Effect of Local Floor Heating System on Occupants' Thermal Comfort and Energy Consumption Using Computational Fluid Dynamics (CFD)

被引:1
作者
Dakkama, Hassan J. [1 ]
Khaleel, Ahmed Jawad [1 ]
Ahmed, Ahmed Qasim [1 ]
Al-Shohani, Wisam A. M. [1 ]
Obaida, Hayder M. B. [1 ]
机构
[1] Middle Tech Univ, Tech Engn Coll, Dept Mech Power Engn, Baghdad 10074, Iraq
关键词
underfloor air distribution; local heating; CFD; energy saving; thermal comfort; DISTRIBUTION UFAD SYSTEM; RADIANT FLOOR; AIR-FLOW; TEMPERATURE DISTRIBUTION; ROOM; MODEL; PUMP;
D O I
10.3390/fluids8110299
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In this article, the influence of splitting a local underfloor air distribution system (UFAD) on indoor thermal comfort for three occupants was studied numerically. A validated computational fluid dynamics (CFD) model was employed in this investigation. The proposed heating system was evaluated and analyzed for different values of air temperature and supply velocity. Providing suitable thermal comfort and saving energy are considered the main evaluation indexes for this study. Three cases, cases 2, 3, and 4, of the proposed local UFAD system were compared with a traditional heating system case, case 1. The supplying air velocity and air temperature in the reference case were 0.5 m/s and 29 degrees C, while in cases 2, 3, and 4, they were 0.4 m/s and 29 degrees C, 28 degrees C, and 27 degrees C, respectively. The results show that acceptable indoor human thermal comfort and energy demand reduction were achieved by using the splitting UFAD concept.
引用
收藏
页数:17
相关论文
共 32 条
[11]   Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system [J].
Heidarinejad, Ghassem ;
Fathollahzadeh, Mohammad Hassan ;
Pasdarshahri, Hadi .
ENERGY AND BUILDINGS, 2015, 97 :155-161
[12]   Modelling conjugate flow and heat transfer in a ventilated room for indoor thermal comfort assessment [J].
Horikiri, Kana ;
Yao, Yufeng ;
Yao, Jun .
BUILDING AND ENVIRONMENT, 2014, 77 :135-147
[13]   Price-responsive model predictive control of floor heating systems for demand response using building thermal mass [J].
Hu, Maomao ;
Xiao, Fu ;
Jorgensen, John Bagterp ;
Li, Rongling .
APPLIED THERMAL ENGINEERING, 2019, 153 :316-329
[14]   Effect of warm air supplied facially on occupants' comfort [J].
Kaczmarczyk, J. ;
Melikov, A. ;
Sliva, D. .
BUILDING AND ENVIRONMENT, 2010, 45 (04) :848-855
[15]   EFFECT OF EXHAUST LAYOUT ON THE INDOOR THERMAL COMFORT UNDER HARSH WEATHER CONDITIONS [J].
Khaleel, Ahmed Jawad ;
Ahmed, Ahmed Qasim ;
Dakkama, Hassan J. ;
Al-Shohani, Vvisam A. M. .
JOURNAL OF THERMAL ENGINEERING, 2021, 7 (01) :148-160
[16]   Thermal comfort prediction of an underfloor air distribution system in a large indoor environment [J].
Kim, Gon ;
Schaefer, Laura ;
Lim, Tae Sub ;
Kim, Jeong Tai .
ENERGY AND BUILDINGS, 2013, 64 :323-331
[17]   Analytical solution for heat transfer in a multilayer floor of a radiant floor system [J].
Li, Qing-qing ;
Chen, Chao ;
Zhang, Ye ;
Lin, Jie ;
Ling, Hao-shu ;
Ma, Yun .
BUILDING SIMULATION, 2014, 7 (03) :207-216
[18]   Investigation on a solar-groundwater heat pump unit associated with radiant floor heating [J].
Ma, Hongting ;
Li, Cong ;
Lu, Wenqian ;
Zhang, Zeyu ;
Yu, Shaojie ;
Du, Na .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 75 :972-977
[19]   Radiant ceiling panel heating-cooling systems: experimental and simulated study of the performances, thermal comfort and energy consumptions [J].
Miriel, J ;
Serres, L ;
Trombe, A .
APPLIED THERMAL ENGINEERING, 2002, 22 (16) :1861-1873
[20]   2-DIMENSIONAL SIMULATION OF AIR-FLOW AND THERMAL COMFORT IN A ROOM WITH OPEN-WINDOW AND INDOOR COOLING SYSTEMS [J].
NIU, J ;
VANDERKOOI, J .
ENERGY AND BUILDINGS, 1992, 18 (01) :65-75