Point-of-care detection of glycated hemoglobin using a novel dry chemistry-based electrochemiluminescence device

被引:4
作者
Zhou, Xinya [1 ,2 ,3 ]
Lai, Wei [1 ,2 ,3 ]
Zhong, Jinbiao [1 ,2 ,3 ]
Yang, Yang [1 ,2 ,3 ]
Chen, Zhenyu [4 ]
Zhang, Chunsun [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[2] South China Normal Univ, Inst Laser Life Sci, Coll Biophoton, Guangzhou 510631, Peoples R China
[3] South China Normal Univ, Coll Biophoton, Guangdong Prov Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[4] Guangzhou First Peoples Hosp, Nansha Hosp, Guangzhou 511457, Peoples R China
关键词
Enzyme biosensor; Dry chemistry; Three-electrode electrochemiluminescence; Point-of-care testing; Glycated hemoglobin detection; QUANTITATIVE DETECTION; LABEL-FREE; GLUCOSE; HBA1C; ELECTRODE; LUMINOL; ASSAY; IDENTIFICATION; PERFORMANCE; BIOSENSOR;
D O I
10.1016/j.aca.2023.341829
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a good biomarker to reflect the average level of blood glucose, glycated hemoglobin (HbA1c) is mainly used for long-term glycemic monitoring and risk assessment of complications in diabetic patients. Previous analysis methods for HbA1c usually require complex pretreatment processes and large-scale biochemical analyzers, which makes it difficult to realize the point-of-care testing (POCT) of HbA1c. In this work, we have proposed a three-electrode dry chemistry-based electrochemiluminescence (ECL) biosensor and its self-contained automatic ECL analyzer. In this enzymatic biosensor, fructosyl amino-caid oxidase (FAOD) reacts with the hydrolysis product of HbA1c, and the produced hydrogen peroxide further reacts with luminol under the appropriate driving voltage, generating photons to realize the quantitative detection of HbA1c. Under optimized conditions, the biosensors have a good linear response to different concentrations of fructosyl valine (FV) ranging from 0.05 to 2 mM, with a limit of detection of 2 mu M. The within-batch variation is less than 15%, and the biosensors still have 78% of the initial response after the accelerated aging test of 36 h at 37 degrees C. Furthermore, the recoveries for different concentrations of samples in whole blood were within 92.3-99.7%. These results illustrate that the proposed method has the potential for use in POCT of HbA1c.
引用
收藏
页数:9
相关论文
共 56 条
  • [1] Advances in HbA1c Biosensor Development Based on Field Effect Transistors: A Review
    Ahmadi, Anita
    Kabiri, Shima
    Omidfar, Kobra
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (16) : 8912 - 8921
  • [2] Luminol chemiluminescence biosensor for glycated hemoglobin (HbA1c) in human blood samples
    Ahn, Kwang-Soo
    Lee, Jung Hoon
    Park, Jong-Myeon
    Choi, Han Nim
    Lee, Won-Yong
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 75 : 82 - 87
  • [3] Amer Diabet Assoc, 2014, DIABETES CARE, V37, pS81, DOI [10.2337/dc11-S062, 10.2337/dc14-S081, 10.2337/dc11-S011, 10.2337/dc12-s064, 10.2337/dc13-S067, 10.2337/dc13-S011, 10.2337/dc10-S062, 10.2337/dc12-s011, 10.2337/dc10-S011]
  • [4] Enzyme inhibition-based biosensors for food safety and environmental monitoring
    Amine, A
    Mohammadi, H
    Bourais, I
    Palleschi, G
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) : 1405 - 1423
  • [5] Quantitative, single-step dual measurement of hemoglobin A1c and total hemoglobin in human whole blood using a gold sandwich immunochromatographic assay for personalized medicine
    Ang, Shu Hwang
    Rambeli, Musalman
    Thevarajah, T. Malathi
    Alias, Yatimah Binti
    Khor, Sook Mei
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 78 : 187 - 193
  • [6] [Anonymous], 2010, Diabetes Care, V33 Suppl 1, pS4, DOI 10.2337/dc10-S004
  • [7] Diabetic Foot Ulcers and Their Recurrence
    Armstrong, David G.
    Boulton, Andrew J. M.
    Bus, Sicco A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2017, 376 (24) : 2367 - 2375
  • [8] Gelatin/Maltodextrin Water-in-Water (W/W) Emulsions for the Preparation of Cross-Linked Enzyme-Loaded Microgels
    Beldengrun, Yoran
    Aragon, Jordi
    Prazeres, Sofia F.
    Montalvo, Gemma
    Miras, J.
    Esquena, Jordi
    [J]. LANGMUIR, 2018, 34 (33) : 9731 - 9743
  • [9] Miniaturized Electrochemiluminescence Platform With Laser-Induced Graphene Electrodes for Multiple Biosensing
    Bhaiyya, Manish
    Rewatkar, Prakash
    Salve, Mary
    Pattnaik, Prasant Kumar
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2021, 20 (01) : 79 - 85
  • [10] FURTHER IDENTIFICATION OF NATURE AND LINKAGE OF CARBOHYDRATE IN HEMOGLOBIN-A1C
    BUNN, HF
    HANEY, DN
    GABBAY, KH
    GALLOP, PM
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1975, 67 (01) : 103 - 109