METH in saliva and urine samples and exhibited satisfactory recoveries (87%-111%). This aptasensor has the advantages of low detection limit, excellent selectivity, ease of operation, and low cost, providing a promising strategy for on-site detection of METH in saliva and urine. A straightforward, selective, and low-cost fluorescence aptamer sensor based on graphene oxide (GO) as a fluorescence quencher for highly sensitive detection of methamphetamine (METH) was developed. The aptasensor has a low detection limit (0.78 nM) and excellent selectivity, which has been successfully applied to detect METH in saliva and urine samples. image
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Aptamer-Based Fluorescent Switch for Sensitive Detection of Oxytetracycline
    Babaei, Mahsa
    Jalalian, Seyed Hamid
    Bakhtiari, Hadi
    Ramezani, Mohammad
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2017, 70 (06) : 718 - 723
  • [2] Enzyme-aided amplification strategy for sensitive detection of methamphetamine based on fluorescence aptamer sensor
    Wang, Zheyu
    Wang, Yandan
    Tong, Yishuo
    Niu, Weifen
    ANALYTICAL SCIENCES, 2024, 40 (12) : 2125 - 2132
  • [3] Aptamer-based Electrochemical Sensor for the Detection of Ampicillin
    Feier, B.
    Bajan, I.
    Cristea, C.
    Sandulescu, R.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2016, 2017, 59 : 107 - 110
  • [4] Luminescent Aptamer-Based Bioassays for Sensitive Detection of Food Allergens
    Calabria, Donato
    Zangheri, Martina
    Pour, Seyedeh Rojin Shariati
    Trozzi, Ilaria
    Pace, Andrea
    Lazzarini, Elisa
    Calabretta, Maria Maddalena
    Mirasoli, Mara
    Guardigli, Massimo
    BIOSENSORS-BASEL, 2022, 12 (08):
  • [5] Aptamer-based fluorescent sensors for the detection of cancer biomarkers
    Zhao, Xuhua
    Dai, Xiaochun
    Zhao, Suya
    Cui, Xiaohua
    Gong, Tao
    Song, Zhiling
    Meng, Hongmin
    Zhang, Xiaobing
    Yu, Baofeng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 247
  • [6] Aptamer-Based Fluorescent Biosensors
    Wang, R. E.
    Zhang, Y.
    Cai, J.
    Cai, W.
    Gao, T.
    CURRENT MEDICINAL CHEMISTRY, 2011, 18 (27) : 4175 - 4184
  • [7] Highly sensitive protein detection by aptamer-based single-molecule kinetic fingerprinting
    Chatterjee, Tanmay
    Johnson-Buck, Alexander
    Walter, Nils G.
    BIOSENSORS & BIOELECTRONICS, 2022, 216
  • [8] Sensitive and Homogeneous Detection System with Aptamer-Based Biosensor
    Tsukakoshi, Kaori
    Ikebukuro, Kazunori
    SENSORS AND MATERIALS, 2016, 28 (10) : 1083 - 1089
  • [9] Aptamer-based Upconversion Fluorescence Sensor for Doxorubicin Detection
    Mo, Jingwen
    Wang, Shichang
    Zeng, Jiaying
    Ding, Xiong
    JOURNAL OF FLUORESCENCE, 2023, 33 (05) : 1897 - 1905
  • [10] Carbon dots-thionine modified aptamer-based biosensor for highly sensitive cocaine detection
    Azizi, Sajad
    Gholivand, Mohammad Bagher
    Amiri, Masoud
    Manouchehri, Iraj
    Moradian, Rostam
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 907