Three-Dimensional Finger Test: A New Echocardiographic Method to Locate the Best Access Site During NeoChord Procedure

被引:0
作者
Vairo, Alessandro [1 ,4 ]
Manai, Rossella [1 ]
Gaiero, Lorenzo [1 ]
Desalvo, Paolo [1 ]
Bellettini, Matteo [1 ]
Zaccaro, Lorenzo [1 ]
Rinaudo, Andrea [1 ]
Franchin, Luca [1 ]
Piroli, Francesco [1 ]
Bruno, Francesco [1 ]
Sebastiano, Viviana [2 ]
Stura, Erik Cura [2 ]
Barbero, Cristina [2 ]
Marro, Matteo [2 ]
Faletti, Riccardo [3 ]
Alunni, Gianluca [1 ]
De Ferrari, Gaetano Maria [1 ]
Rinaldi, Mauro [2 ]
Salizzoni, Stefano [2 ]
机构
[1] Univ Turin, Citta Salute & Sci Torino, Dept Med Sci, Div Cardiol, Turin, Italy
[2] Univ Turin, Citta Salute & Sci Torino, Dept Surg Sci, Div Cardiac Surg, Turin, Italy
[3] Univ Turin, Citta Salute & Sci Torino, Div Radiol, Turin, Italy
[4] Univ Torino, San Giovanni Battista Molinette Hosp, Corso Bramante 88-90, I-10126 Turin, Italy
关键词
three-dimensional transesophageal echocardiography; mitral valve prolapse; mitral valve regurgitation; beating-heart mitral valve repair; IMPLANTATION;
D O I
10.1177/15569845231185346
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Transventricular beating- heart mitral valve repair (TBMVR) with artificial chordae implantation is a technique to treat mitral valve prolapse. Two-dimensional (2D) echocardiography completed with simultaneous biplane view during surgeon finger pushing on the left ventricular (LV) wall (finger test [FT]) is currently used to localize the desired LV access, on the inferior-lateral wall, between the papillary muscles (PMs). We aimed to compare a new three-dimensional (3D) method with conventional FT in terms of safety and better localization of LV access. Methods: During TBMVR, conventional FT was completed using 3D transesophageal echocardiography by placing the sample box in the bicommissural view of the LV, including the PMs and the apex. The 3D volume was subsequently edited to visualize the LV from above (surgical view) to localize the bulge of the operator's finger pushing on the LV. We asked the first operator, the second operator, and the cardiac surgery fellow, separately, to evaluate the location of their finger pushing, both with the 2D method and the 3D method, to estimate the interoperator concordance. Results: From 2019 to 2021, 42 TBMVRs were performed without complications related to access using FT completed with the 3D method. Regarding the choice of the right and safe entry site, the operator's agreement was higher using 3D rendering compared with conventional FT (mean agreement 0.59 +/- 0.29 for 2D vs 0.83 +/- 0.20 for 3D), while full operator agreement was 10 of 42 for 2D and 23 of 42 for 3D (P = 0.004). Conclusions: Three-dimensional FT is easy to perform and facilitates surgeons choosing the best access for TBMVR in term of anatomical localization and safety.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 8 条
[1]   An early European experience with transapical off-pump mitral valve repair with NeoChord implantation [J].
Colli, Andrea ;
Manzan, Erica ;
Aidietis, Audrius ;
Rucinskas, Kestutis ;
Bizzotto, Eleonora ;
Besola, Laura ;
Pradegan, Nicola ;
Pittarello, Demetrio ;
Janusauskas, Vilius ;
Zakarkaite, Diana ;
Drasutiene, Agne ;
Lipnevicius, Arturas ;
Danner, Bernhard C. ;
Sievert, Horst ;
Vaskelyte, Laura ;
Schnelle, Nalan ;
Salizzoni, Stefano ;
Marro, Massimo ;
Rinaldi, Mauro ;
Kurnicka, Katarzyna ;
Wrobel, Kristof ;
Ceffarelli, Mariano ;
Savini, Carlo ;
Pacini, Davide ;
Gerosa, Gino .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (03) :460-466
[2]   Transapical off-pump mitral valve repair with Neochord Implantation (TOP-MINI): step-by-step guide [J].
Colli, Andrea ;
Zucchetta, Fabio ;
Torregrossa, Gianluca ;
Manzan, Erica ;
Bizzotto, Eleonora ;
Besola, Laura ;
Bellu, Roberto ;
Sarais, Cristiano ;
Pittarello, Demetrio ;
Gerosa, Gino .
ANNALS OF CARDIOTHORACIC SURGERY, 2015, 4 (03) :295-297
[3]  
Dean AG, 2013, OpenEpi: open source epidemiologic statistics for public health
[4]   Good 5-Year Durability of Transapical Beating Heart Off-Pump Mitral Valve Repair With Neochordae [J].
Kiefer, Philipp ;
Meier, Sabine ;
Noack, Thilo ;
Borger, Michael Andrew ;
Ender, Joerg ;
Hoyer, Alexandro ;
Mohr, Friedrich Wilhelm ;
Seeburger, Joerg ;
Gerosa, Gino .
ANNALS OF THORACIC SURGERY, 2018, 106 (02) :440-446
[5]   Off-Pump Transapical Implantation of Artificial Neo-Chordae to Correct Mitral Regurgitation [J].
Seeburger, Joerg ;
Rinaldi, Mauro ;
Nielsen, Sten Lyager ;
Salizzoni, Stefano ;
Lange, Ruediger ;
Schoenburg, Markus ;
Alfieri, Ottavio ;
Borger, Michael Andrew ;
Mohr, Friedrich Wilhelm ;
Aidietis, Audrius .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (09) :914-919
[6]   Use of a photo-realism 3D rendering technique to enhance echocardiographic visualization of the anatomical details during beating-heart mitral valve repair [J].
Vairo, Alessandro ;
Marro, Matteo ;
De Ferrari, Gaetano Maria ;
Rinaldi, Mauro ;
Salizzoni, Stefano .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (11) :2090-2093
[7]   "The Starry Sky." A new intraprocedural three-dimensional echocardiographic technique [J].
Vairo, Alessandro ;
Marro, Matteo ;
Speziali, Giovanni ;
Rinaldi, Mauro ;
Salizzoni, Stefano .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (09) :1765-1768
[8]   Three-Dimensional Echocardiography: Current Status and Real-Life Applications [J].
Wu, Victor Chien-Chia ;
Takeuchi, Masaaki .
ACTA CARDIOLOGICA SINICA, 2017, 33 (02) :107-118