Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens

被引:10
作者
Al-Amri, Saad Abdulrahman J. [1 ,2 ,3 ]
Alio, Jorge L. [1 ,3 ]
Milan-Castillo, Roberto [1 ]
D'Oria, Francesco [1 ,4 ]
Martinez-Abad, Antonio [1 ]
Yebana, Pilar [1 ]
Subirana, Nuria [1 ]
Al-Harbi, Ziyad [1 ,5 ]
Plaza-Puche, Ana B. [1 ]
Alio del Barrio, Jorge L. [1 ,3 ]
机构
[1] VISSUM Miranza Grp, Cornea Cataract & Refract Surg Unit, Alicante, Spain
[2] Prince Sultan Med Mil City, Dept Ophthalmol, Riyadh, Saudi Arabia
[3] Univ Miguel Hernandez, Dept Ophthalmol, Alicante, Spain
[4] Univ Bari, Sect Ophthalmol, Dept Basic Med Sci Neurosci & Sense Organs, Bari, Italy
[5] Al Nakheel Med Ctr, Riyadh, Saudi Arabia
关键词
PATIENT SATISFACTION; IOL DESIGNS; OUTCOMES; RANGE;
D O I
10.3928/1081597X-20221130-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. METHODS: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). RESULTS: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 +/- 0.12 and 0.31 +/- 0.07, respectively), followed by the AcrySof SA60AT (0.39 +/- 0.10 and 0.27 +/- 0.07) and AcrySof IQ Vivity (0.34 +/- 0.11 and 0.24 +/- 0.09) (P <.001). The AcrySof IQ Vivity and monofocal IOLs were comparable (P >.05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 +/- 0.06 at 3 mm; P <.001) compared to the monofocal AcrySof SA60AT (0.24 +/- 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 +/- 0.06 at 3 mm) groups. The PSF with LOA was comparable (P >.05) among the three groups at both the 3and 4-mm pupil size. CONCLUSIONS: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and monofocal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA).
引用
收藏
页码:103 / +
页数:9
相关论文
共 30 条
  • [1] Extended depth of focus intraocular lenses for presbyopia
    Akella, Sruti S.
    Juthani, Viral V.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) : 319 - 323
  • [2] Ali J., 2019, MULTIFOCAL INTRAOCUL, P53, DOI DOI 10.1007/978-3-030-21282-7_5
  • [3] Retinal image quality after microincision intraocular lens implantation
    Alió, JL
    Schimchak, P
    Montés-Micó, R
    Galal, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) : 1557 - 1560
  • [4] Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry
    Alio, Jorge L.
    D'Oria, Francesco
    Toto, Francesca
    Balgos, Joan
    Palazon, Antonio
    Versaci, Francesco
    Alio del Barrio, Jorge L.
    [J]. EYE AND VISION, 2021, 8 (01)
  • [5] Presbyopic Lenses: Evidence, Masquerade News, and Fake News
    Alio, Jorge L.
    [J]. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (04): : 273 - 274
  • [6] Visual Strehl Performance of IOL Designs with Extended Depth of Focus
    Arias Gallego, Augusto
    Bara, Salvador
    Jaroszewicz, Zbigniew
    Kolodziejczyk, Andrzej
    [J]. OPTOMETRY AND VISION SCIENCE, 2012, 89 (12) : 1702 - 1707
  • [7] Bala C, 2020, AM SOC CAT REFR SURG
  • [8] Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus
    Boehm, Myriam
    Petermann, Kerstin
    Hemkeppler, Eva
    Kohnen, Thomas
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) : 1625 - 1636
  • [9] Borkenstein Andreas F, 2021, Biomed Hub, V6, P77, DOI 10.1159/000519139
  • [10] Intraocular lens optics and aberrations
    Chang, Daniel H.
    Rocha, Karolinne M.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (04) : 298 - 303