Allergic contact dermatitis to isobornyl acrylate in a hospital wristband

被引:2
作者
Samaran, Quentin [1 ,2 ,4 ]
Raison-Peyron, Nadia [1 ,2 ]
Dereure, Olivier [1 ,2 ]
Svedman, Cecilia [3 ]
Dahlin, Jakob [3 ]
机构
[1] Montpellier Univ Hosp, Dept Dermatol, Montpellier, France
[2] Montpellier Univ, Montpellier, France
[3] Lund Univ, Skane Univ Hosp, Dept Occupat & Environm Dermatol, Malmo, Sweden
[4] Hop St Eloi, Dept Dermatol, 80 Ave Augustin Fliche, F-34295 Montpellier 5, France
关键词
allergic contact dermatitis; CAS no. 5888-33-5; case report; isobornyl acrylate; patch test; wristband;
D O I
10.1111/cod.14539
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
[No abstract available]
引用
收藏
页码:62 / 64
页数:3
相关论文
共 10 条
[1]   Isobornyl Acrylate [J].
Aerts, Olivier ;
Herman, Anne ;
Mowitz, Martin ;
Bruze, Magnus ;
Goossens, An .
DERMATITIS, 2020, 31 (01) :4-12
[2]  
Bruze M., 2014, PATCH TESTING TIPS R, DOI [10.1007/978-3-642-45395-3, DOI 10.1007/978]
[3]   Intense skin reaction to a new glucose monitoring and insulin pump system [J].
Hamnerius, Nils ;
Mowitz, Martin .
CONTACT DERMATITIS, 2020, 83 (06) :524-527
[4]   ALLERGIC CONTACT-DERMATITIS FROM DI-ISODECYL PHTHALATE IN A POLYVINYL-CHLORIDE IDENTITY BAND [J].
HILLS, RJ ;
IVE, FA .
CONTACT DERMATITIS, 1993, 29 (02) :94-95
[5]   European Society of Contact Dermatitis guideline for diagnostic patch testing - recommendations on best practice [J].
Johansen, Jeanne D. ;
Aalto-Korte, Kristiina ;
Agner, Tove ;
Andersen, Klaus E. ;
Bircher, Andreas ;
Bruze, Magnus ;
Cannavo, Alicia ;
Gimenez-Arnau, Ana ;
Goncalo, Margarida ;
Goossens, An ;
John, Swen M. ;
Liden, Carola ;
Lindberg, Magnus ;
Mahler, Vera ;
Matura, Mihly ;
Rustemeyer, Thomas ;
Serup, Jorgen ;
Spiewak, Radoslaw ;
Thyssen, Jacob P. ;
Vigan, Martine ;
White, Ian R. ;
Wilkinson, Mark ;
Uter, Wolfgang .
CONTACT DERMATITIS, 2015, 73 (04) :195-221
[6]   Allergic contact dermatitis caused by isobornyl acrylate in OmniPod, an innovative tubeless insulin pump [J].
Raison-Peyron, Nadia ;
Mowitz, Martin ;
Bonardel, Nathalie ;
Aerts, Olivier ;
Bruze, Magnus .
CONTACT DERMATITIS, 2018, 79 (02) :76-80
[7]   Allergic contact dermatitis from a disposable blood pressure cuff containing isobornyl acrylate and 2-phenoxyethyl acrylate [J].
Renaudin, Helene ;
Darrigade, Anne-Sophie ;
Dendooven, Ella ;
Foubert, Kenn ;
Aerts, Olivier ;
Milpied, Brigitte .
CONTACT DERMATITIS, 2021, 84 (06) :462-464
[8]  
Sasseville D, 2012, DERMATITIS, V23, P6, DOI 10.1097/DER.0b013e31823d1b81
[9]   Changes in adhesive ingredients in continuous glucose monitoring systems may induce new contact allergy pattern [J].
Svedman, Cecilia ;
Ulriksdotter, Josefin ;
Lejding, Tina ;
Bruze, Magnus ;
Mowitz, Martin .
CONTACT DERMATITIS, 2021, 84 (06) :439-446
[10]   Allergic contact dermatitis caused by 1,6-hexanediol diacrylate in a hospital wristband [J].
van Amerongen, Cynthia C. A. ;
Dahlin, Jakob ;
Isaksson, Marlene ;
Schuttelaar, Marie L. A. .
CONTACT DERMATITIS, 2019, 81 (06) :446-449